Search Legislation

The Bathing Water Regulations 2008

Status:

This is the original version (as it was originally made).

PART 1INTESTINAL ENTEROCOCCI AND ESCHERICHIA COLI

Location of monitoring point

1.  The Agency must—

(a)at every bathing water, locate the monitoring point where most bathers are expected; and

(b)subject to paragraph 7, where possible, take samples 30 centimetres below the water’s surface and in water that is at least one metre deep.

Monitoring calendar

2.—(1) The Agency must—

(a)establish a monitoring calendar for every bathing water before the start of every bathing season; and

(b)take samples at every bathing water no later than four days after the date specified in the monitoring calendar.

(2) In relation to any abnormal situation—

(a)the Agency may suspend the monitoring calendar for the duration of the situation; and

(b)as soon as possible after the end of the situation, the Agency must take sufficient additional samples to replace those missing due to the suspension and to ensure that it has the minimum number required for the bathing water for the bathing season.

Frequency of monitoring

3.  The Agency must—

(a)take and analyse at least four samples from every bathing water in relation to every bathing season;

(b)take the first such sample for every bathing season shortly before the start of that season; and

(c)take samples from every bathing water throughout the bathing season at intervals not exceeding one month.

Sampling equipment

4.—(1) Subject to paragraph 7, the Agency must only use sampling bottles which—

(a)have been—

(i)sterilised in an autoclave for at least 15 minutes at 121 degrees Celsius;

(ii)dry sterilised at no lower than 160 degrees Celsius and no higher than 170 degrees Celsius for at least one hour; or

(iii)irradiated by their manufacturer and not used previously;

(b)are of a size which allows sufficient water to be taken and analysed for the presence of intestinal enterococci and Escherichia coli; and

(c)are made of transparent and colourless material.

(2) The Agency must—

(a)use aseptic techniques to maintain the sterility of the sample bottles; and

(b)clearly identify every sample taken by marking in indelible ink the sample bottle and associated paperwork.

Storage and transport of samples before analysis

5.—(1) Subject to paragraph 7, the Agency must—

(a)at all times, protect every sample taken from exposure to light, and in particular, direct sunlight; and

(b)conserve every sample at a temperature of around 4 degrees Celsius between sampling and laboratory analysis.

(2) In relation to any sample, if the interval between sampling and laboratory analysis is likely to exceed four hours, the Agency must conserve the sample in a refrigerator.

(3) The Agency must ensure that the time between sampling and laboratory analysis does not exceed 24 hours and must use its best endeavours to keep this time as short as possible.

Reference methods of analysis

6.  Subject to paragraph 7, the Agency must use the following reference methods of analysis—

(a)for intestinal enterococci, ISO 7899-1 or ISO 7899-2; and

(b)for Escherichia coli, ISO 9308-3 or ISO 9308-1.

General provisions in relation to rules or reference methods of analysis

7.  The Agency—

(a)must have regard to the guidelines on the handling of samples for microbiological analyses given in Annex V to the Bathing Water Directive; and

(b)may use such rules or reference methods of analysis as it considers are substantively equivalent to those specified in this Schedule, where the Agency has notified the appropriate Minister giving details of such rules and methods and their equivalence.

Back to top

Options/Help

Print Options

Close

Legislation is available in different versions:

Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.

Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.

Close

Opening Options

Different options to open legislation in order to view more content on screen at once

Close

Explanatory Memorandum

Explanatory Memorandum sets out a brief statement of the purpose of a Statutory Instrument and provides information about its policy objective and policy implications. They aim to make the Statutory Instrument accessible to readers who are not legally qualified and accompany any Statutory Instrument or Draft Statutory Instrument laid before Parliament from June 2004 onwards.

Close

More Resources

Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as enacted version that was used for the print copy
  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • correction slips
  • links to related legislation and further information resources
Close

More Resources

Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as made version that was used for the print copy
  • correction slips

Click 'View More' or select 'More Resources' tab for additional information including:

  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • links to related legislation and further information resources