- Latest available (Revised)
- Original (As adopted by EU)
Commission Delegated Regulation (EU) No 811/2013 of 18 February 2013 supplementing Directive 2010/30/EU of the European Parliament and of the Council with regard to the energy labelling of space heaters, combination heaters, packages of space heater, temperature control and solar device and packages of combination heater, temperature control and solar device (Text with EEA relevance)
When the UK left the EU, legislation.gov.uk published EU legislation that had been published by the EU up to IP completion day (31 December 2020 11.00 p.m.). On legislation.gov.uk, these items of legislation are kept up-to-date with any amendments made by the UK since then.
Legislation.gov.uk publishes the UK version. EUR-Lex publishes the EU version. The EU Exit Web Archive holds a snapshot of EUR-Lex’s version from IP completion day (31 December 2020 11.00 p.m.).
This is the original version as it was originally adopted in the EU.
This legislation may since have been updated - see the latest available (revised) version
The seasonal space heating energy efficiency class of a heater, with the exception of low-temperature heat pumps and heat pump space heaters for low-temperature application, shall be determined on the basis of its seasonal space heating energy efficiency as set out in Table 1.
The seasonal space heating energy efficiency classes of a low-temperature heat pump and a heat pump space heater for low-temperature application shall be determined on the basis of its seasonal space heating energy efficiency as set out in Table 2.
The seasonal space heating energy efficiency of a heater shall be calculated in accordance with points 3 and 4 of Annex VII, for heat pump space heaters, heat pump combination heaters and low-temperature heat pumps under average climate conditions.
Seasonal space heating energy efficiency classes of heaters, with the exception of low-temperature heat pumps and heat pump space heaters for low-temperature application
Seasonal space heating energy efficiency class | Seasonal space heating energy efficiency ηs in % |
---|---|
A+++ | ηs ≥ 150 |
A++ | 125 ≤ ηs < 150 |
A+ | 98 ≤ ηs < 125 |
A | 90 ≤ ηs < 98 |
B | 82 ≤ ηs < 90 |
C | 75 ≤ ηs < 82 |
D | 36 ≤ ηs < 75 |
E | 34 ≤ ηs < 36 |
F | 30 ≤ ηs < 34 |
G | ηs < 30 |
Seasonal space heating energy efficiency classes of low-temperature heat pumps and heat pump space heaters for low-temperature application
Seasonal space heating energy efficiency class | Seasonal space heating energy efficiency ηs in % |
---|---|
A+++ | ηs ≥ 175 |
A++ | 150 ≤ ηs < 175 |
A+ | 123 ≤ ηs < 150 |
A | 115 ≤ ηs < 123 |
B | 107 ≤ ηs < 115 |
C | 100 ≤ ηs < 107 |
D | 61 ≤ ηs < 100 |
E | 59 ≤ ηs < 61 |
F | 55 ≤ ηs < 59 |
G | ηs < 55 |
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As adopted by EU): The original version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: