Search Legislation

Council Directive 93/30/EEC (repealed)Show full title

Council Directive 93/30/EEC of 14 June 1993 on audible warning devices for two- or three-wheel motor vehicles (repealed)

 Help about what version

What Version

 Help about UK-EU Regulation

Legislation originating from the EU

When the UK left the EU, legislation.gov.uk published EU legislation that had been published by the EU up to IP completion day (31 December 2020 11.00 p.m.). On legislation.gov.uk, these items of legislation are kept up-to-date with any amendments made by the UK since then.

Close

This item of legislation originated from the EU

Legislation.gov.uk publishes the UK version. EUR-Lex publishes the EU version. The EU Exit Web Archive holds a snapshot of EUR-Lex’s version from IP completion day (31 December 2020 11.00 p.m.).

Status:

This is the original version (as it was originally adopted).

ANNEX IREQUIREMENTS APPLYING TO THE COMPONENT TYPE-APPROVAL OF AUDIBLE WARNING DEVICES

1.DEFINITIONS

For the purposes of this Directive:

1.1.‘audible warning device’ means a device emitting an acoustic signal the operation of which is intended to give warning of the presence of or a manoeuvre by a vehicle in a dangerous road traffic situation;

1.1.1.a device consisting of several sound emission orifices that are excited by a single power source shall be considered to be an audible warning device;

1.1.2.an audible warning device consisting of several components each emitting an acoustic signal and operating simultaneously as a result of actuation by a single control shall be considered to be a single audible warning device;

1.2.‘type of audible warning device’ means audible warning devices not essentially differing among themselves, particularly in respect of the following aspects:

1.2.1.

trade mark or name;

1.2.2.

operating principle;

1.2.3.

type of power supply (direct current, alternating current, compressed air);

1.2.4.

outer shape of the casing;

1.2.5.

shape and dimensions of the diaphragm(s);

1.2.6.

shape or type of the sound emission orifice(s);

1.2.7.

nominal sound frequencies;

1.2.8.

nominal supply voltage;

1.2.9.

in the case of warning devices supplied direct by an external source of compressed air: the nominal operating pressure.

2.REQUIREMENTS

2.1.Audible warning devices must emit a continuous, uniform sound and their sound spectrum shall not vary perceptibly during operation. In the case of warning devices supplied with an alternating current this requirement applies solely at constant generator speed, that speed lying within the range specified in 3.3.2.

2.2.Warning devices must display sound characteristics (spectral distribution of the sound energy, sound pressure level) and mechanical characteristics such that, in the order stated, they pass the tests specified in sections 3 and 4.

3.SOUND LEVEL MEASUREMENTS

3.1.Audible warning devices must preferably be tested in an anechoic environment. They may alternatively be tested in a semi-anechoic chamber or in a cleared outside space. In this case, precautions must be taken in order to avoid reflections off the ground in the measuring area, e.g. by providing a number of absorbent screens. It must be checked that the spherical distortion is no more than 1 dB within a hemisphere having a radius of at least 5 m up to the maximum frequency to be measured, this mainly being in the direction of measurement and at the height of the device and microphone. The ambient noise must be at least 10 dB lower than the sound pressure levels to be measured.

The device submitted for testing and the microphone must be at the same height. That height must lie between 1.15 and 1.25 m. The line of maximum sensitivity of the microphone must coincide with the direction in which the sound level of the warning device is at its highest level.

The microphone must be positioned such that its diaphragm is at a distance of 2 ± 0,01 m from the exit plane of the sound emitted by the device. That same distance from devices having several exits must be determined in relation to the exit plane closest to the microphone.

3.2.The measurements of the sound pressure level must involve the use of a class-1 precision sound level meter meeting the requirements of IEC publication No 651, first edition (1979).

All measurements must be carried out using the ‘rapid’ time constant. The (A) weighting curve must be used to measure the overall sound pressure levels.

The Fourier transform of the sound signal must be used in measuring the emitted-sound spectrum. Alternatively, third octave filters meeting the requirements set out in IEC publication No 225, first edition (1966) may be used.

In that instance the sound pressure level within the 2 500 Hz centre octave frequency band is determined by adding the quadratic means of the sound pressures in the third-octave bands of centre frequencies of 2 000, 2 500 and 3 150 Hz. In all cases only the Fourier transform method may be considered to be a reference method.

3.3.The audible warning device must be supplied with one of the following voltages, as appropriate:

3.3.1.

in the case of audible warning devices receiving direct current a test voltage of 6,5, 13 or 26 volts, measured at the output side of the eletricity source and corresponding to a nominal voltage of 6, 12 or 24 volts respectively;

3.3.2.

where audible warning devices receive direct current that must be supplied by an electrical generator of the type normally used with this type of device. The acoustic characteristics of that type of warning device must be recorded at alternator speeds corresponding to 50, 75 and 100 % of the maximum speed stated by the manufacturer of the alternator for continuous operation. The alternator must be subject to no other electrical load during the test. The durability test described in section 4 must be carried out at a speed stated by the manufacturer of the equipment and selected from the range referred to above.

3.4.If a rectified current is used for the test on an audible warning device receiving direct current, the unsmoothed component of the voltage at its terminals, measured from peak to peak during operation of the warning devices, must not exceed 0,1 volts.

3.5.The resistance of the electrical conductor for audible warning devices receiving direct current, including the resistance of the terminals and contacts, must lie as closely as possible to:

  • 0,05 Ohms for a nominal voltage of 6 V,

  • 0,10 Ohms for a nominal voltage of 12 V,

  • 0,20 Ohms for a nominal voltage of 24 V.

3.6.The audible warning device must be rigidly mounted, using the part or parts intended for that purpose by its manufacturer on a support, the mass of which is at least 10 times greater than that of the warning device to be tested and at least 30 kg. Moreover, the support must be arranged in such a way that the reflections off its walls and the vibrations have no significant effect on the results of the measurements.

3.7.Under the conditions set out above the A-weighted sound level must not exceed the following values:

(a)

115 dB(A) for audible warning devices intended mainly for mopeds, motorcycles and tricycles developing a power of not more than 7 kW;

(b)

118 dB(A) for audible warning devices intended mainly for motorcycles and tricycles developing a power of more than 7 kW.

3.7.1.Moreover the sound pressure level within the 1 800—3 550 Hz frequency band must be higher than that of any frequency component above 3 550 Hz, and in any case be at least:

(a)

90 dB(A) in the case of audible warning devices intended mainly for mopeds;

(b)

95 dB(A) for audible warning devices intended mainly for motorcycles and tricycles developing a power of not more than 7 kW;

(c)

105 dB(A) for audible warning devices intended mainly for motorcycles and tricycles developing a power of more than 7 kW.

3.7.2.Audible warning devices displaying the characteristics described in 3.7.1 (c) may be used on the vehicles described in 3.7.1 (a) and (b) while audible warning devices displaying the sound characteristics described in 3.7.1 (b) may be used on mopeds.

3.8.The characteristics set out above must also be displayed by any audible warning device that has been subjected to the durability test provided for in section 4. The variation in voltage must be either between 115 and 95 % of the rated value for audible warning devices receiving direct current or between 50 and 100 % of the maximum alternator speed stated by the manufacturer of the alternator for continuous operation in the case of audible warning devices receiving alternating current.

3.9.The time lag between actuation and the moment when the sound reaches the minimum value required by section 3.7 must not exceed 0,2 seconds measured at an ambient temperature of 20 ± 5 oC. This requirement applies, in particular, to pneumatic or electro-pneumatic warning devices.

3.10.Under the power supply conditions laid down by their manufacturers pneumatic or electro-pneumatic warning devices must yield the same acoustic performance as those required for electric audible warning devices.

3.11.The minimum values quoted above must be obtained for each of the individual components of any multi-tone device each component part of which may emit sound independently. The maximum overall sound level must be achieved with all of the component parts operating at the same time.

4.DURABILITY TEST

4.1.The audible warning device must be supplied with the nominal voltage at the conductor resistance specified in sections 3.3 to 3.5 and be operated:

  • 10 000 times in the case of warning devices intended mainly for mopeds, motorcycles and tricycles developing a power not exceeding 7 kW,

  • 50 000 times in the case of warning devices intended mainly for motorcycles and tricycles developing a power of more than 7 kW respectively,

at a rate of one second on followed by four seconds off. During the test the audible warning device must be exposed to a forced draught having a speed of rougly 10 m/sec.

4.2.If a test is conducted within an insulated chamber that chamber must be of sufficient volume to ensure normal dissipation of the heat given off by the warning device during the durability test.

4.3.The ambient temperature within the test chamber must lie between + 15 and + 30 oC.

4.4.If, after half the required number of operations, the characteristics of the sound level have altered as compared with before the test the audible warning device may be reset. When the total number of operations required have been completed the audible warning device must successfully complete the test described in section 3, where necessary after being further reset.

4.5.Electro-pneumatic audible warning devices may be lubricated with the oil recommended by their manufacturer every 10 000 operations.

5.COMPONENT TYPE-APPROVAL MARK

5.1.All audible warning devices conforming to the type that has been component type-approved must bear a component type-approval mark meeting the requirements set out in Annex V to Council Directive 92/61/EEC.

Appendix 1Information document in respect of a type of audible warning device intended for two- or three-wheel motor vehicles

(to be attached to the application for component type-approval where this is submitted separately from the application for vehicle type-approval)

Order No (assigned by the applicant): ...

The application for component type-approval in respect of a type of audible warning device intended for two or three-wheel motor vehicles must contain the information set out in Annex II to Council Directive 92/61/EEC, Part A, sections 9.5.1 to 9.5.4.

Appendix 2

Back to top

Options/Help

Print Options

Close

Legislation is available in different versions:

Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.

Original (As adopted by EU): The original version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.

Close

Opening Options

Different options to open legislation in order to view more content on screen at once

Close

More Resources

Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as adopted version that was used for the EU Official Journal
  • lists of changes made by and/or affecting this legislation item
  • all formats of all associated documents
  • correction slips
  • links to related legislation and further information resources
Close

More Resources

Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as adopted version that was used for the print copy
  • correction slips

Click 'View More' or select 'More Resources' tab for additional information including:

  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • links to related legislation and further information resources