Search Legislation

The Eggborough Gas Fired Generating Station Order 2018

Status:

This is the original version (as it was originally made).

Requirement 5

SCHEDULE 14DESIGN PARAMETERS

PART 1SINGLE SHAFT PARAMETERS

1.  The maximum parameters for the buildings and structures for the single shaft layout are set out at table 14.

2.  The maximum parameters and grid reference location of the combined cycle gas turbine stacks are set out in table 15.

3.  The finished ground level in respect of Work No. 1 is between 7.9 metres AOD and 9.9 metres AOD.

Table 14

(1)

Component

(2)

Maximum length (m)

(3)

Maximum width (m)

(4)

Maximum height (m)

(5)

Maximum diameter (m)

Gas turbine hall building767630-
Heat recovery steam generator632850-
Electrical building near heat recovery steam generator302710-
Combine cycle gas turbine air intake filters (each)241630-
Electrical building near air intake filter391610-
Generator transformer302415-
Feed water pump building642320-
Demineralised water treatment plant, fire pumps and laboratory573320-
Demineralised water storage tank--2025
Gas reception facility65525-
Gas compressors502010-
Auxiliary boiler301520-
Auxiliary boiler stacks (each)--251.5
Combined cycle gas turbine standby diesel generators1998-
Continuous emissions monitoring system container1033-
Cooling towers (each)2402725-
Cooling water electrical module15610-
Cooling water pumps30158-
Cooling water sampling and dosing plant19118-
Peaking plant building1036530-
Peaking plant stack(s) (each) (open cycle gas turbine)--458
Peaking plant stack(s) (each) (gas engine)--281.3
Black start facility554330-
Black start facility stack(s) (each) (open cycle gas turbine)--452.5
Black start facility stack(s) (each) (gas engine)--251.3
Diesel tank for black start diesel generator--124
Electrical control room and administration building852420-
Electrical substation401715-
Workshop and stores512012-
Raw and fire water tank--2025
Gas bottle stores (each)1753-
Closed-circuit cooling water coolers151010-
Waste water treatment plant552820-
Firewater and stormwater retention basins110500-
Gatehouse12125-

Table 15

(1)

Component

(2)

Grid reference of centre point of each stack (using reference system OSGB36 - Ordnance Survey Great Britain 1936)

(3)

Maximum diameter of each stack (m)

(4)

Top of each stack in mAOD

Combined cycle gas turbine stack

First stack—

457600

423933

Second Stack—

457593

423944

Third Stack—

457587

423933

9.699.9

PART 2MULTI-SHAFT PARAMETERS

4.  The maximum parameters for the buildings and structures for the multi shaft layout are set out at table 16.

5.  The maximum parameters and grid reference location of the combined cycle gas turbine stacks are set out in table 17.

6.  The finished ground level in respect of Work No. 1 is between 7.9 metres AOD and 9.9 metres AOD.

Table 16

(1)

Component

(2)

Maximum length (m)

(3)

Maximum width (m)

(4)

Maximum height (m)

(5)

Maximum diameter (m)

Gas turbine hall building767630-
Steam turbine hall building645430-
Heat recovery steam generator632850-
Electrical building near heat recovery steam generator302710-
Combine cycle gas turbine air intake filters (each)241630-
Electrical building near air intake filter241610-
Generator transformer212015-
Feed water pump building542620-
Demineralised water treatment plant, fire pumps and laboratory573320-
Demineralised water storage tank--2025
Gas reception facility65525-
Gas compressors502010-
Auxiliary boiler301520-
Auxiliary boiler stacks (each)--251.5
Combined cycle gas turbine standby diesel generators1998-
Continuous emissions monitoring system container1033-
Cooling towers (each)2402730-
Cooling water electrical module15610-
Cooling water pumps30158-
Cooling water sampling and dosing plant19118-
Peaking plant building1036530-
Peaking plant stack(s) (each) (open cycle gas turbine)--458
Peaking plant stack(s) (each) (gas engine)--281.3
Black start facility554330-
Black start facility stack(s) (each) (open cycle gas turbine)--452.5
Black start facility stack(s) (each) (gas engine)--251.3
Diesel tank for black start diesel generator--124
Electrical control room and administration building852420-
Electrical substation351515-
Workshop and stores512012-
Raw and fire water tank--2025
Gas bottle stores (each)1753-
Closed-circuit cooling water coolers151010-
Waste water treatment plant552820-
Firewater and stormwater retention basins110500-
Gatehouse12125-

Table 17

(1)

Component

(2)

Grid reference of centre point of each stack (using reference system OSGB36 - Ordnance Survey Great Britain 1936)

(3)

Maximum diameter of each stack (m)

(4)

Top of each stack in mAOD

Combined cycle gas turbine stack

First stack—

457600

423933

Second Stack—

457593

423944

Third Stack—

457587

423933

9.699.9

Back to top

Options/Help

Print Options

Close

Legislation is available in different versions:

Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.

Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.

Close

Opening Options

Different options to open legislation in order to view more content on screen at once

Close

More Resources

Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as enacted version that was used for the print copy
  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • correction slips
  • links to related legislation and further information resources
Close

More Resources

Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as made version that was used for the print copy
  • correction slips

Click 'View More' or select 'More Resources' tab for additional information including:

  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • links to related legislation and further information resources