Search Legislation

Commission Implementing Decision (EU) 2019/314Show full title

Commission Implementing Decision (EU) 2019/314 of 21 February 2019 on the approval of the technology used in SEG Automotive Germany GmbH High efficient 48V motor generator (BRM) plus 48V/12V DC/DC converter for use in conventional combustion engine and certain hybrid powered passenger cars as an innovative technology for reducing CO2 emissions from passenger cars pursuant to Regulation (EC) No 443/2009 of the European Parliament and of the Council (Text with EEA relevance)

 Help about what version

What Version

 Help about advanced features

Advanced Features

 Help about UK-EU Regulation

This is a Decision originating from the EU

Close

This is a legislation item that originated from the EU

After exit day there will be three versions of this legislation to consult for different purposes. The legislation.gov.uk version is the version that applies in the UK. The EU Version currently on EUR-lex is the version that currently applies in the EU i.e you may need this if you operate a business in the EU.

The web archive version is the official version of this legislation item as it stood on exit day before being published to legislation.gov.uk and any subsequent UK changes and effects applied. The web archive also captured associated case law and other language formats from EUR-Lex.

Changes over time for: Commission Implementing Decision (EU) 2019/314 (Annexes only)

 Help about opening options

Changes to legislation:

There are currently no known outstanding effects for the Commission Implementing Decision (EU) 2019/314. Help about Changes to Legislation

Close

Changes to Legislation

Revised legislation carried on this site may not be fully up to date. At the current time any known changes or effects made by subsequent legislation have been applied to the text of the legislation you are viewing by the editorial team. Please see ‘Frequently Asked Questions’ for details regarding the timescales for which new effects are identified and recorded on this site.

ANNEXU.K. Methodology to determine the CO2 savings of the SEG Automotive Germany GmbH High efficient 48V motor generator (BRM) plus the 48V/12V DC/DC converter fitted in vehicles in compliance with the conditions set out in Article 1

1.INTRODUCTIONU.K.

In order to determine the CO2 emission reductions that can be attributed to the use of the generation function of the SEG Automotive Germany GmbH High efficient 48V motor generator (BRM), hereinafter referred to as 48 V motor generator or motor generator, plus the 48V/12V DC/DC converter, for use in vehicles in compliance with the conditions set out in Article 1, it is necessary to specify the following:

(1)

The test conditions;

(2)

The test equipment;

(3)

The procedure to determine the total efficiency;

(4)

The procedure to determine the CO2 savings;

(5)

The procedure to determine the uncertainty of the CO2 savings.

Two alternative methods can be used to determine the CO2 savings. The methods are described as follows.

2.SYMBOLS, PARAMETERS AND UNITSU.K.

Latin symbols U.K.

CO2 savings [g CO2/km]

CO2

Carbon dioxide

CF

Conversion factor (l/100 km) - (g CO2/km) [gCO2/l] as defined in Table 3

h

Frequency as defined in Table 1

i

Number of operating points

I

Current intensity at which the measurement shall be carried out [A]

l

Number of measurement of the sample for the 48V/12V DC/DC converter

m

Number of measurement of the sample for the 48V motor generator

M

Torque [Nm]

n

Rotational frequency [min– 1] as defined in Table 1

P

Power [W]

Standard deviation of the 48V/12V DC/DC converter efficiency mean [%]

Standard deviation of the 48V motor generator efficiency [%]

Standard deviation of the 48V motor generator efficiency mean [%]

Standard deviation of the total efficiency [%]

Standard deviation of the total CO2 savings [g CO2/km]

U

Test voltage at which the measurement shall be carried out [V]

v

Mean driving speed of the New European Driving Cycle (NEDC) [km/h]

VPe

Consumption of effective power [l/kWh] as defined in Table 2

Greek symbols U.K.

Δ

Difference

ηB

Baseline alternator efficiency [%]

ηDCDC

48V/12V DC/DC converter efficiency [%]

Mean of the 48V/12V DC/DC converter efficiency [%]

ηMG

48V motor generator efficiency [%]

Mean of the 48V motor generator efficiency at operating point i [%]

ηTOT

Total efficiency [%]

Subscripts U.K.

Index (i) refers to operating point

Index (j) refers to measurement of the sample

MG

Motor generator

m

Mechanical

RW

Real-world conditions

TA

Type approval (NEDC) conditions

B

Baseline

3.METHOD 1 (‘SEPARATE METHOD’)U.K.

3.1. Efficiency of the 48V motor generator U.K.

The efficiency of the 48V motor generator shall be determined in accordance with ISO 8854:2012, with the exception of the elements specified in this section.

Evidence shall be provided to the type approval authority that the rotational frequency ranges of the efficient 48V motor generator are consistent with those set out in Table 1. The measurements shall be conducted at different operating points, as set out in Table 1. The efficient 48V motor generator current intensity shall be defined as half of the rated current for all operating points. For each rotational frequency, the voltage and the output current of the motor generator shall be kept constant, the voltage at 52V.

Table 1

Operating points

Operating pointiHolding time[s]Rotational frequencyni [min– 1]Frequencyhi
11 2001 8000,25
21 2003 0000,40
36006 0000,25
430010 0000,10

The efficiency at each operating point shall be calculated in accordance with Formula 1:

Formula 1

All efficiency measurements are to be performed consecutively at least five (5) times. The average of the measurements at each operating point ( ) shall be calculated.

The efficiency of the generation function (ηMG) shall be calculated in accordance with the following Formula 2:

Formula 2

3.2. Efficiency of the 48V/12V DC/DC converter U.K.

The efficiency of the 48V/12V DC/DC converter shall be determined under the following conditions:

  • Output voltage of 14,3V

  • Output current of nominal power of the 48V/12V DC/DC converter divided by 14,3V

The nominal power of the 48V/12V DC/DC converter shall be the continuous output power at the 12V side guaranteed by the manufacturer of the DC/DC converter at the conditions specified in the ISO 8854:2012.

The efficiency of the 48V/12V DC/DC converter shall be measured at least five (5) times consecutively. The average of all the measurements ( ) shall be calculated and used for the calculations laid down in paragraph 3.3.

3.3. Total efficiency and saved mechanical power U.K.

The total efficiency of the 48 V motor generator plus the 48V/12V DC/DC converter shall be calculated using Formula 3:

Formula 3

The 48 V motor generator plus the 48V/12V DC/DC converter generation function lead to saved mechanical power under real-world conditions (ΔPmRW) and type approval NEDC conditions (ΔPmTA) as set out in Formula 4.

Formula 4

ΔPm = ΔPmRW – ΔPmTA

Where the saved mechanical power under real-world conditions (ΔPmRW) shall be calculated in accordance with Formula 5 and the saved mechanical power under type-approval NEDC conditions (ΔPmTA) in accordance with Formula 6:

  • Formula 5

  • Formula 6

where

PRW

:

Power requirement under ‘real-world’ conditions [W], which is estimated at 750W

PTA

:

Power requirement under NEDC type-approval conditions [W], which is estimated at 350W

ηB

:

Efficiency of the baseline alternator [%], which is 67 %

3.4. Calculation of the CO2 savings U.K.

The CO2 savings of the 48 V motor generator plus the 48V/12V DC/DC converter shall be calculated in accordance with Formula 7:

Formula 7

Where:

v

:

Mean driving speed of the NEDC [km/h], which is 33,58 km/h

VPe

:

Consumption of effective power specified in Table 2:

Table 2

Consumption of effective power

Type of engineConsumption of effective power (VPe)[l/kWh]
Petrol0,264
Petrol Turbo0,280
Diesel0,220
CF

:

Conversion factor (l/100 km) - (g CO2/km) [gCO2/l] as defined in Table 3

Table 3

Fuel conversion factor

Type of fuelConversion factor (l/100 km) - (g CO2/km) (CF)[gCO2/l]
Petrol2 330
Diesel2 640

3.5. Calculation of the statistical margin U.K.

The statistical margin of the results of the testing methodology caused by the measurements shall be quantified. For each operating point the standard deviation shall be calculated in accordance with Formula 8:

Formula 8

The standard deviation of the efficiency value of the efficient 48V motor generator ( ) shall be calculated in accordance with Formula 9:

Formula 9

The standard deviation of the efficiency value of the 48V/12V DC/DC converter ( ) shall be calculated in accordance with Formula 10:

Formula 10

The standard deviation of the motor generator efficiency ( ) and of the 48V/12V DC/DC converter ( ) lead to an uncertainty in the CO2 savings ( ). That uncertainty is calculated in accordance with Formula 11:

Formula 11

4.METHOD 2 (‘COMBINED METHOD’)U.K.

4.1. Efficiency of the 48V motor generator plus the 48V/12V DC/DC converter U.K.

The efficiency of the 48V motor generator plus the 48V/12V DC/DC converter shall be determined in accordance with ISO 8854:2012, with the exception of the elements specified in this section.

Evidence shall be provided to the type approval authority that the speed ranges of the efficient 48V motor generator are consistent with those set out in Table 1.

The measurements shall be conducted at different operating points, as set out in Table 1. The efficient 48V motor generator plus the 48V/12V DC/DC converter current intensity shall be defined as half of the rated current of the 48V/12V DC/DC converter for all operating points.

The rated current of the 48V/12V DC/DC converter is defined as the output nominal power of the 48V/12V DC/DC converter divided by 14,3V. The nominal power of the 48V/12V DC/DC converter shall be the continuous output power at the 12V side guaranteed by the manufacturer of the DC/DC converter at the conditions specified in the ISO 8854:2012.

For each speed the voltage and the output current of the motor generator shall be kept constant, the voltage at 52 V.

The efficiency at each operating point shall be calculated in accordance with Formula 12:

Formula 12

All efficiency measurements are to be performed consecutively at least five (5) times. The average of the measurements at each operating point ( ) shall be calculated.

The efficiency of the generation function (ηTOT) shall be calculated in accordance with Formula 13:

Formula 13

The measurement set up has to allow the measurement of the 48V motor generation efficiency alone.

4.2. Demonstration of conservativeness of the 48V motor generator plus 48V/12V DC/DC converter efficiency determination U.K.

In order to use the procedure specified in 4.1 for the determination of ηTOT, it has to be demonstrated that the efficiency of the 48V motor generator alone obtained with the conditions specified in 4.1 is lower than the efficiency obtained with the conditions specified in 3.1.

4.3. Saved mechanical power U.K.

The 48 V motor generator plus the 48V/12V DC/DC converter generation function lead to saved mechanical power under real-world conditions (ΔPmRW) and type approval conditions (ΔPmTA) as set out in Formula 14.

Formula 14

ΔPm = ΔPmRW – ΔPmTA

Where the saved mechanical power under real-world conditions (ΔPmRW) shall be calculated in accordance with Formula 15 and the saved mechanical power under type-approval conditions (ΔPmTA) in accordance with Formula 16:

  • Formula 15

  • Formula 16

where

PRW

:

Power requirement under ‘real-world’ conditions [W], which is estimated at 750W

PTA

:

Power requirement under type-approval NEDC conditions [W], which is estimated at 350W

ηB

:

Efficiency of the baseline alternator [%], which is 67 %

4.4. Calculation of the CO2 savings U.K.

The CO2 savings of the 48 V motor generator plus the 48V/12V DC/DC converter shall be calculated in accordance with Formula 17:

Formula 17

Where:

v

:

Mean driving speed of the NEDC [km/h], which is 33,58 km/h

VPe

:

Consumption of effective power specified in Table 2

CF

:

Conversion factor (l/100 km) - (g CO2/km) [gCO2/l] as defined in Table 3

4.5. Calculation of the statistical margin U.K.

The statistical margin of the results of the testing methodology caused by the measurements shall be quantified. For each operating point the standard deviation shall be calculated in accordance with Formula 18:

Formula 18

The standard deviation of the efficiency value of the efficient 48V motor generator plus the 48V/12V DC/DC converter ( ) shall be calculated in accordance with Formula 19:

Formula 19

The standard deviation of the motor generator and of the 48V/12V DC/DC converter efficiency leads to an uncertainty in the CO2 savings ( ). That uncertainty is calculated in accordance with Formula 20:

Formula 20

5.ROUNDINGU.K.

The calculated CO2 savings value ( ) and the statistical margin of the CO2 saving ( ) must be rounded to a maximum of two decimal places.

Each value used in the calculation of the CO2 savings can be applied unrounded or must be rounded to the minimum number of decimal places which allows the maximum total impact (i.e. combined impact of all rounded values) on the savings to be lower than 0,25 gCO2/km.

6.STATISTICAL SIGNIFICANCE (for both methods)U.K.

It shall be demonstrated for each type, variant and version of a vehicle fitted with the efficient 48V motor generator that the uncertainty of the CO2 savings calculated in accordance with Formula 7 or Formula 17 is not greater than the difference between the total CO2 savings and the minimum savings threshold specified in Article 9(1) of Implementing Regulation (EU) No 725/2011 and Commission Implementing Regulation (EU) No 427/2014(1) (see Formula 21).

Formula 21

Where:

MT

:

minimum threshold [g CO2/km]

:

total CO2 saving [g CO2/km]

:

standard deviation of the total CO2 saving [gCO2/km]

:

CO2 correction coefficient due to the positive mass difference between the efficient 48V motor generator plus 48V/12V DC-DC converter and the baseline alternator. For the data in Table 4 is to be used.

Table 4

CO2 correction coefficient due to the extra mass

Type of fuelCO2 correction coefficient due to the positive mass difference ( )[g CO2/km]
Petrol0,0277 · Δm
Diesel0,0383 · Δm

Δm (in Table 4) is the extra mass due to the installation of the 48V motor generator and the 48V/12V DC-DC converter. It is the positive difference between the mass of the 48V motor generator plus the 48V/12V DC-DC converter and the mass of baseline alternator. The mass of the baseline alternator is 7 kg. The extra mass is to be verified and confirmed in the verification report to be submitted to the type approval authority together with the application for certifications.

(1)

Commission Implementing Regulation (EU) No 427/2014 of 25 April 2014 establishing a procedure for the approval and certification of innovative technologies for reducing CO2 emissions from light commercial vehicles pursuant to Regulation (EU) No 510/2011 of the European Parliament and of the Council (OJ L 125, 26.4.2014, p. 57).

Back to top

Options/Help

Print Options

Close

Legislation is available in different versions:

Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.

Original (As adopted by EU): The original version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.

Close

See additional information alongside the content

Geographical Extent: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.

Show Timeline of Changes: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.

Close

Opening Options

Different options to open legislation in order to view more content on screen at once

Close

More Resources

Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as adopted version that was used for the EU Official Journal
  • lists of changes made by and/or affecting this legislation item
  • all formats of all associated documents
  • correction slips
  • links to related legislation and further information resources
Close

Timeline of Changes

This timeline shows the different versions taken from EUR-Lex before exit day and during the implementation period as well as any subsequent versions created after the implementation period as a result of changes made by UK legislation.

The dates for the EU versions are taken from the document dates on EUR-Lex and may not always coincide with when the changes came into force for the document.

For any versions created after the implementation period as a result of changes made by UK legislation the date will coincide with the earliest date on which the change (e.g an insertion, a repeal or a substitution) that was applied came into force. For further information see our guide to revised legislation on Understanding Legislation.

Close

More Resources

Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as adopted version that was used for the print copy
  • correction slips

Click 'View More' or select 'More Resources' tab for additional information including:

  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • links to related legislation and further information resources