Search Legislation

Directive 1999/2/EC of the European Parliament and of the CouncilShow full title

Directive 1999/2/EC of the European Parliament and of the Council of 22 February 1999 on the approximation of the laws of the Member States concerning foods and food ingredients treated with ionising radiation

 Help about what version

What Version

  • Latest available (Revised)
  • Original (As adopted by EU)
 Help about advanced features

Advanced Features

More Resources

 Help about UK-EU Regulation

Legislation originating from the EU

When the UK left the EU, legislation.gov.uk published EU legislation that had been published by the EU up to IP completion day (31 December 2020 11.00 p.m.). On legislation.gov.uk, these items of legislation are kept up-to-date with any amendments made by the UK since then.

Close

This item of legislation originated from the EU

Legislation.gov.uk publishes the UK version. EUR-Lex publishes the EU version. The EU Exit Web Archive holds a snapshot of EUR-Lex’s version from IP completion day (31 December 2020 11.00 p.m.).

Status:

EU Directives are published on this site to aid cross referencing from UK legislation. Since IP completion day (31 December 2020 11.00 p.m.) no amendments have been applied to this version.

ANNEX IIIU.K.

1.DOSIMETRYU.K.

Overall average absorbed dose

It can be assumed for the purpose of the determination of the wholesomeness of foodstuffs treated with an overall average dose of 10 kGy or less that all radiation chemical effects in that particular dose range are proportional to the dose.

The overall average dose,

, is defined by the following integral over the total volume of the goods:

where

M

=

the total mass of the treated sample

p

=

the local density at the point (x,y,z)

d

=

the local absorbed dose at the point (x,y,z)

dV

=

dx dy dz, the infinitesimal volume element which in real cases is represented by the volume fractions.

The overall average absorbed dose can be determined directly for homogenous products or for bulk goods of homogenous apparent density by distributing an adequate number of dosimeters strategically and at random throughout the volume of the goods. From the dose distribution determined in this manner an average can be calculated which is the overall average absorbed dose.

If the shape of the dose distribution curve through the product is well determined, the positions of minimum and maximum dose are known. Measurements of the distribution of dose in these two positions in a series of samples of the product can be used to give an estimate of the overall average dose.

In some cases, the mean value of the average values of the minimum dose (

) and maximum dose (

) will be a good estimate of the overall dose: i.e., in these cases:

The ratio of should not exceed 3.

2.PROCEDURESU.K.

2.1.Before routine irradiation of a given category of foodstuff begins at a radiation facility, the locations of the minimum and maximum doses are determined by making dose measurements throughout the product volume. These validation measurements must be carried out a suitable number of times (e.g. 3-5) in order to make allowance for variations in product density or geometry.U.K.

2.2.Measurements must be repeated whenever the product, its geometry or the irradiation conditions are changed.U.K.

2.3.During the process, routine dose measurements are carried out in order to ensure that the dose limits are not exceeded. Measurements should be carried out by placing dosimeters at the positions of the maximum or minimum dose, or at a reference position. The dose at the reference position must be quantitatively linked to the maximum and minimum dose. The reference position should be located at a convenient point in or on the product, where dose variations are low.U.K.

2.4.Routine dose measurements must be carried out on each batch and at regular intervals during production.U.K.

2.5.In cases where flowing, non-packaged goods are irradiated, the locations of the minimum and maximum doses cannot be determined. In such a case it is preferable to use random dosimeter sampling to ascertain the values of these dose extremes.U.K.

2.6.Dose measurements should be carried out by using recognised dosimetry systems, and the measurements should be traceable to primary standards.U.K.

2.7.During irradiation, certain facility parameters must be controlled and continuously recorded. For radionuclide facilities the parameters include product transport speed or time spent in the radiation zone and positive indication for correct position of the source. For accelerator facilities, the parameters include product transport speed and energy level, electron current and scanner width of the facility.U.K.

Back to top

Options/Help

Print Options

Close

Legislation is available in different versions:

Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.

Original (As adopted by EU): The original version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.

Close

See additional information alongside the content

Geographical Extent: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.

Show Timeline of Changes: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.

Close

Opening Options

Different options to open legislation in order to view more content on screen at once

Close

More Resources

Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as adopted version that was used for the EU Official Journal
  • lists of changes made by and/or affecting this legislation item
  • all formats of all associated documents
  • correction slips
  • links to related legislation and further information resources
Close

Timeline of Changes

This timeline shows the different versions taken from EUR-Lex before exit day and during the implementation period as well as any subsequent versions created after the implementation period as a result of changes made by UK legislation.

The dates for the EU versions are taken from the document dates on EUR-Lex and may not always coincide with when the changes came into force for the document.

For any versions created after the implementation period as a result of changes made by UK legislation the date will coincide with the earliest date on which the change (e.g an insertion, a repeal or a substitution) that was applied came into force. For further information see our guide to revised legislation on Understanding Legislation.

Close

More Resources

Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as adopted version that was used for the print copy
  • correction slips

Click 'View More' or select 'More Resources' tab for additional information including:

  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • links to related legislation and further information resources