3.—(1) Reagents of analytical quality shall be used.
(2) The buffer-substrate solution shall be prepared as follows:—
(a)buffer solution: 3.5 g. of anhydrous sodium carbonate and 1.5 g.of sodium bicarbonate shall be dissolved in distilled water, and made up to one litre;
(b)substrate: Disodium p-nitrophenyl phosphate. The solid substrate shall be kept in a refrigerator;
(c)buffer-substrate solution: 0.15 g. of the substrate shall be placed in a 100 ml. measuring cylinder or graduated flask, and made up to 100 ml. with the buffer solution. The solution shall be stored in a refrigerator and protected from light. It shall give a reading of less than the standard marked 10 on the comparator disc A.P.T.W. or A.P.T.W.7 when viewed in transmitted light through a 25 mm. cell in the “all purposes” comparator, distilled water being used for comparison. The solution shall not be used for more than one week.
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: