Commission Regulation (EU) No 813/2013 of 2 August 2013 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for space heaters and combination heaters (Text with EEA relevance)
When the UK left the EU, legislation.gov.uk published EU legislation that had been published by the EU up to IP completion day (31 December 2020 11.00 p.m.). On legislation.gov.uk, these items of legislation are kept up-to-date with any amendments made by the UK since then.
Legislation.gov.uk publishes the UK version. EUR-Lex publishes the EU version. The EU Exit Web Archive holds a snapshot of EUR-Lex’s version from IP completion day (31 December 2020 11.00 p.m.).
This is the original version as it was originally adopted in the EU.
This legislation may since have been updated - see the latest available (revised) version
From 26 September 2015 the seasonal space heating energy efficiency and useful efficiencies of heaters shall not fall below the following values:
Fuel boiler space heaters with rated heat output ≤ 70 kW and fuel boiler combination heaters with rated heat output ≤ 70 kW, with the exception of type B1 boilers with rated heat output ≤ 10 kW and type B1 combination boilers with rated heat output ≤ 30 kW:
The seasonal space heating energy efficiency shall not fall below 86 %.
Type B1 boilers with rated heat output ≤ 10 kW and type B1 combination boilers with rated heat output ≤ 30 kW:
The seasonal space heating energy efficiency shall not fall below 75 %.
Fuel boiler space heaters with rated heat output > 70 kW and ≤ 400 kW and fuel boiler combination heaters with rated heat output > 70 kW and ≤ 400 kW:
The useful efficiency at 100 % of the rated heat output shall not fall below 86 %, and the useful efficiency at 30 % of the rated heat output shall not fall below 94 %.
Electric boiler space heaters and electric boiler combination heaters:
The seasonal space heating energy efficiency shall not fall below 30 %.
Cogeneration space heaters:
The seasonal space heating energy efficiency shall not fall below 86 %.
Heat pump space heaters and heat pump combination heaters, with the exception of low-temperature heat pumps:
The seasonal space heating energy efficiency shall not fall below 100 %.
Low-temperature heat pumps:
The seasonal space heating energy efficiency shall not fall below 115 %.
From 26 September 2017 the seasonal space heating energy efficiency of electric boiler space heaters, electric boiler combination heaters, cogeneration space heaters, heat pump space heaters and heat pump combination heaters shall not fall below the following values:
Electric boiler space heaters and electric boiler combination heaters:
The seasonal space heating energy efficiency shall not fall below 36 %.
Cogeneration space heaters:
The seasonal space heating energy efficiency shall not fall below 100 %.
Heat pump space heaters and heat pump combination heaters, with the exception of low-temperature heat pumps:
The seasonal space heating energy efficiency shall not fall below 110 %.
Low-temperature heat pumps:
The seasonal space heating energy efficiency shall not fall below 125 %.
Declared load profile | 3XS | XXS | XS | S | M | L | XL | XXL | 3XL | 4XL |
---|---|---|---|---|---|---|---|---|---|---|
Water heating energy efficiency | 22 % | 23 % | 26 % | 26 % | 30 % | 30 % | 30 % | 32 % | 32 % | 32 % |
Declared load profile | 3XS | XXS | XS | S | M | L | XL | XXL | 3XL | 4XL |
---|---|---|---|---|---|---|---|---|---|---|
Water heating energy efficiency | 32 % | 32 % | 32 % | 32 % | 36 % | 37 % | 38 % | 60 % | 64 % | 64 % |
From 26 September 2015 the sound power level of heat pump space heaters and heat pump combination heaters shall not exceed the following values:
Rated heat output ≤ 6 kW | Rated heat output > 6 kW and ≤ 12 kW | Rated heat output > 12 kW and ≤ 30 kW | Rated heat output > 30 kW and ≤ 70 kW | ||||
---|---|---|---|---|---|---|---|
Sound power level (LWA ), indoors | Sound power level (LWA ), outdoors | Sound power level (LWA ), indoors | Sound power level (LWA ), outdoors | Sound power level (LWA ), indoors | Sound power level (LWA ), outdoors | Sound power level (LWA ), indoors | Sound power level (LWA ), outdoors |
60 dB | 65 dB | 65 dB | 70 dB | 70 dB | 78 dB | 80 dB | 88 dB |
fuel boiler space heaters and fuel boiler combination heaters using gaseous fuels: 56 mg/kWh fuel input in terms of GCV;
fuel boiler space heaters and fuel boiler combination heaters using liquid fuels: 120 mg/kWh fuel input in terms of GCV;
cogeneration space heaters equipped with external combustion using gaseous fuels: 70 mg/kWh fuel input in terms of GCV;
cogeneration space heaters equipped with external combustion using liquid fuels: 120 mg/kWh fuel input in terms of GCV;
cogeneration space heaters equipped with an internal combustion engine using gaseous fuels: 240 mg/kWh fuel input in terms of GCV;
cogeneration space heaters equipped with an internal combustion engine using liquid fuels: 420 mg/kWh fuel input in terms of GCV;
heat pump space heaters and heat pump combination heaters equipped with external combustion using gaseous fuels: 70 mg/kWh fuel input in terms of GCV;
heat pump space heaters and heat pump combination heaters equipped with external combustion using liquid fuels: 120 mg/kWh fuel input in terms of GCV;
heat pump space heaters and heat pump combination heaters equipped with an internal combustion engine using gaseous fuels: 240 mg/kWh fuel input in terms of GCV;
heat pump space heaters and heat pump combination heaters equipped with an internal combustion engine using liquid fuels: 420 mg/kWh fuel input in terms of GCV.
From 26 September 2015 the following product information on heaters shall be provided:
the instruction manuals for installers and end-users, and free access websites of manufacturers, their authorised representatives and importers shall contain the following elements:
for boiler space heaters, boiler combination heaters and cogeneration space heaters, the technical parameters set out in Table 1, measured and calculated in accordance with Annex III;
for heat pump space heaters and heat pump combination heaters, the technical parameters set out in Table 2, measured and calculated in accordance with Annex III;
any specific precautions that shall be taken when the heater is assembled, installed or maintained;
for type B1 boilers and type B1 combination boilers, their characteristics and the following standard text: ‘This natural draught boiler is intended to be connected only to a flue shared between multiple dwellings in existing buildings that evacuates the residues of combustion to the outside of the room containing the boiler. It draws the combustion air directly from the room and incorporates a draught diverter. Due to lower efficiency, any other use of this boiler shall be avoided and would result in higher energy consumption and higher operating costs.’;
for heat generators designed for heaters, and heater housings to be equipped with such heat generators, their characteristics, the requirements for assembly, to ensure compliance with the ecodesign requirements for heaters and, where appropriate, the list of combinations recommended by the manufacturer;
information relevant for disassembly, recycling and/or disposal at end-of-life;
the technical documentation for the purposes of conformity assessment pursuant to Article 4 shall contain the following elements:
the elements specified in point (a);
for heat pump space heaters and heat pump combination heaters where the information relating to a specific model comprising a combination of indoor and outdoor units has been obtained by calculation on the basis of design and/or extrapolation from other combinations, the details of such calculations and/or extrapolations, and of any tests undertaken to verify the accuracy of the calculations, including details of the mathematical model for calculating the performance of such combinations and details of the measurements taken to verify this model;
the following information shall be durably marked on the heater:
if applicable, ‘type B1 boiler’ or ‘type B1 combination boiler’;
for cogeneration space heaters, the electrical capacity.
Information requirements for boiler space heaters, boiler combination heaters and cogeneration space heaters
a High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet. | ||||||||
b Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return temperature (at heater inlet). | ||||||||
Model(s): [information identifying the model(s) to which the information relates] | ||||||||
Condensing boiler: [yes/no] | ||||||||
Low-temperatureb boiler: [yes/no] | ||||||||
B1 boiler: [yes/no] | ||||||||
Cogeneration space heater: [yes/no] | If yes, equipped with a supplementary heater: [yes/no] | |||||||
Combination heater: [yes/no] | ||||||||
Item | Symbol | Value | Unit | Item | Symbol | Value | Unit | |
---|---|---|---|---|---|---|---|---|
Rated heat output | Prated | x | kW | Seasonal space heating energy efficiency | ηs | x | % | |
For boiler space heaters and boiler combination heaters: Useful heat output | For boiler space heaters and boiler combination heaters: Useful efficiency | |||||||
At rated heat output and high-temperature regimea | P4 | x,x | kW | At rated heat output and high-temperature regimea | η4 | x,x | % | |
At 30 % of rated heat output and low-temperature regimeb | P1 | x,x | kW | At 30 % of rated heat output and low-temperature regimeb | η1 | x,x | % | |
For cogeneration space heaters: Useful heat output | For cogeneration space heaters: Useful efficiency | |||||||
At rated heat output of cogeneration space heater with supplementary heater disabled | PCHP100 + Sup0 | x,x | kW | At rated heat output of cogeneration space heater with supplementary heater disabled | ηCHP100 + Sup0 | x,x | % | |
At rated heat output of cogeneration space heater with supplementary heater enabled | PCHP100 + Sup100 | x,x | kW | At rated heat output of cogeneration space heater with supplementary heater enabled | ηCHP100 + Sup100 | x,x | % | |
For cogeneration space heaters: Electrical efficiency | Supplementary heater | |||||||
At rated heat output of cogeneration space heater with supplementary heater disabled | ηel,CHP100 + Sup0 | x,x | % | Rated heat output | Psup | x,x | kW | |
At rated heat output of cogeneration space heater with supplementary heater enabled | ηel,CHP100 + Sup100 | x,x | % | Type of energy input | ||||
Auxiliary electricity consumption | Other items | |||||||
At full load | elmax | x,xxx | kW | Standby heat loss | Pstby | x,xxx | kW | |
At part load | elmin | x,xxx | kW | Ignition burner power consumption | Pign | x,xxx | kW | |
In standby mode | PSB | x,xxx | kW | Emissions of nitrogen oxides | NOx | x | mg/kWh | |
For combination heaters: | ||||||||
Declared load profile | Water heating energy efficiency | ηwh | x | % | ||||
Daily electricity consumption | Qelec | x,xxx | kWh | Daily fuel consumption | Qfuel | x,xxx | kWh | |
Contact details | Name and address of the manufacturer or its authorised representative. |
Information requirements for heat pump space heaters and heat pump combination heaters
a For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj). | ||||||||
b If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9. | ||||||||
Model(s): [information identifying the model(s) to which the information relates] | ||||||||
Air-to-water heat pump: [yes/no] | ||||||||
Water-to-water heat pump: [yes/no] | ||||||||
Brine-to-water heat pump: [yes/no] | ||||||||
Low-temperature heat pump: [yes/no] | ||||||||
Equipped with a supplementary heater: [yes/no] | ||||||||
Heat pump combination heater: [yes/no] | ||||||||
Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps. For low-temperature heat pumps, parameters shall be declared for low-temperature application. | ||||||||
Parameters shall be declared for average climate conditions. | ||||||||
Item | Symbol | Value | Unit | Item | Symbol | Value | Unit | |
---|---|---|---|---|---|---|---|---|
Rated heat output a | Prated | x | kW | Seasonal space heating energy efficiency | ηs | x | % | |
Declared capacity for heating for part load at indoor temperature 20 °C and outdoor temperature Tj | Declared coefficient of performance or primary energy ratio for part load at indoor temperature 20 °C and outdoor temperature Tj | |||||||
Tj = – 7 °C | Pdh | x,x | kW | Tj = – 7 °C | COPd or PERd | x,xx or x,x | – or % | |
Tj = + 2 °C | Pdh | x,x | kW | Tj = + 2 °C | COPd or PERd | x,xx or x,x | – or % | |
Tj = + 7 °C | Pdh | x,x | kW | Tj = + 7 °C | COPd or PERd | x,xx or x,x | – or % | |
Tj = + 12 °C | Pdh | x,x | kW | Tj = + 12 °C | COPd or PERd | x,xx or x,x | – or % | |
Tj = bivalent temperature | Pdh | x,x | kW | Tj = bivalent temperature | COPd or PERd | x,xx or x,x | – or % | |
Tj = operation limit temperature | Pdh | x,x | kW | Tj = operation limit temperature | COPd or PERd | x,xx or x,x | – or % | |
For air-to-water heat pumps: Tj = – 15 °C (if TOL < – 20 °C) | Pdh | x,x | kW | For air-to-water heat pumps: Tj = – 15 °C (if TOL < – 20 °C) | COPd or PERd | x,xx or x,x | – or % | |
Bivalent temperature | Tbiv | x | °C | For air-to-water heat pumps: Operation limit temperature | TOL | x | °C | |
Cycling interval capacity for heating | Pcych | x,x | kW | Cycling interval efficiency | COPcyc or PERcyc | x,xx or x,x | – or % | |
Degradation co-efficientb | Cdh | x,x | — | Heating water operating limit temperature | WTOL | x | °C | |
Power consumption in modes other than active mode | Supplementary heater | |||||||
Off mode | POFF | x,xxx | kW | Rated heat outputa | Psup | x,x | kW | |
Thermostat-off mode | PTO | x,xxx | kW | |||||
Standby mode | PSB | x,xxx | kW | Type of energy input | ||||
Crankcase heater mode | PCK | x,xxx | kW | |||||
Other items | ||||||||
Capacity control | fixed/variable | For air-to-water heat pumps: Rated air flow rate, outdoors | — | x | m3/h | |||
Sound power level, indoors/outdoors | LWA | x/x | dB | For water-/brine-to-water heat pumps: Rated brine or water flow rate, outdoor heat exchanger | — | x | m3/h | |
Emissions of nitrogen oxides | NOx | x | mg/kWh | |||||
For heat pump combination heater: | ||||||||
Declared load profile | x | Water heating energy efficiency | ηwh | x | % | |||
Daily electricity consumption | Qelec | x,xxx | kWh | Daily fuel consumption | Qfuel | x,xxx | kWh | |
Contact details | Name and address of the manufacturer or its authorised representative. |
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As adopted by EU): The original version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: