7.—(1) The provisions of this regulation shall apply when a device is used to measure the underlying level of noise.
(2) If the measurement is made within a room in the relevant place, the windows and doors in that room shall be closed.
(3) The measuring microphone of the approved device shall be positioned at least 0.5 metres away from any surface in the room (including the floor) and from any items of furniture.
(4) The A-weighted sound pressure level shall be measured using time-weighting ‘F’.
(5) Where a measurement obtained under paragraph (4) is not a whole number, it shall be rounded up to the nearest whole number.
(6) The measurement under paragraph (4) shall be made at the same time as the measurement under regulation 6(4).
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: