Commission Delegated Regulation (EU) No 811/2013 of 18 February 2013 supplementing Directive 2010/30/EU of the European Parliament and of the Council with regard to the energy labelling of space heaters, combination heaters, packages of space heater, temperature control and solar device and packages of combination heater, temperature control and solar device (Text with EEA relevance)
When the UK left the EU, legislation.gov.uk published EU legislation that had been published by the EU up to IP completion day (31 December 2020 11.00 p.m.). On legislation.gov.uk, these items of legislation are kept up-to-date with any amendments made by the UK since then.
Legislation.gov.uk publishes the UK version. EUR-Lex publishes the EU version. The EU Exit Web Archive holds a snapshot of EUR-Lex’s version from IP completion day (31 December 2020 11.00 p.m.).
This is the original version as it was originally adopted in the EU.
This legislation may since have been updated - see the latest available (revised) version
The solar collector, solar hot water storage tank and pump in the collector loop (if applicable) shall be tested separately. Where the solar collector and solar hot water storage tank cannot be tested separately, they shall be tested in combination.
The results shall be used for the determination of the standing loss S and the calculations of the collector efficiency ηcol , the annual non-solar heat contribution Qnonsol for the load profiles M, L, XL and XXL under the average climate conditions set out in Tables 13 and 14, and the annual auxiliary electricity consumption Qaux in kWh in terms of final energy.
Standard rating conditions for heat pump space heaters and heat pump combination heaters
Heat source | Outdoor heat exchanger | Indoor heat exchanger | ||||
---|---|---|---|---|---|---|
Climate condition | Inlet dry bulb (wet bulb) temperature | Heat pump space heaters and heat pump combination heaters, except low-temperature heat pumps | Low-temperature heat pumps | |||
Inlet temperature | Outlet temperature | Inlet temperature | Outlet temperature | |||
Outdoor air | Average | + 7 °C (+ 6 °C) | 47 °C | 55 °C | 30 °C | 35 °C |
Colder | + 2 °C (+ 1 °C) | |||||
Warmer | + 14 °C (+ 13 °C) | |||||
Exhaust air | All | + 20 °C (+ 12 °C) | ||||
Inlet / outlet temperature | ||||||
Water | All | + 10 °C / + 7 °C | ||||
Brine | All | 0 °C/– 3 °C |
Reference design conditions for heat pump space heaters and heat pump combination heaters, temperatures in dry bulb air temperature (wet bulb air temperature indicated in brackets)
Climate condition | Reference design temperature | Bivalent temperature | Operation limit temperature |
---|---|---|---|
Tdesignh | Tbiv | TOL | |
Average | – 10 (– 11) °C | maximum + 2 °C | maximum – 7 °C |
Colder | – 22 (– 23) °C | maximum – 7 °C | maximum – 15 °C |
Warmer | + 2 (+ 1) °C | maximum + 7 °C | maximum + 2 °C |
Maximum ventilation exhaust air available [m3/h], with humidity of 5,5 g/m3
Declared load profile | XXS | XS | S | M | L | XL | XXL |
---|---|---|---|---|---|---|---|
Maximum ventilation exhaust air available | 109 | 128 | 128 | 159 | 190 | 870 | 1 021 |
European reference heating season under average, colder and warmer climate conditions for heat pump space heaters and heat pump combination heaters
binj | Tj [°C] | Average climate conditions | Colder climate conditions | Warmer climate conditions |
---|---|---|---|---|
Hj [h/annum] | Hj [h/annum] | Hj [h/annum] | ||
1 to 8 | –30 to –23 | 0 | 0 | 0 |
9 | -22 | 0 | 1 | 0 |
10 | -21 | 0 | 6 | 0 |
11 | -20 | 0 | 13 | 0 |
12 | -19 | 0 | 17 | 0 |
13 | -18 | 0 | 19 | 0 |
14 | -17 | 0 | 26 | 0 |
15 | -16 | 0 | 39 | 0 |
16 | -15 | 0 | 41 | 0 |
17 | -14 | 0 | 35 | 0 |
18 | -13 | 0 | 52 | 0 |
19 | -12 | 0 | 37 | 0 |
20 | -11 | 0 | 41 | 0 |
21 | -10 | 1 | 43 | 0 |
22 | -9 | 25 | 54 | 0 |
23 | -8 | 23 | 90 | 0 |
24 | -7 | 24 | 125 | 0 |
25 | -6 | 27 | 169 | 0 |
26 | -5 | 68 | 195 | 0 |
27 | -4 | 91 | 278 | 0 |
28 | -3 | 89 | 306 | 0 |
29 | -2 | 165 | 454 | 0 |
30 | -1 | 173 | 385 | 0 |
31 | 0 | 240 | 490 | 0 |
32 | 1 | 280 | 533 | 0 |
33 | 2 | 320 | 380 | 3 |
34 | 3 | 357 | 228 | 22 |
35 | 4 | 356 | 261 | 63 |
36 | 5 | 303 | 279 | 63 |
37 | 6 | 330 | 229 | 175 |
38 | 7 | 326 | 269 | 162 |
39 | 8 | 348 | 233 | 259 |
40 | 9 | 335 | 230 | 360 |
41 | 10 | 315 | 243 | 428 |
42 | 11 | 215 | 191 | 430 |
43 | 12 | 169 | 146 | 503 |
44 | 13 | 151 | 150 | 444 |
45 | 14 | 105 | 97 | 384 |
46 | 15 | 74 | 61 | 294 |
Total hours: | 4 910 | 6 446 | 3 590 |
Average daytime temperature [°C]
January | February | March | April | May | June | July | August | September | October | November | December | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Average climate conditions | 2,8 | 2,6 | 7,4 | 12,2 | 16,3 | 19,8 | 21,0 | 22,0 | 17,0 | 11,9 | 5,6 | 3,2 |
Average global solar irradiance [W/m2]
January | February | March | April | May | June | July | August | September | October | November | December | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Average climate conditions | 70 | 104 | 149 | 192 | 221 | 222 | 232 | 217 | 176 | 129 | 80 | 56 |
Water heating load profiles of combination heaters
h | 3XS | XXS | XS | S | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Qtap | f | Tm | Qtap | f | Tm | Qtap | f | Tm | Qtap | f | Tm | Tp | |
kWh | l/min | °C | kWh | l/min | °C | kWh | l/min | °C | kWh | l/min | °C | °C | |
07:00 | 0,015 | 2 | 25 | 0,105 | 2 | 25 | 0,105 | 3 | 25 | ||||
07:05 | 0,015 | 2 | 25 | ||||||||||
07:15 | 0,015 | 2 | 25 | ||||||||||
07:26 | 0,015 | 2 | 25 | ||||||||||
07:30 | 0,015 | 2 | 25 | 0,105 | 2 | 25 | 0,525 | 3 | 35 | 0,105 | 3 | 25 | |
07:45 | |||||||||||||
08:01 | |||||||||||||
08:05 | |||||||||||||
08:15 | |||||||||||||
08:25 | |||||||||||||
08:30 | 0,105 | 2 | 25 | 0,105 | 3 | 25 | |||||||
08:45 | |||||||||||||
09:00 | 0,015 | 2 | 25 | ||||||||||
09:30 | 0,015 | 2 | 25 | 0,105 | 2 | 25 | 0,105 | 3 | 25 | ||||
10:00 | |||||||||||||
10:30 | |||||||||||||
11:00 | |||||||||||||
11:30 | 0,015 | 2 | 25 | 0,105 | 2 | 25 | 0,105 | 3 | 25 | ||||
11:45 | 0,015 | 2 | 25 | 0,105 | 2 | 25 | 0,105 | 3 | 25 | ||||
12:00 | 0,015 | 2 | 25 | 0,105 | 2 | 25 | |||||||
12:30 | 0,015 | 2 | 25 | 0,105 | 2 | 25 | |||||||
12:45 | 0,015 | 2 | 25 | 0,105 | 2 | 25 | 0,525 | 3 | 35 | 0,315 | 4 | 10 | 55 |
14:30 | 0,015 | 2 | 25 | ||||||||||
15:00 | 0,015 | 2 | 25 | ||||||||||
15:30 | 0,015 | 2 | 25 | ||||||||||
16:00 | 0,015 | 2 | 25 | ||||||||||
16:30 | |||||||||||||
17:00 | |||||||||||||
18:00 | 0,105 | 2 | 25 | 0,105 | 3 | 25 | |||||||
18:15 | 0,105 | 2 | 25 | 0,105 | 3 | 40 | |||||||
18:30 | 0,015 | 2 | 25 | 0,105 | 2 | 25 | |||||||
19:00 | 0,015 | 2 | 25 | 0,105 | 2 | 25 | |||||||
19:30 | 0,015 | 2 | 25 | 0,105 | 2 | 25 | |||||||
20:00 | 0,105 | 2 | 25 | ||||||||||
20:30 | 1,05 | 3 | 35 | 0,42 | 4 | 10 | 55 | ||||||
20:45 | 0,105 | 2 | 25 | ||||||||||
20:46 | |||||||||||||
21:00 | 0,105 | 2 | 25 | ||||||||||
21:15 | 0,015 | 2 | 25 | 0,105 | 2 | 25 | |||||||
21:30 | 0,015 | 2 | 25 | 0,525 | 5 | 45 | |||||||
21:35 | 0,015 | 2 | 25 | 0,105 | 2 | 25 | |||||||
21:45 | 0,015 | 2 | 25 | 0,105 | 2 | 25 | |||||||
Qref | 0,345 | 2,1 | 2,1 | 2,1 |
Water heating load profiles of combination heaters
h | M | L | XL | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Qtap | f | Tm | Tp | Qtap | f | Tm | Tp | Qtap | f | Tm | Tp | |
kWh | l/min | °C | °C | kWh | l/min | °C | °C | kWh | l/min | °C | °C | |
07:00 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | |||
07:05 | 1,4 | 6 | 40 | 1,4 | 6 | 40 | ||||||
07:15 | 1,82 | 6 | 40 | |||||||||
07:26 | 0,105 | 3 | 25 | |||||||||
07:30 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | ||||||
07:45 | 0,105 | 3 | 25 | 4,42 | 10 | 10 | 40 | |||||
08:01 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | ||||||
08:05 | 3,605 | 10 | 10 | 40 | ||||||||
08:15 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | ||||||
08:25 | 0,105 | 3 | 25 | |||||||||
08:30 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | |||
08:45 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | |||
09:00 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | |||
09:30 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | |||
10:00 | 0,105 | 3 | 25 | |||||||||
10:30 | 0,105 | 3 | 10 | 40 | 0,105 | 3 | 10 | 40 | 0,105 | 3 | 10 | 40 |
11:00 | 0,105 | 3 | 25 | |||||||||
11:30 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | |||
11:45 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | |||
12:00 | ||||||||||||
12:30 | ||||||||||||
12:45 | 0,315 | 4 | 10 | 55 | 0,315 | 4 | 10 | 55 | 0,735 | 4 | 10 | 55 |
14:30 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | |||
15:00 | 0,105 | 3 | 25 | |||||||||
15:30 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | |||
16:00 | 0,105 | 3 | 25 | |||||||||
16:30 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | |||
17:00 | 0,105 | 3 | 25 | |||||||||
18:00 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | |||
18:15 | 0,105 | 3 | 40 | 0,105 | 3 | 40 | 0,105 | 3 | 40 | |||
18:30 | 0,105 | 3 | 40 | 0,105 | 3 | 40 | 0,105 | 3 | 40 | |||
19:00 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | |||
19:30 | ||||||||||||
20:00 | ||||||||||||
20:30 | 0,735 | 4 | 10 | 55 | 0,735 | 4 | 10 | 55 | 0,735 | 4 | 10 | 55 |
20:45 | ||||||||||||
20:46 | 4,42 | 10 | 10 | 40 | ||||||||
21:00 | 3,605 | 10 | 10 | 40 | ||||||||
21:15 | 0,105 | 3 | 25 | 0,105 | 3 | 25 | ||||||
21:30 | 1,4 | 6 | 40 | 0,105 | 3 | 25 | 4,42 | 10 | 10 | 40 | ||
21:35 | ||||||||||||
21:45 | ||||||||||||
Qref | 5,845 | 11,655 | 19,07 |
Water heating load profiles of combination heaters
h | XXL | |||
---|---|---|---|---|
Qtap | f | Tm | Tp | |
kWh | l/min | °C | °C | |
07:00 | 0,105 | 3 | 25 | |
07:05 | ||||
07:15 | 1,82 | 6 | 40 | |
07:26 | 0,105 | 3 | 25 | |
07:30 | ||||
07:45 | 6,24 | 16 | 10 | 40 |
08:01 | 0,105 | 3 | 25 | |
08:05 | ||||
08:15 | 0,105 | 3 | 25 | |
08:25 | ||||
08:30 | 0,105 | 3 | 25 | |
08:45 | 0,105 | 3 | 25 | |
09:00 | 0,105 | 3 | 25 | |
09:30 | 0,105 | 3 | 25 | |
10:00 | 0,105 | 3 | 25 | |
10:30 | 0,105 | 3 | 10 | 40 |
11:00 | 0,105 | 3 | 25 | |
11:30 | 0,105 | 3 | 25 | |
11:45 | 0,105 | 3 | 25 | |
12:00 | ||||
12:30 | ||||
12:45 | 0,735 | 4 | 10 | 55 |
14:30 | 0,105 | 3 | 25 | |
15:00 | 0,105 | 3 | 25 | |
15:30 | 0,105 | 3 | 25 | |
16:00 | 0,105 | 3 | 25 | |
16:30 | 0,105 | 3 | 25 | |
17:00 | 0,105 | 3 | 25 | |
18:00 | 0,105 | 3 | 25 | |
18:15 | 0,105 | 3 | 40 | |
18:30 | 0,105 | 3 | 40 | |
19:00 | 0,105 | 3 | 25 | |
19:30 | ||||
20:00 | ||||
20:30 | 0,735 | 4 | 10 | 55 |
20:45 | ||||
20:46 | 6,24 | 16 | 10 | 40 |
21:00 | ||||
21:15 | 0,105 | 3 | 25 | |
21:30 | 6,24 | 16 | 10 | 40 |
21:35 | ||||
21:45 | ||||
Qref | 24,53 |
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As adopted by EU): The original version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: