The monitoring and maintenance of fixed or movable components that are involved in train movements must be organised, carried out and quantified in such a manner as to maintain their operation under the intended conditions.
The technical characteristics of the infrastructure and fixed installations must be compatible with each other and with those of the trains to be used on the trans-European conventional rail system.
If compliance with these characteristics proves difficult on certain sections of the network, temporary solutions, which ensure compatibility in the future, may be implemented.
Appropriate steps must be taken to prevent access to or undesirable intrusions into installations.
Steps must be taken to limit the dangers to which persons are exposed, particularly when trains pass through stations.
Infrastructure to which the public has access must be designed and made in such a way as to limit any human safety hazards (stability, fire, access, evacuation, platforms, etc.).
Appropriate provisions must be laid down to take account of the particular safety conditions in very long tunnels.
Operation of the energy-supply systems must not impair the safety either of trains or of persons (users, operating staff, trackside dwellers and third parties).
The functioning of the electrical or thermal energy-supply systems must not interfere with the environment beyond the specified limits.
The electricity/thermal energy supply systems used must:
enable trains to achieve the specified performance levels;
in the case of electricity energy supply systems, be compatible with the collection devices fitted to the trains.
The control and command and signalling installations and procedures used must enable trains to travel with a level of safety which corresponds to the objectives set for the network. The control and command and signalling systems should continue to provide for safe passage of trains permitted to run under degraded conditions.
All new infrastructure and all new rolling stock manufactured or developed after adoption of compatible control and command and signalling systems must be tailored to use of those systems.
The control and command and signalling equipment installed in the train drivers' cabs must permit normal operation, under the specified conditions, throughout the trans-European conventional rail system.
The structure of the rolling stock and of the links between vehicles must be designed in such a way as to protect the passenger and driving compartments in the event of collision or derailment.
The electrical equipment must not impair the safety and functioning of the control and command and signalling installations.
The braking techniques and the stresses exerted must be compatible with the design of the track, engineering structures and signalling systems.
Steps must be taken to prevent access to electrically-live constituents in order not to endanger the safety of persons.
In the event of danger, devices must enable passengers to inform the driver and accompanying staff to contact him.
The access doors must incorporate an opening and closing system which guarantees passenger safety.
Emergency exits must be provided and indicated.
Appropriate provisions must be laid down to take account of the particular safety conditions in very long tunnels.
An emergency lighting system of sufficient intensity and duration is compulsory on board trains.
Trains must be equipped with a public address system which provides a means of communication to the public from on-board staff and ground control.
The design of the vital equipment, of the running, traction and braking equipment and of the control and command system must be such as to enable the train to continue its mission, in a specific degraded situation, without adverse consequences for the equipment remaining in service.
The electrical equipment must be compatible with the operation of the control and command and signalling installations.
In the case of electric traction, the characteristics of the current-collection devices must be such as to enable trains to travel under the energy-supply systems for the trans-European conventional rail system.
The characteristics of the rolling stock must be such as to allow it to travel on any line on which it is expected to operate.
The technical installations and the procedures used in the centres must ensure the safe operation of the subsystem and not constitute a danger to health and safety.
The technical installations and the procedures used in the maintenance centres must not exceed the permissible levels of nuisance with regard to the surrounding environment.
The maintenance installations for conventional rolling stock must be such as to enable safety, health and comfort operations to be carried out on all stock for which they have been designed.
Alignment of the network operating rules and the qualifications of drivers and on-board staff and of the staff in the control centres must be such as to ensure safe operation, bearing in mind the different requirements of cross-border and domestic services.
The maintenance operations and intervals, the training and qualifications of the maintenance and control centre staff and the quality assurance system set up by the operators concerned in the control and maintenance centres must be such as to ensure a high level of safety.
The maintenance operations and periods, the training and qualifications of the maintenance and control centre staff and the quality assurance system set up by the operators concerned in the control and maintenance centres must be such as to ensure a high level of system reliability and availability.
Alignment of the network operating rules and the qualifications of drivers, on-board staff and traffic managers must be such as to ensure operating efficiency on the trans-European conventional rail system, bearing in mind the different requirements of cross-border and domestic services.
The essential requirements for telematics applications guarantee a minimum quality of service for passengers and carriers of goods, particularly in terms of technical compatibility.
Steps must be taken to ensure:
that the databases, software and data communication protocols are developed in a manner allowing maximum data interchange between different applications and operators, excluding confidential commercial data;
easy access to the information for users.
The methods of use, management, updating and maintenance of these databases, software and data communication protocols must guarantee the efficiency of these systems and the quality of the service.
The interfaces between these systems and users must comply with the minimum rules on ergonomics and health protection.
Suitable levels of integrity and dependability must be provided for the storage or transmission of safety-related information.
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As adopted by EU): The original version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: