Commission Regulation (EU) No 814/2013 of 2 August 2013 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for water heaters and hot water storage tanks (Text with EEA relevance)
When the UK left the EU, legislation.gov.uk published EU legislation that had been published by the EU up to IP completion day (31 December 2020 11.00 p.m.). On legislation.gov.uk, these items of legislation are kept up-to-date with any amendments made by the UK since then.
Legislation.gov.uk publishes the UK version. EUR-Lex publishes the EU version. The EU Exit Web Archive holds a snapshot of EUR-Lex’s version from IP completion day (31 December 2020 11.00 p.m.).
This is the original version as it was originally adopted in the EU.
This legislation may since have been updated - see the latest available (revised) version
Declared load profile | 3XS | XXS | XS | S | M | L | XL | XXL | 3XL | 4XL |
---|---|---|---|---|---|---|---|---|---|---|
Water heating energy efficiency | 22 % | 23 % | 26 % | 26 % | 30 % | 30 % | 30 % | 32 % | 32 % | 32 % |
In addition, for water heaters with smart being declared as ‘1’: water heating energy efficiency calculated for smart = 0, tested under the declared load profile | 19 % | 20 % | 23 % | 23 % | 27 % | 27 % | 27 % | 28 % | 28 % | 28 % |
Declared load profile | 3XS | XXS | XS | S | M | L | XL | XXL | 3XL | 4XL |
---|---|---|---|---|---|---|---|---|---|---|
Water heating energy efficiency | 32 % | 32 % | 32 % | 32 % | 36 % | 37 % | 37 % | 37 % | 37 % | 38 % |
In addition, for water heaters with smart being declared as ‘1’: water heating energy efficiency calculated for smart = 0, tested under the declared load profile | 29 % | 29 % | 29 % | 29 % | 33 % | 34 % | 35 % | 36 % | 36 % | 36 % |
Declared load profile | XXL | 3XL | 4XL |
---|---|---|---|
Water heating energy efficiency | 60 % | 64 % | 64 % |
From 26 September 2015:
for storage water heaters with declared load profile 3XS the storage volume shall not exceed 7 litres;
for storage water heaters with declared load profiles XXS and XS, the storage volume shall not exceed 15 litres;
for storage water heaters with declared load profile S the storage volume shall not exceed 36 litres.
From 26 September 2015 the amount of mixed water at 40 °C shall not fall below the following values:
Declared load profile | M | L | XL | XXL | 3XL | 4XL |
---|---|---|---|---|---|---|
Mixed water at 40 °C | 65 litres | 130 litres | 210 litres | 300 litres | 520 litres | 1 040 litres |
From 26 September 2015 the sound power level of heat pump water heaters shall not exceed the following values:
Rated heat output ≤ 6 kW | Rated heat output > 6 kW and ≤ 12 kW | Rated heat output > 12 kW and ≤ 30 kW | Rated heat output > 30 kW and ≤ 70 kW | ||||
---|---|---|---|---|---|---|---|
Sound power level (LWA ), indoors | Sound power level (LWA ), outdoors | Sound power level (LWA ), indoors | Sound power level (LWA ), outdoors | Sound power level (LWA ), indoors | Sound power level (LWA ), outdoors | Sound power level (LWA ), indoors | Sound power level (LWA ), outdoors |
60 dB | 65 dB | 65 dB | 70 dB | 70 dB | 78 dB | 80 dB | 88 dB |
conventional water heaters using gaseous fuels: 56 mg/kWh fuel input in terms of GCV,
conventional water heaters using liquid fuels: 120 mg/kWh fuel input in terms of GCV,
heat pump water heaters equipped with external combustion using gaseous fuels and solar water heaters using gaseous fuels: 70 mg/kWh fuel input in terms of GCV,
heat pump water heaters equipped with external combustion using liquid fuels and solar water heaters using liquid fuels: 120 mg/kWh fuel input in terms of GCV,
heat pump water heaters equipped with an internal combustion engine using gaseous fuels: 240 mg/kWh fuel input in terms of GCV,
heat pump water heaters equipped with an internal combustion engine using liquid fuels: 420 mg/kWh fuel input in terms of GCV.
From 26 September 2015 the instruction manuals for installers and end-users, free access websites of manufacturers, their authorised representatives and importers and technical documentation for the purposes of conformity assessment pursuant to Article 4 shall contain the following elements:
information identifying the model(s), including equivalent models, to which the information relates;
the results of the measurements for the technical parameters specified in point 6 of Annex III;
the results of the calculations for the technical parameters specified in point 2 of Annex IV;
any specific precautions that shall be taken when the water heater is assembled, installed or maintained;
for heat generators designed for water heaters and water heater housings to be equipped with such heat generators, their characteristics, the requirements for assembly, to ensure compliance with the ecodesign requirements for water heaters and, where appropriate, the list of combinations recommended by the manufacturer;
information relevant for disassembly, recycling and/or disposal at end-of-life.
From 26 September 2017 the standing loss S of hot water storage tanks with storage volume V, expressed in litres, shall not exceed the following limit:
From 26 September 2015 the instruction manuals for installers and end-users, the free access websites of manufacturers, their authorised representatives and importers and technical documentation for the purposes of conformity assessment pursuant to Article 4 shall contain the following elements:
information identifying the model(s), including equivalent models, to which the information relates;
the results of the measurements for the technical parameters specified in point 7 of Annex III;
any specific precautions that shall be taken when the hot water storage tank is assembled, installed or maintained;
information relevant for disassembly, recycling and/or disposal at end-of-life.
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As adopted by EU): The original version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: