Frequency range | External electric field strength Low ALs (E) [Vm-1] | External electric field strength High ALs (E) [Vm-1] |
---|---|---|
1 ≤ f < 25 Hz | 2.0 × 104 | 2.0 × 104 |
25 ≤ f < 50 Hz | 5.0 × 105/f | 2.0 × 104 |
50 Hz ≤ f < 1.64 kHz | 5.0 × 105/f | 1.0 × 106/f |
1.64 ≤ f < 3 kHz | 5.0 × 105/f | 6.1 × 102 |
3 kHz ≤ f ≤ 10 MHz | 1.7 × 102 | 6.1 × 102 |
Exposure levels not exceeding the ALs will be compliant with: | Tables ELV2 and ELV3 |
1. Between the Low and High ALs, exposure will be below the ELVs but spark discharges may occur. These can be prevented through the provision of information and training under regulation 10 and the use of suitable technical and personal protection measures.
2. The ALs in Tables AL1 and AL2 are root mean square (RMS) values of the field strength. These RMS values are equal to the peak values divided by √2 for sinusoidal fields. The corresponding ELVs in Tables ELV2 and ELV3 are peak values in time, which are equal to the RMS values multiplied by √2 for sinusoidal fields. In the case of non-sinusoidal fields the exposure assessment under regulation 5 must be based on the weighted peak method (filtering in time domain) or on a scientifically proven and validated exposure evaluation procedure which produces comparable results to the weighted peak method.
3. The ALs represent the maximum field values at any place where an employee may be working, before the entry of any person into the field. In the case of an electromagnetic field source in the immediate vicinity of the body, compliance with the ELVs must be determined dosimetrically, case by case.
Frequency range | Magnetic flux density Low ALs (B)[µT] | Magnetic flux density High ALs (B)[µT] | Magnetic flux density ALs for exposure of limbs to a localised magnetic field (B) [µT] |
---|---|---|---|
1 ≤ f < 8 Hz | 2.0 × 105/f2 | 3.0 × 105/f | 9.0 × 105/f |
8 ≤ f < 25 Hz | 2.5 × 104/f | 3.0 × 105/f | 9.0 × 105/f |
25 ≤ f < 300 Hz | 1.0 × 103 | 3.0 × 105/f | 9.0 × 105/f |
300 Hz ≤ f < 3 kHz | 3.0 × 105/f | 3.0 × 105/f | 9.0 × 105/f |
3 kHz ≤ f ≤ 10 MHz | 1.0 × 102 | 1.0 × 102 | 3.0 × 102 |
Exposure levels not exceeding the ALs will be compliant with: | At and below 400 Hz: the sensory effect ELVs in Table ELV3 | The health effect ELVs in Table ELV2 | |
Above 400 Hz: the health effect ELVs in Table ELV2 |
1. Between the Low and High ALs for exposure up to 400 Hz, exposure in the head of the employee will be below the health effect ELVs but may exceed the sensory effect ELVs in Table ELV3.
2. Notes 2 and 3 to Table AL1 apply.
Frequency range | External electric field strength ALs (E) [Vm-1] | Magnetic flux density ALs (B)[µT] | Power density AL (S)[Wm-2] |
---|---|---|---|
100 kHz ≤ f < 1 MHz | 6.1 × 102 | 2.0 × 106/f | - |
1 ≤ f < 10 MHz | 6.1 × 108/f | 2.0 × 106/f | - |
10 ≤ f < 400 MHz | 61 | 0.2 | - |
400 MHz ≤ f < 2 GHz | 3 × 10-3 f1/2 | 1.0 × 10-5 f1/2 | - |
2 ≤ f < 6 GHz | 1.4 × 102 | 4.5 × 10-1 | - |
6 ≤ f ≤ 300 GHz | 1.4 × 102 | 4.5 × 10-1 | 50 |
Exposure levels not exceeding the ALs will be compliant with: | Up to 6 GHz: the health effect ELVs in Table ELV4 6 - 300 GHz: the health effect ELV in Table ELV6 | The health effect ELV in Table ELV6 |
1. The electric field strength and magnetic flux density ALs are root mean square values.
2. For radiofrequency pulses, the peak power density averaged over the pulse width must not exceed 1000 times the respective AL (S) value. For multi-frequency fields, the analysis must be based on summation.
3. Note 3 to Table AL1 applies in relation to the ALs for external electric field strength and magnetic flux density.
4. The power density is the maximum level averaged over any 20cm2 of exposed area. Spatial maximum power densities averaged over 1cm2 must not exceed 20 times the value of 50 Wm-2.
5. From 6 to 10 GHz, power density must be averaged over a six minute period. Above 10 GHz, it must be averaged over a 68/f1.05-minute period (where “f” is the frequency in GHz).
Frequency range | Limb current AL (IL) [mA] |
---|---|
10 ≤ f ≤ 110 MHz | 100 |
Exposure levels not exceeding the ALs will be compliant with: | The health effect ELV in Table ELV4 - localised SAR in the limbs |
The AL is a root mean square value.
Sensory effect ELVs – magnetic flux density (B0) [T] | |
---|---|
Head and trunk | 2 |
Limbs | 8 |
Health effect ELV – magnetic flux density (B0) [T] | |
Any part of the body | 8 |
The sensory effect ELVs may be exceeded during an employee’s shift where the employer ensures that—
(a)they are only exceeded temporarily;
(b)protection measures have been adopted which minimise, so far as is reasonably practicable, the sensory effects related to movement in static magnetic fields, including nausea and vertigo;
(c)adequate information is provided to the employee on the possibility of those sensory effects; and
(d)where any of those sensory effects are reported to the employer, the exposure assessment under regulation 5, and the protection measures, are updated where necessary.
Frequency range | Health effect ELVs – internal electric field strength (E) [Vm-1] |
---|---|
1 Hz ≤ f < 3 kHz | 1.1 |
3 kHz ≤ f ≤ 10 MHz | 3.8 × 10-4 f |
1. The ELVs are limits for electric fields induced in the body from exposure to time-varying electric and magnetic fields.
2. The ELVs are spatial peak values in the entire body of the employee.
3. Note 2 to Table AL1 applies in relation to methods of determining exposure.
Frequency range | Sensory effect ELVs – internal electric field strength in the head (E) [Vm-1] |
---|---|
1 ≤ f < 10 Hz | 0.7/f |
10 ≤ f < 25 Hz | 0.07 |
25 ≤ f ≤ 400 Hz | 0.0028 f |
1. The ELVs are spatial peak values induced in the head of the exposed employee, and can arise from exposure to either external electric or external magnetic fields.
2. The ELVs may be exceeded during an employee’s shift where the employer ensures that—
(a)they are only exceeded temporarily;
(b)hazardous spark discharges, and contact currents in excess of those in Table AL5, are prevented through the provision of information and training under regulation 10 and the use of suitable technical and personal protection measures;
(c)adequate information is provided to the employee on the possibility of sensory effects related to time-varying magnetic fields, including retinal phosphenes; and
(d)where any of those sensory effects are reported to the employer, the risk assessment is updated where necessary.
3. Note 2 to Table AL1 applies in relation to methods of determining exposure.
Area of exposure | Health effect ELVs – specific energy absorption rate (SAR) [Wkg-1] |
---|---|
Whole body | 0.4 (averaged SAR in the body) |
Head and trunk | 10 (localised SAR in the head and trunk) |
Limbs | 20 (localised SAR in the limbs) |
1. The ELVs correspond to the SAR values averaged over a six minute period.
2. Localised SAR in the body and limbs can be assessed by either computational dosimetry or physical measurement of 10 grams of tissue. For computational dosimetry, 10 grams of contiguous tissue with approximately homogeneous electrical properties must be used for the SAR average. For direct physical measurements a simple geometry, such as cubic or spherical tissue mass, may be used. The maximum value obtained must be assessed against the ELVs.
Frequency range | Sensory effect ELV – specific energy absorption in the head (SA) [mJkg-1] |
---|---|
300 MHz ≤ f ≤ 6GHz | 10 |
1. When determining SA, energy absorption must be averaged over 10 grams of tissue.
2. The ELV may be exceeded during an employee’s shift where the employer ensures that—
(a)it is only exceeded temporarily;
(b)adequate information is provided to the employee on the possibility of sensory effects related to pulsed microwave radiation, including auditory sensations; and
(c)where any of those sensory effects are reported to the employer, the risk assessment is updated where necessary.
Frequency range | Health effect ELV – power density (S) [Wm-2] |
---|---|
6 GHz ≤ f ≤ 300GHz | 50 |
1. The power density is the maximum level averaged over any 20cm2 of exposed area. Spatial maximum power densities averaged over 1cm2 must not exceed 20 times the value of 50 Wm-2.
2. From 6 to 10 GHz, power density must be averaged over a six minute period. Above 10 GHz, it must be averaged over a 68/f1.05-minute period (where “f” is the frequency in GHz).
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.
Explanatory Memorandum sets out a brief statement of the purpose of a Statutory Instrument and provides information about its policy objective and policy implications. They aim to make the Statutory Instrument accessible to readers who are not legally qualified and accompany any Statutory Instrument or Draft Statutory Instrument laid before Parliament from June 2004 onwards.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
Impact Assessments generally accompany all UK Government interventions of a regulatory nature that affect the private sector, civil society organisations and public services. They apply regardless of whether the regulation originates from a domestic or international source and can accompany primary (Acts etc) and secondary legislation (SIs). An Impact Assessment allows those with an interest in the policy area to understand:
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: