45.—(1) In every ship the number of skylights, doors, ventilators, openings in funnels for exhaust ventilation and other openings, to machinery spaces shall be the minimum compatible with the proper working and safety of the ship.
(2) The skylights to machinery spaces of Category A shall be constructed of steel and their flaps shall be capable of being closed and opened from a suitable position outside the space in the event of fire. Adequate arrangements shall be made to permit the release of smoke in the event of fire.
(3) Windows shall not be fitted in machinery space boundaries. This requirement shall not preclude the use of glass in control rooms located within the machinery space boundaries.
(4) Any machinery space of Category A which is accessible from an adjacent shaft tunnel shall be provided with a light-weight steel fire-screen door in addition to any water tight door. The fire-screen door shall be operable from each side and shall be located at the shaft tunnel side of the bulkhead.
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include: