Search Legislation

Directive 2008/50/EC of the European Parliament and of the CouncilShow full title

Directive 2008/50/EC of the European Parliament and of the Council of 21 May 2008 on ambient air quality and cleaner air for Europe

 Help about what version

What Version

More Resources

 Help about UK-EU Regulation

Legislation originating from the EU

When the UK left the EU, legislation.gov.uk published EU legislation that had been published by the EU up to IP completion day (31 December 2020 11.00 p.m.). On legislation.gov.uk, these items of legislation are kept up-to-date with any amendments made by the UK since then.

Close

This item of legislation originated from the EU

Legislation.gov.uk publishes the UK version. EUR-Lex publishes the EU version. The EU Exit Web Archive holds a snapshot of EUR-Lex’s version from IP completion day (31 December 2020 11.00 p.m.).

Status:

This is the original version (as it was originally adopted).

ANNEX IDATA QUALITY OBJECTIVES

A.Data quality objectives for ambient air quality assessment

a

Member States may apply random measurements instead of continuous measurements for benzene, lead and particulate matter if they can demonstrate to the Commission that the uncertainty, including the uncertainty due to random sampling, meets the quality objective of 25 % and the time coverage is still larger than the minimum time coverage for indicative measurements. Random sampling must be evenly distributed over the year in order to avoid skewing of results. The uncertainty due to random sampling may be determined by the procedure laid down in ISO 11222 (2002) ‘Air Quality — Determination of the Uncertainty of the Time Average of Air Quality Measurements’. If random measurements are used to assess the requirements of the PM10 limit value, the 90,4 percentile (to be lower than or equal to 50 µg/m3) should be evaluated instead of the number of exceedances, which is highly influenced by data coverage.

b

Distributed over the year to be representative of various conditions for climate and traffic.

c

One day's measurement a week at random, evenly distributed over the year, or eight weeks evenly distributed over the year.

d

One measurement a week at random, evenly distributed over the year, or eight weeks evenly distributed over the year.

Sulphur dioxide, nitrogen dioxide and oxides of nitrogen and carbon monoxideBenzeneParticulate matter (PM10/PM2,5) and leadOzone and related NO and NO2
Fixed measurementsa
Uncertainty15 %25 %25 %15 %
Minimum data capture90 %90 %90 %

90 % during summer

75 % during winter

Minimum time coverage:
urban background and traffic
35 %b
industrial sites
90 %
Indicative measurements
Uncertainty25 %30 %50 %30 %
Minimum data capture90 %90 %90 %90 %
Minimum time coverage14 %d14 %c14 %d> 10 % during summer
Modelling uncertainty:
Hourly50 %50 %
Eight-hour averages50 %50 %
Daily averages50 %not yet defined
Annual averages30 %50 %50 %
Objective estimation
Uncertainty75 %100 %100 %75 %

The uncertainty (expressed at a 95 % confidence level) of the assessment methods will be evaluated in accordance with the principles of the CEN Guide to the Expression of Uncertainty in Measurement (ENV 13005-1999), the methodology of ISO 5725:1994 and the guidance provided in the CEN report ‘Air Quality — Approach to Uncertainty Estimation for Ambient Air Reference Measurement Methods’ (CR 14377:2002E). The percentages for uncertainty in the above table are given for individual measurements averaged over the period considered by the limit value (or target value in the case of ozone), for a 95 % confidence interval. The uncertainty for the fixed measurements shall be interpreted as being applicable in the region of the appropriate limit value (or target value in the case of ozone).

The uncertainty for modelling is defined as the maximum deviation of the measured and calculated concentration levels for 90 % of individual monitoring points, over the period considered, by the limit value (or target value in the case of ozone), without taking into account the timing of the events. The uncertainty for modelling shall be interpreted as being applicable in the region of the appropriate limit value (or target value in the case of ozone). The fixed measurements that have to be selected for comparison with modelling results shall be representative of the scale covered by the model.

The uncertainty for objective estimation is defined as the maximum deviation of the measured and calculated concentration levels, over the period considered, by the limit value (or target value in the case of ozone), without taking into account the timing of the events.

The requirements for minimum data capture and time coverage do not include losses of data due to the regular calibration or the normal maintenance of the instrumentation.

B.Results of air quality assessment

The following information shall be compiled for zones or agglomerations within which sources other than measurement are employed to supplement information from measurement or as the sole means of air quality assessment:

  • a description of assessment activities carried out,

  • the specific methods used, with references to descriptions of the method,

  • the sources of data and information,

  • a description of results, including uncertainties and, in particular, the extent of any area or, if relevant, the length of road within the zone or agglomeration over which concentrations exceed any limit value, target value or long-term objective plus margin of tolerance, if applicable, and of any area within which concentrations exceed the upper assessment threshold or the lower assessment threshold,

  • the population potentially exposed to levels in excess of any limit value for protection of human health.

C.Quality assurance for ambient air quality assessment: data validation

1.To ensure accuracy of measurements and compliance with the data quality objectives laid down in Section A, the appropriate competent authorities and bodies designated pursuant to Article 3 shall ensure the following:

  • that all measurements undertaken in relation to the assessment of ambient air quality pursuant to Articles 6 and 9 are traceable in accordance with the requirements set out in Section 5.6.2.2 of the ISO/IEC 17025:2005,

  • that institutions operating networks and individual stations have an established quality assurance and quality control system which provides for regular maintenance to assure the accuracy of measuring devices,

  • that a quality assurance/quality control process is established for the process of data collection and reporting and that institutions appointed for this task actively participate in the related Community-wide quality assurance programmes,

  • that the national laboratories, when appointed by the appropriate competent authority or body designated pursuant to Article 3, that are taking part in Community-wide intercomparisons covering pollutants regulated in this Directive, are accredited according to EN/ISO 17025 by 2010 for the reference methods referred to in Annex VI. These laboratories shall be involved in the coordination on Member States territory of the Community wide quality assurance programmes to be organised by the Commission and shall also coordinate, on the national level, the appropriate realisation of reference methods and the demonstration of equivalence of non-reference methods.

2.All reported data under Article 27 shall be deemed to be valid except data flagged as provisional.

Back to top

Options/Help

Print Options

Close

Legislation is available in different versions:

Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.

Original (As adopted by EU): The original version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.

Close

Opening Options

Different options to open legislation in order to view more content on screen at once

Close

More Resources

Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as adopted version that was used for the EU Official Journal
  • lists of changes made by and/or affecting this legislation item
  • all formats of all associated documents
  • correction slips
  • links to related legislation and further information resources
Close

More Resources

Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as adopted version that was used for the print copy
  • correction slips

Click 'View More' or select 'More Resources' tab for additional information including:

  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • links to related legislation and further information resources