The following parameters shall be established for water heaters:
the daily electricity consumption Qelec in kWh, rounded to three decimal places;
the declared load profile, expressed by the appropriate letter in accordance with Table 3 of this Annex;
the sound power level in dB, indoors, rounded to the nearest integer (for heat pump water heaters, if applicable);
in addition, for water heaters using fossil and/or biomass fuels:
the daily fuel consumption Qfuel in kWh in terms of GCV, rounded to three decimal places;
in addition, for water heaters for which the value of smart is declared as being ‘1’:
the weekly fuel consumption with smart controls Qfuel,week,smart in kWh in terms of GCV, rounded to three decimal places;
the weekly electricity consumption with smart controls Qelec,week,smart in kWh, rounded to three decimal places;
the weekly fuel consumption without smart controls Qfuel,week in kWh in terms of GCV, rounded to three decimal places;
the weekly electricity consumption without smart controls Qelec,week in kWh, rounded to three decimal places;
in addition, for solar water heaters:
the collector aperture area Asol in m2, rounded to two decimal places;
the zero-loss efficiency η0 , rounded to three decimal places;
the first-order coefficient a1 in W/(m2 K), rounded to two decimal places;
the second-order coefficient a2 in W/(m2 K2), rounded to three decimal places;
the incidence angle modifier IAM, rounded to two decimal places;
the pump power consumption solpump in W, rounded to two decimal places;
the standby power consumption solstandby in W, rounded to two decimal places;
in addition, for heat pump water heaters:
the sound power level LWA in dB, outdoors, rounded to the nearest integer.
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As adopted by EU): The original version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: