Search Legislation

Directive 2013/35/EU of the European Parliament and of the CouncilShow full title

Directive 2013/35/EU of the European Parliament and of the Council of 26 June 2013 on the minimum health and safety requirements regarding the exposure of workers to the risks arising from physical agents (electromagnetic fields) (20th individual Directive within the meaning of Article 16(1) of Directive 89/391/EEC) and repealing Directive 2004/40/EC

 Help about what version

What Version

 Help about UK-EU Regulation

Legislation originating from the EU

When the UK left the EU, legislation.gov.uk published EU legislation that had been published by the EU up to IP completion day (31 December 2020 11.00 p.m.). On legislation.gov.uk, these items of legislation are kept up-to-date with any amendments made by the UK since then.

Close

This item of legislation originated from the EU

Legislation.gov.uk publishes the UK version. EUR-Lex publishes the EU version. The EU Exit Web Archive holds a snapshot of EUR-Lex’s version from IP completion day (31 December 2020 11.00 p.m.).

Status:

This is the original version (as it was originally adopted).

ANNEX III

THERMAL EFFECTS EXPOSURE LIMIT VALUES AND ACTION LEVELS IN THE FREQUENCY RANGE FROM 100 kHz TO 300 GHz

A.EXPOSURE LIMIT VALUES (ELVs)

Health effects ELVs for frequencies from 100 kHz to 6 GHz (Table A1) are limits for energy and power absorbed per unit mass of body tissue generated from exposure to electric and magnetic fields.

Sensory effects ELVs for frequencies from 0,3 to 6 GHz (Table A2) are limits on absorbed energy in a small mass of tissue in the head from exposure to electromagnetic fields.

Health effects ELVs for frequencies above 6 GHz (Table A3) are limits for power density of an electromagnetic wave incident on the body surface.

Table A1

Health effects ELVs for exposure to electromagnetic fields from 100 kHz to 6 GHz

Health effects ELVsSAR values averaged over any six-minute period
ELVs related to whole body heat stress expressed as averaged SAR in the body0,4 Wkg–1
ELVs related to localised heat stress in head and trunk expressed as localised SAR in the body10 Wkg–1
ELVs related to localised heat stress in the limbs expressed as localised SAR in the limbs20 Wkg–1
Note A1-1:Localised SAR averaging mass is any 10 g of contiguous tissue; the maximum SAR so obtained should be the value used for estimating exposure. This 10 g of tissue is intended to be a mass of contiguous tissue with roughly homogeneous electrical properties. In specifying a contiguous mass of tissue, it is recognised that this concept may be used in computational dosimetry but may present difficulties for direct physical measurements. A simple geometry, such as cubic or spheric tissue mass, can be used.

Sensory effects ELVs from 0,3 GHz to 6 GHz

This sensory effects ELVs (Table A2) is related to avoiding auditory effects caused by exposures of the head to pulsed microwave radiation.

Table A2

Sensory effects ELVs for exposure to electromagnetic fields from 0,3 to 6 GHz

Frequency rangeLocalised specific energy absorption (SA)
0,3 ≤ f ≤ 6 GHz10 mJkg–1
Note A2-1:Localised SA averaging mass is 10 g of tissue.
Table A3

Health effects ELVs for exposure to electromagnetic fields from 6 to 300 GHz

Frequency rangeHealth effects ELVs related to power density
6 ≤ f ≤ 300 GHz50 Wm–2
Note A3-1:The power density shall be averaged over any 20 cm2 of exposed area. Spatial maximum power densities averaged over 1 cm2 should not exceed 20 times the value of 50 Wm–2. Power densities from 6 to 10 GHz are to be averaged over any six-minute period. Above 10 GHz, the power density shall be averaged over any 68/f1,05-minute period (where f is the frequency in GHz) to compensate for progressively shorter penetration depth, as the frequency increases.

B.ACTION LEVELS (ALs)

The following physical quantities and values are used to specify the action levels (ALs), the magnitude of which are established to ensure by simplified assessment the compliance with the relevant ELVs or at which relevant protection or prevention measures specified in Article 5 must be taken:

  • ALs(E) for electric field strength E of time varying electric field, as specified in Table B1;

  • ALs(B) for magnetic flux density B of time varying magnetic field, as specified in Table B1;

  • ALs(S) for power density of electromagnetic waves, as specified in Table B1;

  • ALs(IC) for contact current, as specified in Table B2;

  • ALs(IL) for limb current, as specified in Table B2;

ALs correspond to calculated or measured field values at the workplace in the absence of the worker, as maximum value at the position of the body or specified part of the body.

Action levels (ALs) for exposure to electric and magnetic fields

ALs(E) and ALs(B) are derived from the SAR or power density ELVs (Tables A1 and A3) based on the thresholds related to internal thermal effects caused by exposure to (external) electric and magnetic fields.

Table B1

ALs for exposure to electric and magnetic fields from 100 kHz to 300 GHz

Frequency rangeElectric field strength ALs(E) [Vm–1] (RMS)Magnetic flux density ALs(B) [μT] (RMS)Power density ALs(S) [Wm–2]
100 kHz ≤ f < 1 MHz6,1 × 1022,0 × 106/f
1≤ f < 10 MHz6,1 × 108/f2,0 × 106/f
10 ≤ f < 400 MHz610,2
400 MHz ≤ f < 2 GHz3 × 10–3 f½1,0 × 10–5 f½
2 ≤ f < 6 GHz1,4 × 1024,5 × 10–1
6 ≤ f ≤ 300 GHz1,4 × 1024,5 × 10–150
Note B1-1:f is the frequency expressed in hertz (Hz).
Note B1-2:[ALs(E)]2 and [ALs(B)]2 are to be averaged over a six-minute period. For RF pulses, the peak power density averaged over the pulse width shall not exceed 1 000 times the respective ALs(S) value. For multi-frequency fields, the analysis shall be based on summation, as explained in the practical guides referred to in Article 14.
Note B1-3:ALs(E) and ALs(B) represent maximum calculated or measured values at the workers’ body position. This results in a conservative exposure assessment and automatic compliance with ELVs in all non-uniform exposure conditions. In order to simplify the assessment of compliance with ELVs, carried out in accordance with Article 4, in specific non-uniform conditions, criteria for the spatial averaging of measured fields based on established dosimetry will be laid down in the practical guides referred to in Article 14. In the case of a very localised source within a distance of a few centimetres from the body, compliance with ELVs shall be determined dosimetrically, case by case.
Note B1-4:The power density shall be averaged over any 20 cm2 of exposed area. Spatial maximum power densities averaged over 1 cm2 should not exceed 20 times the value of 50 Wm–2. Power densities from 6 to 10 GHz are to be averaged over any six-minute period. Above 10 GHz, the power density shall be averaged over any 68/f1,05-minute period (where f is the frequency in GHz) to compensate for progressively shorter penetration depth as the frequency increases.
Table B2

ALs for steady state contact currents and induced limb currents

Frequency rangeSteady state contact current, ALs(IC) [mA] (RMS)Induced limb current in any limb, ALs(IL) [mA] (RMS)
100 kHz ≤ f < 10 MHz40
10 ≤ f ≤ 110 MHz40100
Note B2-1:[ALs(IL)]2 is to be averaged over a six-minute period.

Back to top

Options/Help

Print Options

Close

Legislation is available in different versions:

Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.

Original (As adopted by EU): The original version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.

Close

Opening Options

Different options to open legislation in order to view more content on screen at once

Close

More Resources

Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as adopted version that was used for the EU Official Journal
  • lists of changes made by and/or affecting this legislation item
  • all formats of all associated documents
  • correction slips
  • links to related legislation and further information resources
Close

More Resources

Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as adopted version that was used for the print copy
  • correction slips

Click 'View More' or select 'More Resources' tab for additional information including:

  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • links to related legislation and further information resources