Search Legislation

Commission Implementing Decision of 26 September 2014 establishing the best available techniques (BAT) conclusions, under Directive 2010/75/EU of the European Parliament and of the Council, for the production of pulp, paper and board (notified under document C(2014) 6750) (Text with EEA relevance) (2014/687/EU)

 Help about what version

What Version

 Help about advanced features

Advanced Features

Close

This is a legislation item that originated from the EU

After exit day there will be three versions of this legislation to consult for different purposes. The legislation.gov.uk version is the version that applies in the UK. The EU Version currently on EUR-lex is the version that currently applies in the EU i.e you may need this if you operate a business in the EU.

The web archive version is the official version of this legislation item as it stood on exit day before being published to legislation.gov.uk and any subsequent UK changes and effects applied. The web archive also captured associated case law and other language formats from EUR-Lex.

Changes over time for: Commission Implementing Decision of 26 September 2014 establishing the best available techniques (BAT) conclusions, under Directive 2010/75/EU of the European Parliament and of the Council, for the production of pulp, paper and board (notified under document C(2014) 6750) (Text with EEA relevance) (2014/687/EU) (Annexes only)

 Help about opening options

Status:

Point in time view as at 31/12/2020.

Changes to legislation:

There are outstanding changes not yet made to Commission Implementing Decision of 26 September 2014 establishing the best available techniques (BAT) conclusions, under Directive 2010/75/EU of the European Parliament and of the Council, for the production of pulp, paper and board (notified under document C(2014) 6750) (Text with EEA relevance) (2014/687/EU). Any changes that have already been made to the legislation appear in the content and are referenced with annotations. Help about Changes to Legislation

Close

Changes to Legislation

Changes and effects yet to be applied by the editorial team are only applicable when viewing the latest version or prospective version of legislation. They are therefore not accessible when viewing legislation as at a specific point in time. To view the ‘Changes to Legislation’ information for this provision return to the latest version view using the options provided in the ‘What Version’ box above.

ANNEXU.K.BAT CONCLUSIONS FOR THE PRODUCTION OF PULP, PAPER AND BOARD

SCOPE U.K.

These BAT conclusions concern the activities specified in Sections 6.1.(a) and 6.1.(b) of Annex I to Directive 2010/75/EU, i.e. the integrated and non-integrated production in industrial installations of:

(a)

pulp from timber or other fibrous materials;

(b)

paper or cardboard with a production capacity exceeding 20 tonnes per day.

In particular, these BAT conclusions cover the following processes and activities:

(i)

chemical pulping:

(a)

kraft (sulphate) pulping process

(b)

sulphite pulping process

(ii)

mechanical and chemimechanical pulping

(iii)

processing paper for recycling with and without deinking

(iv)

papermaking and related processes

(v)

all recovery boilers and lime kilns operated in pulp and paper mills

These BAT conclusions do not address the following activities:

(i)

production of pulp from non-wood fibrous raw material (e.g. yearly plant pulp);

(ii)

stationary internal combustion engines;

(iii)

combustion plants for steam and power generation other than recovery boilers;

(iv)

dryers with internal burners for paper machines and coaters.

Other reference documents which are relevant for the activities covered by these BAT conclusions are the following:

Reference documentsActivity
Industrial Cooling Systems (ICS)Industrial cooling systems, e.g. cooling towers, plate heat exchangers
Economics and Cross-Media Effects (ECM)Economics and cross-media effects of techniques
Emissions from Storage (EFS)Emissions from tanks, pipework and stored chemicals
Energy Efficiency (ENE)General energy efficiency
Large Combustion Plants (LCP)Generation of steam and electricity in pulp and paper mills by combustion plants
General Principles of Monitoring (MON)Emissions monitoring
Waste Incineration (WI)On-site incineration and co-incineration of waste
Waste Treatments Industries (WT)Preparation of waste as fuels

GENERAL CONSIDERATIONS U.K.

The techniques listed and described in these BAT conclusions are neither prescriptive nor exhaustive. Other techniques may be used that ensure at least an equivalent level of environmental protection.

Unless otherwise stated, the BAT conclusions are generally applicable.

EMISSION LEVELS ASSOCIATED WITH BAT U.K.

Where emission levels associated with the best available techniques (BAT-AELs) are given for the same averaging period in different units (e.g. as concentration and specific load values (that is per tonne of net production)), those different ways of expressing BAT-AELs are to be seen as equivalent alternatives.

For integrated and multi-product pulp and paper mills, the BAT-AELs defined for the individual processes (pulping, papermaking) and/or products need to be combined according to a mixing rule based on their additive shares of discharge.

AVERAGING PERIODS FOR EMISSIONS TO WATER U.K.

Unless stated otherwise, the averaging periods associated with the BAT-AELs for emissions to water are defined as follows.

a

In special cases, there may be a need to apply a different sampling procedure (e.g. grab sampling)

Daily averageAverage over a sampling period of 24 hours taken as a flow-proportional composite samplea or, provided that sufficient flow stability is demonstrated, from a time-proportional samplea
Yearly averageAverage of all daily averages taken within a year, weighted according to the daily production, and expressed as mass of emitted substances per unit of mass of products/materials generated or processed

REFERENCE CONDITIONS FOR EMISSIONS TO AIR U.K.

The BAT-AELs for emissions to air refer to standard conditions: dry gas, temperature of 273,15 K, and pressure of 101,3 kPa. Where BAT-AELs are given as concentration values, the reference O2 level ( % by volume) is indicated.

Conversion to reference oxygen concentration U.K.

The formula for calculating the emissions concentration at a reference oxygen level is shown below.

where:

ER (mg/Nm3)

:

emissions concentration referred to the reference oxygen level OR

OR (vol %)

:

reference oxygen level

EM (mg/Nm3)

:

measured emissions concentration referred to the measured oxygen level OM

OM (vol %)

:

measured oxygen level.

AVERAGING PERIODS FOR EMISSIONS TO AIR U.K.

Unless stated otherwise, the averaging periods associated with the BAT-AELs for emissions to air are defined as follows.

Daily averageAverage over a period of 24 hours based on valid hourly averages from continuous measurement
Average over the sampling periodAverage value of three consecutive measurements of at least 30 minutes each
Yearly averageIn the case of continuous measurement: average of all valid hourly averages. In the case of periodic measurements: average of all ‘averages over the sampling period’ obtained during one year.

DEFINITIONS U.K.

For the purpose of these BAT conclusions, the following definitions apply:

Term usedDefinition
New plantA plant first permitted on the site of the installation following the publication of these BAT conclusions or a complete replacement of a plant on the existing foundations of the installation following the publication of these BAT conclusions.
Existing plantA plant which is not a new plant.
Major refurbishmentA major change in design or technology of a plant/abatement system and with major adjustments or replacements of the process units and associated equipment.
New dust abatement systemA dust abatement system first operated on the site of the installation following the publication of these BAT conclusions.
Existing dust abatement systemA dust abatement system which is not a new dust abatement system.
Non-condensable odorous gases (NCG)Non-condensable odorous gases, referring to malodorous gases of kraft pulping.
Concentrated non-condensable odorous gases (CNCG)Concentrated non-condensable odorous gases (or ‘strong odorous gases’): TRS-containing gases from cooking, evaporation and from stripping of condensates.
Strong odorous gasesConcentrated non-condensable odorous gases (CNCG).
Weak odorous gasesDiluted non-condensable odorous gases: TRS-containing gases which are not strong odorous gases (e.g. gases coming from tanks, washing filters, chip bins, lime mud filters, drying machines).
Residual weak gasesWeak gases that are emitted in ways other than through a recovery boiler, a lime kiln or a TRS-burner.
Continuous measurementMeasurements using an automated measuring system (AMS) permanently installed on site.
Periodic measurementDetermination of a measurand (particular quantity subject to measurement) at specified time intervals using manual or automated methods.
Diffuse emissionsEmissions arising from a direct (non-channelled) contact of volatile substances or dust with the environment under normal operating conditions.
Integrated productionBoth pulp and paper/board are produced at the same site. The pulp is normally not dried before paper/board manufacture.
Non-integrated productionEither (a) production of market pulp (for sale) in mills that do not operate paper machines, or (b) production of paper/board using only pulp produced in other plants (market pulp).
Net production
(i)

For paper mills: the unpacked, saleable production after the last slitter winder, i.e. before converting.

(ii)

For off-line coaters: production after coating.

(iii)

For tissue mills: saleable production after the tissue machine before any rewinding processes and excluding any core.

(iv)

For market pulp mills: production after packing (ADt).

(v)

For integrated mills: Net pulp, production refers to the production after packing (ADt) plus the pulp transferred to the paper mill (pulp calculated at 90 % dryness, i.e. air dry). Net paper production: same as (i)

Speciality paper millA mill producing numerous paper and board grades for special purposes (industrial and/or non-industrial) that are characterised by particular properties, relatively small end use market or niche applications that are often especially designed for a particular customer or end-user group. Examples of speciality papers include cigarette papers, filter papers, metallised paper, thermal paper, self-copy paper, sticking labels, cast coated paper, as well as gypsum liners and special papers for waxing, insulating, roofing, asphalting, and other specific applications or treatments. All of these grades fall outside of the standard paper categories.
HardwoodGroup of wood species including e.g. aspen, beech, birch and eucalyptus. The term hardwood is used as opposite to softwood.
SoftwoodWood from conifers including e.g. pine and spruce. The term softwood is used as opposite to hardwood.
CausticisingProcess in the lime cycle in which hydroxide (white liquor) is regenerated by the reaction Ca(OH)2 + CO3 2– → CaCO3 (s) + 2 OH

ACRONYMS U.K.

Term usedDefinition
ADtAir Dry tonnes (of pulp) expressed as 90 % dryness.
AOXAdsorbable organic halides measured according to the EN ISO: 9562 standard method for waste waters.
BODBiochemical oxygen demand. The quantity of dissolved oxygen required by microorganisms to decompose organic matter in waste water.
CMPChemimechanical pulp.
CTMPChemithermomechanical pulp.
CODChemical oxygen demand; the amount of chemically oxidisable organic matter in waste water (normally referring to analysis with dichromate oxidation).
DSDry solids, expressed as weight %.
DTPADiethlyene triamine pentaacetic acid (complexing/chelating agent used in peroxide bleaching).
ECFElemental Chlorine Free.
EDTAEthylene diamine tetraacetic acid (complexing/chelating agent).
H2SHydrogen sulphide.
LWCLight weight coated paper.
NOXThe sum of nitrogen oxide (NO) and nitrogen dioxide (NO2), expressed as NO2.
NSSCNeutral sulphite semi chemical.
RCFRecycled fibres.
SO2Sulphur dioxide.
TCFTotally Chlorine Free.
Total nitrogen (Tot-N)Total nitrogen (Tot-N) given as N, includes organic nitrogen, free ammonia and ammonium (NH4 +-N), nitrites (NO2 --N) and nitrates (NO3 --N).
Total phosphorus (Tot-P)Total phosphorus (Tot-P) given as P, includes dissolved phosphorus plus any insoluble phosphorus carried over into the effluent in the form of precipitates or within microbes.
TMPThermomechanical pulp.
TOCTotal organic carbon.
TRSTotal reduced sulphur. The sum of the following reduced malodorous sulphur compounds generated in the pulping process: hydrogen sulphide, methyl mercaptan, dimethylsulphide and dimethyldisulphide, expressed as sulphur.
TSSTotal suspended solids (in waste water). Suspended solids consist of small fibre fragments, fillers, fines, non-settled biomass (agglomeration of microorganisms) and other small particles.
VOCVolatile organic compounds as defined in Article 3(45) of Directive 2010/75/EU.

1.1.GENERAL BAT CONCLUSIONS FOR THE PULP AND PAPER INDUSTRYU.K.

The process specific BAT conclusions included in Sections 1.2 to 1.6 apply, in addition to the general BAT conclusions mentioned in this section.

1.1.1. Environmental management system U.K.
BAT 1.In order to improve the overall environmental performance of plants for the production of pulp, paper and board, BAT is to implement and adhere to an environmental management system (EMS) that incorporates all of the following features:U.K.
(a)

commitment of the management, including senior management;

(b)

definition of an environmental policy that includes the continuous improvement of the installation by the management;

(c)

planning and establishing the necessary procedures, objectives and targets, in conjunction with financial planning and investment;

(d)

implementation of procedures paying particular attention to:

(i)

structure and responsibility

(ii)

training, awareness and competence

(iii)

communication

(iv)

employee involvement

(v)

documentation

(vi)

efficient process control

(vii)

maintenance programmes

(viii)

emergency preparedness and response

(ix)

safeguarding compliance with environmental legislation;

(e)

checking performance and taking corrective action, paying particular attention to:

(i)

monitoring and measurement (see also the Reference Document on the General Principles of Monitoring)

(ii)

corrective and preventive action

(iii)

maintenance of records

(iv)

independent (where practicable) internal and external auditing in order to determine whether or not the EMS conforms to planned arrangements and has been properly implemented and maintained;

(f)

review of the EMS and its continuing suitability, adequacy and effectiveness by senior management;

(g)

following the development of cleaner technologies;

(h)

consideration for the environmental impacts from the eventual decommissioning of the installation at the stage of designing a new plant, and throughout its operating life;

(i)

application of sectoral benchmarking on a regular basis.

Applicability U.K.

The scope (e.g. level of details) and nature of the EMS (e.g. standardised or non-standardised) will generally be related to the nature, scale and complexity of the installation, and the range of environmental impacts it may have.

1.1.2. Materials management and good housekeeping U.K.
BAT 2.BAT is to apply the principles of good housekeeping for minimising the environmental impact of the production process by using a combination of the techniques given below.U.K.
Technique
aCareful selection and control of chemicals and additives
bInput-output analysis with a chemical inventory, including quantities and toxicological properties
cMinimise the use of chemicals to the minimum level required by the quality specifications of the final product
dAvoid the use of harmful substances (e.g. nonylphenol ethoxylate-containing dispersion or cleaning agents or surfactants) and substitution by less harmful alternatives
eMinimise the input of substances into the soil by leakage, aerial deposition and the inappropriate storage of raw materials, products or residues
fEstablish a spill management programme and extend the containment of relevant sources, thus preventing the contamination of soil and groundwater
gProper design of the piping and storage systems to keep the surfaces clean and to reduce the need for washing and cleaning
BAT 3.In order to reduce the release of not readily biodegradable organic chelating agents such as EDTA or DTPA from peroxide bleaching, BAT is to use a combination of the techniques given below.U.K.
TechniqueApplicability
aDetermination of quantity of chelating agents released to the environment through periodic measurementsNot applicable for mills that do not use chelating agents
bProcess optimisation to reduce consumption and emission of not readily biodegradable chelating agentsNot applicable for plants that eliminate 70 % or more of EDTA/DTPA in their waste water treatment plant or process
cPreferential use of biodegradable or eliminable chelating agents, gradually phasing out non-degradable productsApplicability depends on the availability of appropriate substitutes (biodegradable agents meeting e.g. brightness requirements of pulp)
1.1.3. Water and waste water management U.K.
BAT 4.In order to reduce the generation and the pollution load of waste water from wood storage and preparation, BAT is to use a combination of the techniques given below.U.K.
TechniqueApplicability
aDry debarking (description see Section 1.7.2.1)Restricted applicability when high purity and brightness is required with TCF bleaching
bHandling of wood logs in such a way as to avoid the contamination of bark and wood with sand and stonesGenerally applicable
cPaving of the wood yard area and particularly the surfaces used for the storage of chipsApplicability may be restricted due to the size of the wood yard and storage area
dControlling the flow of sprinkling water and minimising surface run-off water from the wood yardGenerally applicable
eCollecting of contaminated run-off water from the wood yard and separating out suspended solids effluent before biological treatmentApplicability may be restricted by the degree of contamination of run-off water (low concentration) and/or the size of the waste water treatment plant (large volumes)

The BAT-associated effluent flow from dry debarking is 0,5 – 2,5 m3/ADt.

BAT 5.In order to reduce fresh water use and generation of waste water, BAT is to close the water system to the degree technically feasible in line with the pulp and paper grade manufactured by using a combination of the techniques given below.U.K.
TechniqueApplicability
aMonitoring and optimising water usageGenerally applicable
bEvaluation of water recirculation options
cBalancing the degree of closure of water circuits and potential drawbacks; adding additional equipment if necessary
dSeparation of less contaminated sealing water from pumps for vacuum generation and reuse
eSeparation of clean cooling water from contaminated process water and reuse
fReusing process water to substitute for fresh water (water recirculation and closing of water loops)

Applicable to new plants and major refurbishments.

Applicability may be limited due to water quality and/or product quality requirements or due to technical constraints (such as precipitation/incrustation in water system) or increase odour nuisance

gIn-line treatment of (parts of) process water to improve water quality to allow for recirculation or reuseGenerally applicable

The BAT-associated waste water flow at the point of discharge after waste water treatment as yearly averages are:

SectorBAT-associated waste water flow
Bleached kraft25 – 50 m3/ADt
Unbleached kraft15 – 40 m3/ADt
Bleached sulphite paper grade pulp25 – 50 m3/ADt
Magnefite pulp45 – 70 m3/ADt
Dissolving pulp40 – 60 m3/ADt
NSSC pulp11 – 20 m3/ADt
Mechanical pulp9 – 16 m3/t
CTMP and CMP9 – 16 m3/ADt
RCF paper mills without deinking1,5 – 10 m3/t (the higher end of the range is mainly associated with folding boxboard production)
RCF paper mills with deinking8 – 15 m3/t
RCF-based tissue paper mills with deinking10 – 25 m3/t
Non-integrated paper mills3,5 – 20 m3/t
1.1.4. Energy consumption and efficiency U.K.
BAT 6.In order to reduce fuel and energy consumption in pulp and paper mills, BAT is to use technique (a) and a combination of the other techniques given below.U.K.
TechniqueApplicability
a

Use an energy management system that includes all of the following features:

(i)

Assessment of the mill's overall energy consumption and production

(ii)

Locating, quantifying and optimising the potentials for energy recovery

(iii)

Monitoring and safeguarding the optimised situation for energy consumption

Generally applicable
bRecover energy by incinerating those wastes and residues from the production of pulp and paper that have high organic content and calorific value, taking into account BAT 12Only applicable if the recycling or reuse of wastes and residues from the production of pulp and paper with a high organic content and high calorific value is not possible
cCover the steam and power demand of the production processes as far as possible by the cogeneration of heat and power (CHP)Applicable for all new plants and for major refurbishments of the energy plant. Applicability in existing plants may be limited due to the mill layout and available space
dUse excess heat for the drying of biomass and sludge, to heat boiler feedwater and process water, to heat buildings, etc.Applicability of this technique may be limited in cases where the heat sources and locations are far apart
eUse thermo compressorsApplicable to both new and existing plants for all grades of paper and for coating machines, as long as medium pressure steam is available
fInsulate steam and condensate pipe fittingsGenerally applicable
gUse energy efficient vacuum systems for dewatering
hUse high efficiency electrical motors, pumps and agitators
iUse frequency inverters for fans, compressors and pumps
jMatch steam pressure levels with actual pressure needs
Description U.K.

Technique (c): Simultaneous generation of heat and electrical and/or mechanical energy in a single process, referred to as a combined heat and power plant (CHP). CHP plants in the pulp and paper industry normally apply steam turbines and/or gas turbines. The economic viability (achievable savings and payback time) will depend mainly on the cost of electricity and fuels.

1.1.5. Emissions of odour U.K.

With regard to the emissions of malodorous sulphur-containing gases from kraft and sulphite pulp mills, see the process-specific BAT given in Sections 1.2.2 and 1.3.2.

BAT 7.In order to prevent and reduce the emission of odorous compounds originating from the waste water system, BAT is to use a combination of the techniques given below.U.K.
Technique
I. Applicable for odours related to water systems closure
aDesign paper mill processes, stock and water storage tanks, pipes and chests in such a way as to avoid prolonged retention times, dead zones or areas with poor mixing in water circuits and related units, in order to avoid uncontrolled deposits and the decay and decomposition of organic and biological matter.
bUse biocides, dispersants or of oxidising agents (e.g. catalytic disinfection with hydrogen peroxide) to control odour and decaying bacteria growth.
cInstall internal treatment processes (‘kidneys’) to reduce the concentrations of organic matter and consequently possible odour problems in the white water system.
II. Applicable for odours related to waste water treatment and sludge handling, in order to avoid conditions where waste water or sludge becomes anaerobic
aImplement closed sewer systems with controlled vents, using chemicals in some cases to reduce the formation of and to oxidise hydrogen sulphide in sewer systems.
bAvoid over-aeration in equalisation basins but maintain sufficient mixing.
cEnsure sufficient aeration capacity and mixing properties in aeration tanks; revise the aeration system regularly.
dGuarantee proper operation of secondary clarifier sludge collection and return sludge pumping
eLimit the retention time of sludge in sludge storages by sending the sludge continuously to the dewatering units.
fAvoid the storage of waste water in the spill basin longer than is necessary; keep the spill basin empty.
gIf sludge dryers are used, treatment of thermal sludge dryer vent gases by scrubbing and/or bio filtration (such as compost filters).
hAvoid air cooling towers for untreated water effluent by applying plate heat exchangers.
1.1.6. Monitoring of key process parameters and of emissions to water and air U.K.
BAT 8.BAT is to monitor the key process parameters according to the table given below.U.K.
I. Monitoring key process parameters relevant for emissions to air
ParameterMonitoring frequency
Pressure, temperature, oxygen, CO and water vapour content in flue-gas for combustion processesContinuous
II. Monitoring key process parameters relevant for emissions to water
ParameterMonitoring frequency
Water flow, temperature and pHContinuous
P and N content in biomass, sludge volume index, excess ammonia and ortho-phosphate in the effluent, and microscopy checks of the biomassPeriodic
Volume flow and CH4 content of biogas produced in anaerobic waste water treatmentContinuous
H2S and CO2 contents of biogas produced in anaerobic waste water treatmentPeriodic
BAT 9.BAT is to carry out the monitoring and measurement of emissions to air, as indicated below, on a regular basis with the frequency indicated and according to EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards which ensure the provision of data of an equivalent scientific quality.U.K.
ParameterMonitoring frequencyEmission sourceMonitoring associated with
aNOx and SO2ContinuousRecovery boiler

BAT 21

BAT 22

BAT 36

BAT 37

Periodic or continuousLime kiln

BAT 24

BAT 26

Periodic or continuousDedicated TRS burner

BAT 28

BAT 29

bDustPeriodic or continuousRecovery boiler (kraft) and lime kiln

BAT 23

BAT 27

PeriodicRecovery boiler (sulphite)BAT 37
cTRS (including H2S)ContinuousRecovery boilerBAT 21
Periodic or continuousLime kiln and dedicated TRS burner

BAT 24

BAT 25

BAT 28

PeriodicDiffuse emissions from different sources (e.g. the fibre line, tanks, chip bins, etc.) and residual weak gases

BAT 11

BAT 20

dNH3PeriodicRecovery boiler equipped with SNCRBAT 36
BAT 10.BAT is to carry out the monitoring of emissions to water, as indicated below, with the indicated frequency and according to EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality.U.K.
a

There is a trend to replace COD by TOC for economic and environmental reasons. If TOC is already measured as a key process parameter, there is no need to measure COD; however, a correlation between the two parameters should be established for the specific emission source and waste water treatment step.

b

Rapid test methods can also be used. The results of rapid tests should be checked regularly (e.g. monthly) against EN standards or, if EN standards are not available, against ISO, national or other international standards which ensure the provision of data of an equivalent scientific quality.

c

For mills operating less than seven days a week, the monitoring frequency for COD and TSS may be reduced to cover the days the mill is in operation or to extend the sampling period to 48 or 72 hours.

d

Applicable where EDTA or DTPA (chelating agents) are used in the process.

e

Not applicable to plants that provide evidence that no AOX is generated or added via chemical additives and raw materials.

ParameterMonitoring frequencyMonitoring associated with
a

Chemical oxygen demand (COD) or

Total organic carbon (TOC)a

Dailyb c

BAT 19

BAT 33

BAT 40

BAT 45

BAT 50

bBOD5 or BOD7Weekly (once a week)
cTotal suspended solids (TSS)Dailyb c
dTotal nitrogenWeekly (once a week)b
eTotal phosphorusWeekly (once a week)b
fEDTA, DTPAdMonthly (once a month)
gAOX (according to EN ISO 9562:2004)eMonthly (once a month)BAT 19: bleached kraft
Once every two months

BAT 33: except TCF and NSSC mills

BAT 40: except CTMP and CMP mills

BAT 45

BAT 50

hRelevant metals (e.g. Zn, Cu, Cd, Pb, Ni)Once a year
BAT 11.BAT is to regularly monitor and assess diffuse total reduced sulphur emissions from relevant sources.U.K.
Description U.K.

The assessment of diffuse total reduced sulphur emissions can be done by periodic measurement and assessment of diffuse emissions that are emitted from different sources (e.g. the fibre line, tanks, chip bins etc.) by direct measurements.

1.1.7. Waste management U.K.
BAT 12.In order to reduce the quantities of wastes sent for disposal, BAT is to implement a waste assessment (including waste inventories) and management system, so as to facilitate waste reuse, or failing that, waste recycling, or failing that, ‘other recovery’, including a combination of the techniques given below.U.K.
TechniqueDescriptionApplicability
aSeparate collection of different waste fractions (including separation and classification of hazardous waste)See Section 1.7.3Generally applicable
bMerging of suitable fractions of residues to obtain mixtures that can be better utilisedGenerally applicable
cPretreatment of process residues before reuse or recyclingGenerally applicable
dMaterial recovery and recycling of process residues on siteGenerally applicable
eEnergy recovery on- or off-site from wastes with high organic contentFor off-site utilisation, the applicability depends on the availability of a third party
fExternal material utilisationDepending on the availability of a third party
gPretreatment of waste before disposalGenerally applicable
1.1.8. Emissions to water U.K.

Further information on waste water treatment in pulp and paper mills and process-specific BAT-AELs are given in Sections 1.2 to 1.6.

BAT 13.In order to reduce nutrient (nitrogen and phosphorus) emissions into receiving waters, BAT is to substitute chemical additives with high nitrogen and phosphorus contents by additives containing low nitrogen and phosphorus contents.U.K.
Applicability U.K.

Applicable if the nitrogen in the chemical additives is not bioavailable (i.e. it cannot serve as nutrient in biological treatment) or if the nutrient balance is in surplus.

BAT 14.In order to reduce emissions of pollutants into receiving waters, BAT is to use all of the techniques given below.U.K.
a

Not applicable to plants where the biological load of waste water after the primary treatment is very low, e.g. some paper mills producing speciality paper.

TechniqueDescription
aPrimary (physico-chemical) treatmentSee Section 1.7.2.2
bSecondary (biological) treatmenta
BAT 15.When further removal of organic substances, nitrogen or phosphorus is needed, BAT is to use tertiary treatment as described in Section 1.7.2.2.U.K.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

BAT 16.In order to reduce emissions of pollutants into receiving waters from biological waste water treatment plants, BAT is to use all of the techniques given below.U.K.
Technique
aProper design and operation of the biological treatment plant
bRegularly controlling the active biomass
cAdjustment of nutrition supply (nitrogen and phosphorus) to the actual need of the active biomass
1.1.9. Emissions of noise U.K.
BAT 17.In order to reduce the emissions of noise from pulp and paper manufacturing, BAT is to use a combination of the techniques given below.U.K.
TechniqueDescriptionApplicability
aNoise-reduction programmeA noise-reduction programme includes identification of sources and affected areas, calculations and measurements of noise levels in order to rank sources according to noise levels, and identification of the most cost effective combination of techniques, their implementation and monitoring.Generally applicable.
bStrategic planning of the location of equipment, units and buildingsNoise levels can be reduced by increasing the distance between the emitter and the receiver and by using buildings as noise screens.Generally applicable to new plants. In the case of existing plants, the relocation of equipment and production units may be restricted by the lack of space or by excessive costs.
cOperational and management techniques in buildings containing noisy equipment

This includes:

  • improved inspection and maintenance of equipment to prevent failures

  • closing of doors and windows of covered areas

  • equipment operation by experienced staff

  • avoidance of noisy activities during night-time

  • provisions for noise control during maintenance activities

Generally applicable.
dEnclosing noisy equipment and unitsEnclosure of noisy equipment, such as wood handling, hydraulic units, and compressors in separate structures, such as buildings or soundproofed cabinets, where internal-external lining is made of impact-absorbent material.
eUse of low-noise equipment and noise-reducers on equipment and ducts.
fVibration insulationVibration insulation of machinery and decoupled arrangement of noise sources and potentially resonant components.
gSoundproofing of buildings

This potentially includes use of:

  • sound-absorbing materials in walls and ceilings

  • sound-isolating doors

  • double-glazed windows

hNoise abatementNoise propagation can be reduced by inserting barriers between emitters and receivers. Appropriate barriers include protection walls, embankments and buildings. Suitable noise abatement techniques include fitting silencers and attenuators to noisy equipment such as steam releases and dryer vents.Generally applicable to new plants. In the case of existing plants, the insertion of obstacles may be restricted by the lack of space.
iUse of larger wood-handling machines to reduce lifting and transport times and noise from logs falling onto log piles or the feed table.Generally applicable.
jImproved ways of working, e.g. releasing logs from a lower height onto the log piles or the feed table; immediate feedback of the level of noise for the workers.
1.1.10. Decommissioning U.K.
BAT 18.In order to prevent pollution risks when decommissioning a plant, BAT is to use the general techniques given below.U.K.
Technique
aEnsure that underground tanks and piping are either avoided in the design phase or that their location is well known and documented.
bEstablish instructions for emptying process equipment, vessels and piping.
cEnsure a clean closure when the facility is shut down, e.g. to clean up and rehabilitate the site. Natural soil functions should be safeguarded, if feasible.
dUse a monitoring programme, especially relative to groundwater, in order to detect possible future impacts on site or in neighbouring areas.
eDevelop and maintain a site closure or cessation scheme, based on risk analysis, that includes a transparent organisation of the shutdown work, taking into account relevant local specific conditions.

1.2.BAT CONCLUSIONS FOR KRAFT PULPING PROCESSU.K.

For integrated kraft pulp and paper mills, the process-specific BAT conclusions for papermaking given in Section 1.6 apply, in addition to the BAT conclusions in this section.

1.2.1. Waste water and emissions to water U.K.
BAT 19.In order to reduce emissions of pollutants into receiving waters from the whole mill, BAT is to use TCF or modern ECF bleaching (see description in Section 1.7.2.1), and a suitable combination of the techniques specified in BAT 13, BAT 14, BAT 15 and BAT 16 and of the techniques given below.U.K.
TechniqueDescriptionApplicability
aModified cooking before bleachingSee Section 1.7.2.1Generally applicable
bOxygen delignification before bleaching
cClosed brown stock screening and efficient brown stock washing
dPartial process water recycling in the bleach plantWater recycling may be limited due to incrustation in bleaching
eEffective spill monitoring and containment with a suitable recovery systemGenerally applicable
fMaintaining sufficient black liquor evaporation and recovery boiler capacity to cope with peak loadsGenerally applicable
gStripping the contaminated (foul) condensates and reusing the condensates in the process
BAT-associated emission levels U.K.

See Table 1 and Table 2. These BAT-associated emission levels are not applicable to dissolving kraft pulp mills.

The reference waste water flow for kraft mills is set out in BAT 5.

Table 1

BAT-associated emission levels for the direct waste water discharge to receiving waters from a bleached kraft pulp mill

a

The BAT-AEL ranges refer to market pulp production and the pulp production part of integrated mills (emissions from papermaking are not included).

b

A compact biological waste water treatment plant can result in slightly higher emission levels.

c

The upper end of the range refers to mills using eucalyptus from regions with higher levels of phosphorus (e.g. Iberian eucalyptus).

d

Applicable for mills using chlorine containing bleaching chemicals.

e

For mills producing pulp with high strength, stiffness and high purity properties (e.g. for liquid packaging board and LWC), emissions level of AOX up to 0,25 kg/ADt may occur.

ParameterYearly averagekg/ADta
Chemical oxygen demand (COD)7 – 20
Total suspended solids (TSS)0,3 – 1,5
Total nitrogen0,05 – 0,25b
Total phosphorus

0,01 – 0,03b

Eucalyptus: 0,02 – 0,11 kg/ADtc

Adsorbable organically bound halogens (AOX)d e0 – 0,2
Table 2

BAT-associated emission levels for the direct waste water discharge to receiving waters from an unbleached kraft pulp mill

a

The BAT-AEL ranges refer to market pulp production and the pulp production part of integrated mills (emissions from papermaking are not included).

b

A compact biological waste water treatment plant can result in slightly higher emission levels.

ParameterYearly averagekg/ADta
Chemical oxygen demand (COD)2,5 – 8
Total suspended solids (TSS)0,3 – 1,0
Total nitrogen0,1 – 0,2b
Total phosphorus0,01 – 0,02b

The BOD concentration in the treated effluents is expected to be low (around 25 mg/l as a 24-hour composite sample).

1.2.2. Emissions to air U.K.
1.2.2.1. Reduction of emissions in strong and weak odorous gases U.K.
BAT 20.In order to reduce odour emissions and total reduced sulphur emissions due to strong and weak odorous gases, BAT is to prevent diffuse emissions by capturing all process-based sulphur containing off-gases, including all vents with sulphur-containing emissions, by applying all of the techniques given below.U.K.
a

The SOx emission levels of the lime kiln increase significantly when strong non-condensable gases (NCG) are fed to the kiln and no alkaline scrubber is used.

b

Applicable for the treatment of weak odorous gases.

c

Applicable for the treatment of strong odorous gases.

TechniqueDescription
a

Collection systems for strong and weak odorous gases, comprising the following features:

  • covers, suction hoods, ducts, and extraction system with sufficient capacity;

  • continuous leak detection system;

  • safety measures and equipment.

bIncineration of strong and weak non-condensable gases

Incineration can be carried out using:

  • recovery boiler

  • lime kilna

  • dedicated TRS burner equipped with wet scrubbers for SOx removal; or

  • power boilerb

To ensure the constant availability of incineration for odorous strong gases, back-up systems are installed. Lime kilns can serve as back-up for recovery boilers; further back-up equipment are flares and package boiler

cRecording unavailability of the incineration system and any resulting emissionsc
Applicability U.K.

Generally applicable for new plants and for major refurbishments of existing plants. The installation of necessary equipment may be difficult for existing plants due to layout and space restrictions. The applicability of incineration might be limited for safety reasons, and in this case wet scrubbers could be used.

BAT-associated emission level of total reduced sulphur (TRS) in residual weak gases emitted is 0,05 – 0,2 kg S/ADt.

1.2.2.2. Reduction of emissions from a recovery boiler U.K.
SO2 and TRS emissionsU.K.
BAT 21.In order to reduce SO2 and TRS emissions from a recovery boiler, BAT is to use a combination of the techniques given below.U.K.
TechniqueDescription
aIncreasing the dry solids (DS) content of black liquorThe black liquor can be concentrated by an evaporation process before burning
bOptimised firingFiring conditions can be improved e.g. by good mixing of air and fuel, control of furnace load etc.
cWet scrubberSee Section 1.7.1.3
BAT-associated emission levels U.K.

See Table 3.

Table 3

BAT-associated emission levels for SO2 and TRS emissions from a recovery boiler

a

Increasing the DS content of the black liquor results in lower SO2 emissions and higher NOx emissions. Due to this, a recovery boiler with low emission levels for SO2, may be on the higher end of the range for NOx and vice versa.

b

BAT-AELs do not cover periods during which the recovery boiler is run on a DS content much lower than the normal DS content due to shut down or maintenance of the black liquor concentration plant.

c

If a recovery boiler were to burn black liquor with a DS > 83 %, then SO2 and gaseous S emission levels should be reconsidered on a case-by-case basis.

d

The range is applicable without the incineration of odorous strong gases.

DS = dry solid content of the black liquor.

ParameterDaily averagea bmg/Nm3 at 6 % O2Yearly averageamg/Nm3 at 6 % O2Yearly averageakg S/ADt
SO2DS < 75 %10 – 705 – 50
DS 75 – 83 %c10 – 505 – 25
Total reduced sulphur (TRS)1 – 10d1 – 5
Gaseous S (TRS-S + SO2-S)DS < 75 %0,03 – 0,17
DS 75 – 83 %c0,03 – 0,13
NOx emissionsU.K.
BAT 22.In order to reduce NOx emissions from a recovery boiler, BAT is to use an optimised firing system including all of the features given below.U.K.
Technique
aComputerised combustion control
bGood mixing of fuel and air
cStaged air feed systems, e.g. by using different air registers and air inlet ports
Applicability U.K.

Technique (c)is applicable to new recovery boilers and in the case of a major refurbishment of recovery boilers, as this technique requires considerable changes to the air feed systems and the furnace.

BAT-associated emission levels U.K.

See Table 4.

Table 4

BAT-associated emission levels for NOx emissions from a recovery boiler

a

Increasing the DS content of the black liquor results in lower SO2 emissions and higher NOx emissions. Due to this, a recovery boiler with low emission levels for SO2, may be on the higher end of the range for NOx and vice versa.

b

The actual NOx emission level of a recovery boiler depends on the DS content and the nitrogen content of the black liquor, and the amount and combination of NCG and other nitrogen containing flows (e.g. dissolving tank vent gas, methanol separated from the condensate, biosludge) burnt. The higher the DS content, the nitrogen content in the black liquor, and the amount of NCG and other nitrogen containing flows burnt, the closer the emissions will be to the upper end of the BAT-AEL range.

c

If a recovery boiler were to burn black liquor with a DS > 83 %, then NOx emission levels should be reconsidered on a case-by-case basis.

DS = dry solid content of black liquor.

ParameterYearly averageamg/Nm3 at 6 % O2Yearly averageakg NOx/ADt
NOxSoftwood120 – 200b

DS < 75 %: 0,8 – 1,4

DS 75 – 83 %c: 1,0 – 1,6

Hardwood120 – 200b

DS < 75 %: 0,8 – 1,4

DS 75 – 83 %c: 1,0 – 1,7

Dust emissionsU.K.
BAT 23.In order to reduce dust emissions from a recovery boiler, BAT is to use an electrostatic precipitator (ESP) or a combination of ESP and wet scrubber.U.K.
Description U.K.

SeeSection 1.7.1.1.

BAT-associated emission levels U.K.

See Table 5.

Table 5

BAT-associated emission levels for dust emissions from a recovery boiler

a

For an existing recovery boiler equipped with an ESP approaching the end of its operational life, emission levels may increase over time up to 50 mg/Nm3 (corresponding to 0,4 kg/ADt).

ParameterDust abatement systemYearly averagemg/Nm3 at 6 % O2Yearly averagekg dust/ADt
DustNew or major refurbishment10 – 250,02 – 0,20
Existing10 – 40a0,02 — 0,3a
1.2.2.3. Reduction of emissions from a lime kiln U.K.
SO2 emissionsU.K.
BAT 24.In order to reduce SO2 emissions from a lime kiln, BAT is to apply one or a combination of the techniques given below.U.K.
TechniqueDescription
aFuel selection/low sulphur fuelSee Section 1.7.1.3
bLimit incineration of sulphur-containing odorous strong gases in the lime kiln
cControl of Na2S content in lime mud feed
dAlkaline scrubber
BAT-associated emission levels U.K.

See Table 6.

Table 6

BAT-associated emission levels for SO2 and sulphur emissions from a lime kiln

a

‘strong gases’ includes methanol and turpentine

ParameteraYearly averagemg SO2/Nm3 at 6 % O2Yearly averagekg S/ADt
SO2 when strong gases are not burnt in the lime kiln5 – 70
SO2 when strong gases are burnt in the lime kiln55 – 120
Gaseous S (TRS-S + SO2-S) when strong gases are not burnt in the lime kiln0,005 – 0,07
Gaseous S (TRS-S + SO2-S) when strong gases are burnt in the lime kiln0,055 – 0,12
TRS emissionsU.K.
BAT 25.In order to reduce TRS emissions from a lime kiln, BAT is to apply one or a combination of the techniques given below.U.K.
TechniqueDescription
aControl of the excess oxygenSee Section 1.7.1.3
bControl of Na2S content in lime mud feed
cCombination of ESP and alkaline scrubberSee Section 1.7.1.1
BAT-associated emission levels U.K.

See Table 7.

Table 7

BAT-associated emission levels for TRS emissions from a lime kiln

a

For lime kilns burning strong gases (including methanol and turpentine), the upper end of the AEL range may be up to 40 mg/Nm3.

ParameterYearly averagemg S/Nm3 at 6 % O2
Total reduced sulphur (TRS)< 1 – 10a
NOx emissionsU.K.
BAT 26.In order to reduce NOx emissions from a lime kiln, BAT is to apply a combination of the techniques given below.U.K.
TechniqueDescription
aOptimised combustion and combustion controlSee Section 1.7.1.2
bGood mixing of fuel and air
cLow-NOx burner
dFuel selection/low-N fuel
BAT-associated emission levels U.K.

See Table 8.

Table 8

BAT-associated emission levels for NOx emissions from a lime kiln

a

When using liquid fuels originating from vegetable matter (e.g. turpentine, methanol, tall-oil), including those obtained as by-products of the pulping process, emission levels up to 350 mg/Nm3 (corresponding to 0,35 kg NOx/ADt) may occur.

b

When using gaseous fuels originating from vegetable matter (e.g. non-condensable gases), including those obtained as by-products of the pulping process, emission levels up to 450 mg/Nm3 (corresponding to 0,45 kg NOx/ADt) may occur.

ParameterYearly averagemg/Nm3 at 6 % O2Yearly averagekg NOx/ADt
NOxLiquid fuels100 – 200a0,1 – 0,2a
Gaseous fuels100 – 350b0,1 – 0,3b
Dust emissionsU.K.
BAT 27.In order to reduce dust emissions from a lime kiln, BAT is to use an electrostatic precipitator (ESP) or a combination of ESP and wet scrubber.U.K.
Description U.K.

See Section 1.7.1.1.

BAT-associated emission levels U.K.

See Table 9.

Table 9

BAT-associated emission levels for dust emissions from a lime kiln

a

For an existing lime kiln equipped with an ESP approaching the end of its operational life, emission levels may increase over time up to 50 mg/Nm3 (corresponding to 0,05 kg/ADt).

ParameterDust abatement systemYearly averagemg/Nm3 at 6 % O2Yearly averagekg dust/ADt
DustNew or major refurbishments10 – 250,005 – 0,02
Existing10 – 30a0,005 – 0,03a
1.2.2.4. Reduction of emissions from a burner for strong odorous gases (dedicated TRS burner) U.K.
BAT 28.In order to reduce SO2 emissions from the incineration of strong odorous gases in a dedicated TRS burner, BAT is to use an alkaline SO2 scrubber.U.K.
BAT-associated emission levels U.K.

See Table 10.

Table 10

BAT-associated emission levels for SO2 and TRS emissions from the incineration of strong gases in a dedicated TRS burner

a

This BAT-AEL is based on a gas flow in the range of 100-200 Nm3/ADt.

ParameterYearly averagemg/Nm3 at 9 % O2Yearly averagekg S/ADt
SO220 – 120
TRS1 – 5
Gaseous S (TRS-S + SO2-S)0,002 – 0,05a
BAT 29.In order to reduce NOx emissions from the incineration of strong odorous gases in a dedicated TRS burner, BAT is to use one or a combination of the techniques given below.U.K.
TechniqueDescriptionApplicability
aBurner/firing optimisationSee Section 1.7.1.2Generally applicable
bStaged incinerationSee Section 1.7.1.2Generally applicable for new plants and for major refurbishments. For existing mills, applicable only if space allows for the insertion of equipment
BAT-associated emission levels U.K.

See Table 11.

Table 11

BAT-associated emission levels for NOx emissions from the incineration of strong gases in a dedicated TRS burner

a

Where at existing plants a switch to staged incineration is not feasible, emissions levels up to 1 000 mg/Nm3 (corresponding to 0,2 kg/ADt) may occur.

ParameterYearly averagemg/Nm3 at 9 % O2Yearly averagekg NOx/ADt
NOx50 – 400a0,01 – 0,1a
1.2.3. Waste generation U.K.
BAT 30.In order to prevent waste generation and minimise the amount of solid waste to be disposed of, BAT is to recycle dust from black liquor recovery boiler ESPs to the process.U.K.
Applicability U.K.

Recirculation of dust may be limited due to non-process elements in the dust.

1.2.4. Energy consumption and efficiency U.K.
BAT 31.In order to reduce thermal energy consumption (steam), maximise the benefit of energy carriers used, and to reduce the consumption of electricity, BAT is to apply a combination of the techniques given below.U.K.
Technique
aHigh dry solid content of bark, by use of efficient presses or drying
bHigh efficiency steam boilers, e.g. low flue-gas temperatures
cEffective secondary heating systems
dClosing water systems, including bleach plant
eHigh pulp concentration (middle or high consistency technique)
fHigh efficiency evaporation plant
gRecovery of heat from dissolving tanks e.g. by vent scrubbers
hRecovery and use of the low temperature streams from effluents and other waste heat sources to heat buildings, boiler feedwater and process water
iAppropriate use of secondary heat and secondary condensate
jMonitoring and control of processes, using advanced control systems
kOptimise integrated heat exchanger network
lHeat recovery from the flue-gas from the recovery boiler between the ESP and the fan
mEnsuring as high a pulp consistency as possible in screening and cleaning
nUse of speed control of various large motors
oUse of efficient vacuum pumps
pProper sizing of pipes, pumps and fans
qOptimised tank levels
BAT 32.In order to increase the efficiency of power generation, BAT is to apply a combination of the techniques given below.U.K.
Technique
aHigh black liquor dry solid content (increases boiler efficiency, steam generation and thus electricity generation)
bHigh recovery boiler pressure and temperature; in new recovery boilers the pressure can be at least 100 bars and the temperature 510 °C
cOutlet steam pressure in the back-pressure turbine as low as technically feasible
dCondensing turbine for power production from excess steam
eHigh turbine efficiency
fPreheating feedwater to a temperature close to the boiling temperature
gPreheating the combustion air and fuel charged to the boilers

1.3.BAT CONCLUSIONS FOR THE SULPHITE PULPING PROCESSU.K.

For integrated sulphite pulp and paper mills, the process-specific BAT conclusions for papermaking given in Section 1.6 apply, in addition to the BAT in this section.

1.3.1. Waste water and emissions to water U.K.
BAT 33.In order to prevent and reduce emissions of pollutants into receiving waters from the whole mill, BAT is to use a suitable combination of the techniques specified in BAT 13, BAT 14, BAT 15 and BAT 16 and of the techniques given below.U.K.
TechniqueDescriptionApplicability
aExtended modified cooking before bleaching.See Section 1.7.2.1Applicability may be limited due to pulp quality requirements (when high strength is required).
bOxygen delignification before bleaching.
cClosed brown stock screening and efficient brown stock washing.Generally applicable.
dEvaporation of effluents from the hot alkaline extraction stage and incineration of concentrates in a soda boiler.Limited applicability for dissolving pulp mills, when multistage biological treatment of the effluents provides a more favourable overall environmental situation.
eTCF bleaching.Limited applicability for market paper pulp mills producing high brightness pulp and for mills manufacturing speciality pulp for chemical applications.
fClosed-loop bleaching.Only applicable to plants that use the same base for cooking and pH adjustment in bleaching.
gMgO-based pre-bleaching and recirculation of washing liquids from pre-bleaching to brown stock washing.Applicability may be limited by factors such as product quality (e.g. purity, cleanliness and brightness), kappa number after cooking, hydraulic capacity of the installation and capacity of tanks, evaporators and recovery boilers, and a possibility to clean the washing equipment.
hpH adjustment of weak liquor before/inside the evaporation plant.Generally applicable to magnesium-based plants. Spare capacity in the recovery boiler and ash circuit is needed.
iAnaerobic treatment of the condensates from the evaporators.Generally applicable.
jStripping and recovery of SO2 from the condensates of evaporators.Applicable if it is necessary to protect anaerobic effluent treatment.
kEffective spill monitoring and containment, also with chemical and energy recovery system.Generally applicable.
BAT-associated emission levels U.K.

See Table 12 and Table 13. These BAT-associated emission levels are not applicable to dissolving pulp mills and to the manufacturing of speciality pulp for chemical applications.

The reference waste water flow for sulphite mills is set out in BAT 5.

Table 12

BAT-associated emission levels for the direct waste water discharge to receiving waters from a pulp mill manufacturing bleached sulphite and magnefite paper grade pulp

a

The BAT-AEL ranges refer to market pulp production and the pulp production part of integrated mills (emissions from papermaking are not included).

b

The BAT-AELs do not apply to natural greaseproof pulp mills).

c

The BAT-AEL for COD and total phosphorus do not apply to eucalyptus based market pulp

d

Sulphite market pulp mills may apply a gentle ClO2 bleaching stage in order to meet product requirements, thus resulting in AOX emissions.

e

Not applicable to TCF mills

ParameterBleached sulphite paper grade pulpaMagnefite paper grade pulpa
Yearly averagekg/ADtbYearly averagekg/ADt
Chemical oxygen demand (COD)10 – 30c20 – 35
Total suspended solids (TSS)0,4 – 1,50,5 – 2,0
Total nitrogen0,15 – 0,30,1 – 0,25
Total phosphorus0,01 – 0,05c0,01 – 0,07
Yearly averagemg/l
Adsorbable organically bound halogens (AOX)0,5 – 1,5d e
Table 13

BAT-associated emission levels for the direct waste water discharge to receiving waters from a sulphite pulp mill manufacturing NSSC pulp

a

The BAT-AEL ranges refer to market pulp production and the pulp production part of integrated mills (emissions from papermaking are not included).

b

Due to process-specific higher emissions, the BAT-AEL for total nitrogen does not apply to ammonium-based NSSC pulping.

ParameterYearly averagekg/ADta
Chemical oxygen demand (COD)3,2 – 11
Total suspended solids (TSS)0,5 – 1,3
Total nitrogen0,1 – 0,2b
Total phosphorus0,01 – 0,02

The BOD concentration in the treated effluents is expected to be low (around 25 mg/l as a 24-hour composite sample).

1.3.2. Emissions to air U.K.
BAT 34.In order to prevent and reduce SO2 emissions, BAT is to collect all highly concentrated SO2-gas streams from acid liquor production, digesters, diffusers, or blow tanks and to recover the sulphur components.U.K.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

BAT 35.In order to prevent and reduce diffuse sulphur-containing and odorous emissions from washing, screening, and evaporators, BAT is to collect these weak gases and to apply one of the techniques given below.U.K.
TechniqueDescriptionApplicability
aIncineration in a recovery boilerSee Section 1.7.1.3Not applicable to sulphite pulp mills using calcium-based cooking. These mills do not operate a recovery boiler
bWet scrubberSee Section 1.7.1.3Generally applicable
BAT 36.In order to reduce NOx emissions from a recovery boiler, BAT is to use an optimised firing system including one or a combination of the techniques given below.U.K.
TechniqueDescriptionApplicability
aOptimising the recovery boiler by controlling the firing conditionsSee Section 1.7.1.2Generally applicable
bStaged injection of spent liquorApplicable to new large recovery boilers and major recovery boilers refurbishments
cSelective non-catalytic reduction (SNCR)Retrofitting of existing recovery boilers may be limited due to scaling problems and associated increased cleaning and maintenance requirements. For ammonium-based mills, no application was reported; but due to specific conditions in the waste gas, SNCR is expected to be without effect. Not applicable to sodium-based mills due to explosion risk
BAT-associated emission levels U.K.

See Table 14.

Table 14

BAT-associated emission levels for NOx and NH3 emissions from a recovery boiler

a

For ammonium-based mills, higher emission levels of NOx may occur: up to 580 mg/Nm3 as daily average and up to 450 mg/Nm3 as yearly average.

ParameterDaily averagemg/Nm3 at 5 % O2Yearly averagemg/Nm3 at 5 % O2
NOx100 – 350a100 – 270a
NH3 (ammonia slip for SNCR)< 5
BAT 37.In order to reduce dust and SO2 emissions from a recovery boiler, BAT is to use one of the techniques given below and to limit ‘acid operation’ of the scrubbers to the minimum required to ensure their proper functioning.U.K.
TechniqueDescription
aESP or multicyclones with multistage venturi scrubbersSee Section 1.7.1.3
bESP or multicyclones with multistage double inlet downstream scrubbers
BAT-associated emission levels U.K.

See Table 15.

Table 15

BAT-associated emission levels for dust and SO2 emissions from a recovery boiler

a

For recovery boilers operated in mills using more than 25 % of hardwood (potassium-rich) in raw materials, higher dust emissions up to 30 mg/Nm3 may occur.

b

The BAT-AEL for dust does not apply for ammonium-based mills.

c

Due to process-specific higher emissions, the BAT-AEL for SO2 does not apply for recovery boilers operated permanently under ‘acidic’ conditions, i.e. using sulphite liquor as wet-scrubber washing media as part of the sulphite recovery process.

d

For existing multistage venturi scrubbers, higher emissions of SO2 up to 400 mg/Nm3 as a daily average value and up to 350 mg/Nm3 as a yearly average may occur.

e

Not applicable during ‘acid operation’, i.e. periods in which preventive flushing and cleaning of incrustation in the scrubbers takes place. During these periods emissions can be up to 300 – 500 mg SO2/Nm3 (at 5 % O2) for cleaning of one of the scrubbers and up to 1 200 mg SO2/Nm3 (half-hourly mean values, at 5 % O2) when cleaning the final washer.

ParameterAverage over the sampling periodmg/Nm3 at 5 % O2
Dust5 – 20a b

Daily average

mg/Nm3 at 5 % O2

Yearly average

mg/Nm3 at 5 % O2

SO2100 – 300c d e50 – 250c d

The BAT-associated environmental performance level is a duration of acid operation of around 240 hours per year for the scrubbers, and less than 24 hours per month for the last monosulphite scrubber.

1.3.3. Energy consumption and efficiency U.K.
BAT 38.In order to reduce thermal energy consumption (steam), maximise the benefit of the energy carriers used and to reduce the consumption of electricity, BAT is to use a combination of the techniques given below.U.K.
Technique
aHigh dry solids content of bark, by use of efficient presses or drying
bHigh efficiency steam boilers, e.g. low exhaust-gas temperatures
cEffective secondary heating system
dClosing water systems, including bleach plant
eHigh pulp concentration (middle or high consistency techniques)
fRecovery and use of the low temperature streams from effluents and other waste heat sources to heat buildings, boiler feedwater and process water
gAppropriate use of secondary heat and secondary condensate
hMonitoring and control of processes, using advanced control systems
iOptimise integrated heat exchanger network
jEnsuring as high pulp consistency as possible in screening and cleaning
kOptimised tank levels
BAT 39.In order to increase the efficiency of power generation, BAT is to use a combination of the techniques given below.U.K.
Technique
aHigh recovery boiler pressure and temperature
bOutlet steam pressure in the back-pressure turbine as low as technically feasible
cCondensing turbine for power production from excess steam
dHigh turbine efficiency
ePreheating feedwater to a temperature close to the boiling temperature
fPreheating the combustion air and fuel charged to the boilers

1.4.BAT CONCLUSIONS FOR MECHANICAL PULPING AND CHEMIMECHANICAL PULPINGU.K.

The BAT conclusions in this section apply to all integrated mechanical pulp, paper and board mills and to mechanical pulp mills, CTMP and CMP pulp mills. BAT 49, BAT 51, BAT 52c and BAT 53 also apply to papermaking in integrated mechanical pulp, paper and board mills, in addition to the BAT conclusions in this section.

1.4.1. Waste water and emissions to water U.K.
BAT 40.In order to reduce fresh water use, waste water flow, and the pollution load, BAT is to use a suitable combination of the techniques specified in BAT 13, BAT 14, BAT 15 and BAT 16 and of the techniques given below.U.K.
TechniqueDescriptionApplicability
aCounter-current flow of process water and separation of water systems.See Section 1.7.2.1Generally applicable
bHigh consistency bleaching.
cWashing stage before the refining of softwood mechanical pulp using chip pre-treatment.
dSubstitution of NaOH by Ca(OH)2 or Mg(OH)2 as alkali in peroxide bleaching.Applicability for the highest brightness levels may be restricted
eFibre and filler recovery and treatment of white water (papermaking).Generally applicable
fOptimum design and construction of tanks and chests (papermaking).
BAT-associated emission levels U.K.

See Table 16. These BAT-AELs also apply to mechanical pulp mills. The reference waste water flow for integrated mechanical, CTM and CTMP pulp mills are set out in BAT 5.

Table 16

BAT-associated emission levels for the direct waste water discharge to receiving waters from the integrated production of paper and board from mechanical pulps produced on site

a

In the case of highly bleached mechanical pulp (70-100 % of fibre in final paper), emission levels of up to 8 kg/t may occur.

b

When biodegradable or eliminable chelating agents cannot be used due to pulp quality requirements (e.g. high brightness), the emissions of total nitrogen might be higher than this BAT-AEL and should be assessed on a case-by-case basis.

ParameterYearly averagekg/t
Chemical oxygen demand (COD)0,9 – 4,5a
Total suspended solids (TSS)0,06 – 0,45
Total nitrogen0,03 – 0,1b
Total phosphorus0,001 – 0,01
Table 17

BAT-associated emission levels for the direct waste water discharge to receiving waters from a CTMP or CMP pulp mill

a

When biodegradable or eliminable chelating agents cannot be used due to pulp quality requirements (e.g. high brightness), the emissions of total nitrogen might be higher than this BAT- AEL and should be assessed on a case-by-case basis.

ParameterYearly averagekg/ADt
Chemical oxygen demand (COD)12 – 20
Total suspended solids (TSS)0,5 – 0,9
Total nitrogen0,15 – 0,18a
Total phosphorus0,001 – 0,01

The BOD concentration in the treated effluents is expected to be low (around 25 mg/l as a 24-hour composite sample).

1.4.2. Energy consumption and efficiency U.K.
BAT 41.In order to reduce the consumption of thermal and electrical energy, BAT is to use a combination of the techniques given below.U.K.
TechniqueApplicability
aUse of energy efficient refinersApplicable when replacing, rebuilding or upgrading process equipment
bExtensive recovery of secondary heat from TMP and CTMP refiners and reuse of recovered steam in paper or pulp dryingGenerally applicable
cMinimisation of fibre losses by using efficient reject refining systems (secondary refiners)
dInstallation of energy saving equipment, including automated process control instead of manual systems
eReduction of fresh water use by internal process water treatment and recirculation systems
fReduction of the direct use of steam by careful process integration using e.g. pinch analysis

1.5.BAT CONCLUSIONS FOR PROCESSING PAPER FOR RECYCLINGU.K.

The BAT conclusions in this section apply to all integrated RCF mills and to RCF pulp mills. BAT 49, BAT 51, BAT 52c and BAT 53 also apply to papermaking in integrated RCF pulp, paper and board mills, in addition to the BAT conclusions in this section.

1.5.1. Materials management U.K.
BAT 42.In order to prevent the contamination of soil and groundwater or to reduce the risk thereof and in order to reduce wind drift of paper for recycling and diffuse dust emissions from the paper for recycling yard, BAT is to use one or a combination of the techniques given below.U.K.
TechniqueApplicability
aHard surfacing of the storage area for paper for recyclingGenerally applicable
bCollection of contaminated run-off water from the paper for recycling storage area and treatment in a waste water treatment plant (uncontaminated rainwater e.g. from roofs can be discharged separately)Applicability may be restricted by the degree of contamination of run-off water (low concentration) and/or the size of the waste water treatment plants (large volumes)
cSurrounding the terrain of the paper for recycling yard with fences against wind driftGenerally applicable
dRegularly cleaning the storage area and sweeping associated roadways and emptying gully pots to reduce diffuse dust emissions. This reduces wind-blown paper debris, fibres and the crushing of paper by on-site traffic, which can cause additional dust emission, especially in the dry seasonGenerally applicable
eStoring of bales or loose paper under a roof to protect the material from weather influences (moisture, microbiological degradation processes, etc.)Applicability may be restricted by the size of the area
1.5.2. Waste water and emissions to water U.K.
BAT 43.In order to reduce fresh water use, waste water flow, and the pollution load, BAT is to use a combination of the techniques given below.U.K.
TechniqueDescription
aSeparation of the water systemsSee Section 1.7.2.1
bCounter-current flow of process water and water recirculation
cPartial recycling of treated waste water after biological treatmentMany RCF paper mills recycle a partial stream of biologically treated waste water back into the water circuit, especially mills producing corrugated medium or Testliner
dClarification of white waterSee Section 1.7.2.1
BAT 44.In order to maintain advanced water circuit closure in mills processing paper for recycling and to avoid possible negative effects from the increased recycling of process water, BAT is to use one or a combination of the techniques given below.U.K.
TechniqueDescription
aMonitoring and continuous control of the process water qualitySee Section 1.7.2.1
bPrevention and elimination of biofilms by using methods that minimise emissions of biocides
cRemoval of calcium from process water by a controlled precipitation of calcium carbonate
Applicability U.K.

Techniques (a) – (c) are applicable to RCF paper mills with advanced water circuit closure.

BAT 45.In order to prevent and reduce the pollution load of waste water into receiving waters from the whole mill, BAT is to use a suitable combination of the techniques specified in BAT 13, BAT 14, BAT 15, BAT 16, BAT 43 and BAT 44.U.K.

For integrated RCF paper mills, the BAT-AELs include emissions from papermaking, since the white water circuits of the paper machine are closely connected with those of the stock preparation.

BAT-associated emission levels U.K.

See Table 18 and Table 19.

The BAT-associated emission levels in Table 18 apply also to RCF without deinking pulp mills, and the BAT-associated emission levels in Table 19 apply also to RCF with deinking pulp mills.

The reference waste water flow for RCF mills is set out in BAT 5.

Table 18

BAT-associated emission levels for the direct waste water discharge to receiving waters from the integrated production of paper and board from recycled fibres pulp, produced without deinking on site

a

For mills with completely closed water circuits, there are no emissions of COD.

b

For existing plants, levels up to 0,45 kg/t may occur, due to the continuous decline in the quality of paper for recycling and the difficulty of continuously upgrading the effluent plant.

c

For mills with a waste water flow between 5 and 10 m3/t, the upper end of the range is 0,008 kg/t.

ParameterYearly averagekg/t
Chemical oxygen demand (COD)0,4a – 1,4
Total suspended solids (TSS)0,02 – 0,2b
Total nitrogen0,008 – 0,09
Total phosphorus0,001 – 0,005c
Adsorbable organically bound halogens (AOX)0,05 for wet strength paper
Table 19

BAT-associated emission levels for the direct waste water discharge to receiving waters from the integrated production of paper and board from recycled fibres pulp produced with deinking on site

ParameterYearly averagekg/t
Chemical oxygen demand (COD)

0,9 – 3,0

0,9 – 4,0 for tissue paper

Total suspended solids (TSS)

0,08 – 0,3

0,1 – 0,4 for tissue paper

Total nitrogen

0,01 – 0,1

0,01 – 0,15 for tissue paper

Total phosphorus

0,002 – 0,01

0,002 – 0,015 for tissue paper

Adsorbable organically bound halogens (AOX)0,05 for wet strength paper

The BOD concentration in the treated effluents is expected to be low (around 25 mg/l as a 24-hour composite sample).

1.5.3. Energy consumption and efficiency U.K.
BAT 46.BAT is to reduce electrical energy consumption within RCF processing paper mills by using a combination of the techniques given below.U.K.
TechniqueApplicability
aHigh consistency pulping for disintegrating paper for recycling into separated fibresGenerally applicable for new plants and for existing plants in the case of a major refurbishment
bEfficient coarse and fine screening by optimising rotor design, screens and screen operation, which allows the use of smaller equipment with lower specific energy consumption
cEnergy saving stock preparation concepts extracting impurities as early as possible in the re-pulping process, using fewer and optimised machine components, thus restricting the energy intensive processing of the fibres

1.6.BAT CONCLUSIONS FOR PAPERMAKING AND RELATED PROCESSESU.K.

The BAT conclusions in this section apply to all non-integrated paper mills and board mills and to the paper and board making part of integrated kraft, sulphite, CTMP and CMP mills.

BAT 49, BAT 51, BAT 52c and BAT 53 apply to all integrated pulp and paper mills.

For integrated kraft, sulphite, CTMP and CMP pulp and paper mills, the process-specific BAT for pulping also apply, in addition to the BAT conclusions in this section.

1.6.1. Waste water and emissions to water U.K.
BAT 47.In order to reduce the generation of waste water, BAT is to use a combination of the techniques given below.U.K.
TechniqueDescriptionApplicability
aOptimum design and construction of tanks and chestsSee Section 1.7.2.1Applicable to new plants and to existing plants in the case of a major refurbishment
bFibre and filler recovery and treatment of white waterGenerally applicable
cWater recirculationGenerally applicable. Dissolved organic, inorganic, and colloidal materials may restrict the water reuse in the wire section
dOptimisation of showers in the paper machineGenerally applicable
BAT 48.In order to reduce fresh water use and emissions to water from speciality paper mills, BAT is to use a combination of the techniques given below.U.K.
TechniqueDescriptionApplicability
aImprovement of paper production planningImproved planning to optimise production batch combinations and lengthGenerally applicable
bManagement of water circuits to fit changesAdjust water circuits to be able to cope with changes of paper grades, colours and chemical additives used
cWaste water treatment plant ready to cope with changesAdjust waste water treatment to be able to cope with variations of flows, low concentrations and varying types and amounts of chemical additives
dAdjustment of the broke system and of chest capacities
eMinimisation of release of chemical additives (e.g. grease-/water proof agents) containing per- or polyflourinated compounds or contributing to their formationApplicable only for plants producing paper with grease- or water-repellent properties
fSwitch to low AOX-containing product aids (e.g. to substitute use of wet strength agents based on epichlorohydrin resins)Applicable only for plants producing paper grades with high wet strength
BAT 49.In order to reduce emission loads of coating colours and binders which can disturb the biological waste water treatment plant, BAT is to use technique (a) given below or, in case this is technically not feasible, technique (b) given below.U.K.
TechniqueDescriptionApplicability
aRecovery of coating colours/recycling of pigments

Effluents containing coating colours are collected separately. The coating chemicals are recovered by e.g.:

(i)

ultrafiltration;

(ii)

screening-flocculation-dewatering process with return of the pigments to the coating process. The clarified water could be reused in the process

For ultrafiltration, the applicability may be restricted when:

  • effluent volumes are very small

  • coating effluents are generated in various places of the mill

  • many changes in coating occur; or

  • different coating colour recipes are incompatible

bPretreatment of effluents which contain coating coloursEffluents which contain coating colours are treated e.g. by flocculation to protect the subsequent biological waste water treatmentGenerally applicable
BAT 50.In order to prevent and reduce the pollution load of waste water into receiving waters from the whole mill, BAT is to use a suitable combination of the techniques specified in BAT 13, BAT 14, BAT 15, BAT 47, BAT 48 and BAT 49.U.K.
BAT-associated emission levels U.K.

See Table 20 and Table 21.

The BAT-AELs in Table 20 and Table 21 also apply to the paper and board making process of integrated kraft, sulphite, CTMP and CMP pulp and paper mills.

The reference waste water flow for non-integrated paper and board mills is set out in BAT 5.

Table 20

BAT-associated emission levels for the direct waste water discharge to receiving waters from a non-integrated paper and board mill (excluding speciality paper)

a

For graphic paper mills, the upper end of the range refers to mills manufacturing paper that use starch for the coating process.

ParameterYearly averagekg/t
Chemical oxygen demand (COD)0,15 – 1,5a
Total suspended solids (TSS)0,02 – 0,35
Total nitrogen

0,01 – 0,1

0,01 – 0,15 for tissue paper

Total phosphorus0,003 – 0,012
Adsorbable organically bound halogens (AOX)0,05 for decor and wet strength paper

The BOD concentration in the treated effluents is expected to be low (around 25 mg/l as a 24-hour composite sample).

Table 21

BAT-associated emission levels for the direct waste water discharge to receiving waters from a non-integrated speciality paper mill

a

Mills having special characteristics, such as a high number of grade changes (e.g. of ≥ 5 per day as a yearly average) or producing very light-weight speciality papers (≤ 30 g/m2 as yearly average) might have higher emissions than the upper end of the range.

b

The upper end of the BAT-AEL range refers to mills producing highly comminuted paper which requires intensive refining and to mills with frequent changes of paper grades (e.g. ≥ 1 – 2 changes/day as yearly average).

ParameterYearly averagekg/ta
Chemical oxygen demand (COD)0,3 – 5b
Total suspended solids (TSS)0,10 – 1
Total nitrogen0,015 – 0,4
Total phosphorus0,002 – 0,04
Adsorbable organically bound halogens (AOX)0,05 for decor and wet strength paper
1.6.2. Emissions to air U.K.
BAT 51.In order to reduce VOC emissions from off-line or on-line coaters, BAT is to choose coating colour recipes (compositions) that reduce VOC emissions.U.K.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.6.3. Waste generation U.K.
BAT 52.In order to minimise the amount of solid waste to be disposed of, BAT is to prevent waste generation and to carry out recycling operations by the use of a combination of the techniques given below (see general BAT 20).U.K.
TechniqueDescriptionApplicability
aFibre and filler recovery and treatment of white waterSee Section 1.7.2.1Generally applicable
bBroke recirculation systemBroke from different locations/phases of paper making process is collected, re-pulped and returned to the fibre feedstockGenerally applicable
cRecovery of coating colours/recycling of pigmentsSee Section 1.7.2.1
dReuse of fibre sludge from primary waste water treatmentSludge with a high fibre content from the primary treatment of waste water can be reutilised in a production processApplicability may be limited by product quality requirements
1.6.4. Energy consumption and efficiency U.K.
BAT 53.In order to reduce the consumption of thermal and electrical energy, BAT is to use a combination of the techniques given below.U.K.
TechniqueApplicability
aEnergy saving screening techniques (optimised rotor design, screens and screen operation)Applicable to new mills or major refurbishments
bBest practice refining with heat recovery from the refiners
cOptimised dewatering in the press section of paper machine/wide nip pressNot applicable to tissue paper and many speciality papers grades
dSteam condensate recovery and use of efficient exhaust air heat recovery systemsGenerally applicable
eReduction of direct use of steam by careful process integration using e.g. pinch analysis
fHigh efficient refinersApplicable to new plants
gOptimisation of the operating mode in existing refiners (e.g. reduction of ‘no load power requirements)Generally applicable
hOptimised pumping design, variable speed drive control for pumps, gearless drives
iCutting edge refining technologies
jSteam box heating of the paper web to improve the drainage properties/dewatering capacityNot applicable to tissue paper and many speciality papers grades
kOptimised vacuum system (e.g. turbo fans instead of water ring pumps)Generally applicable
lGeneration optimisation and distribution network maintenance
mOptimisation of heat recovery, air system, insulation
nUse of high efficient motors (EFF1)
oPreheating of shower water with a heat exchanger
pUse of waste heat for sludge drying or upgrading of dewatered biomass
qHeat recovery from axial blowers (if used) for the supply air of the drying hood
rHeat recovery of exhaust air from the Yankee hood with a trickling tower
sHeat recovery from the infrared exhaust hot air

1.7.DESCRIPTION OF TECHNIQUESU.K.

1.7.1. Description of techniques for the prevention and control of emissions to air U.K.
1.7.1.1. Dust U.K.
TechniqueDescription
Electrostatic precipitator (ESP)Electrostatic precipitators operate such that particles are charged and separated under the influence of an electrical field. They are capable of operating over a wide range of conditions.
Alkaline scrubberSee Section 1.7.1.3 (wet scrubber).
1.7.1.2. NOx U.K.
TechniqueDescription
Reduction of air/fuel ratio

The technique is mainly based on the following features:

  • careful control of air used for combustion (low excess oxygen),

  • minimisation of air leakages into the furnace,

  • modified design of the furnace combustion chamber.

Optimised combustion and combustion control

Based on permanent monitoring of appropriate combustion parameters (e.g. O2, CO content, fuel/air ratio, un-burnt components), this technique uses control technology for achieving the best combustion conditions.

NOx formation and emissions can be decreased by adjusting the running parameters, the air distribution, excess oxygen, flame shaping and the temperature profile.

Staged incinerationStaged incineration is based on the use of two burning zones, with controlled air ratios and temperatures in a first chamber. The first burning zone operates at sub-stoichiometric conditions to convert ammonia compounds into elementary nitrogen at high temperature. In the second zone, additional air feed completes combustion at a lower temperature. After the two-stage incineration, the flue-gas flows to a second chamber to recover the heat from the gases, producing steam to the process.
Fuel selection/low-N fuel

The use of fuels with a low nitrogen content reduces the amount of NOx emissions from the oxidation of nitrogen contained in the fuel during combustion.

The combustion of CNCG or biomass-based fuels increases NOx emissions compared to oil and natural gas, as CNCG and all wood-derived fuels contain more nitrogen than oil and natural gas.

Due to higher combustion temperatures, gas firing leads to higher NOx levels than oil firing.

Low-NOx burnerLow-NOx burners are based on the principles of reducing peak flame temperatures, delaying but completing the combustion and increasing the heat transfer (increased emissivity of the flame). It may be associated with a modified design of the furnace combustion chamber.
Staged injection of spent liquorThe injection of spent sulphite liquor into the boiler at various vertically staged levels prevents the formation of NOx, and provides for complete combustion.
Selective non-catalytic reduction (SNCR)The technique is based on the reduction of NOx to nitrogen by reaction with ammonia or urea at a high temperature. Ammonia water (up to 25 % NH3), ammonia precursor compounds or urea solution is injected into the combustion gas to reduce NO to N2. The reaction has an optimum effect in a temperature window of about 830 °C to 1 050 °C, and sufficient retention time must be provided for the injected agents to react with NO. Dosing rates of ammonia or urea have to be controlled to keep NH3 slip at low levels.
1.7.1.3. SO2/TRS emissions prevention and control U.K.
TechniqueDescription
High dry solid black liquorWith a higher dry solid content of the black liquor, the combustion temperature increases. This vaporises more sodium (Na), which can bind the SO2 forming Na2SO4 thus reducing SO2 emissions from the recovery boiler. A drawback to the higher temperature is that emissions of NOx may increase
Fuel selection/low-S fuelThe use of low-sulphur content fuels with a sulphur content of about 0,02 – 0,05 % by weight (e.g. forest biomass, bark, low-sulphur oil, gas) reduces SO2 emissions generated by the oxidation of sulphur in the fuel during combustion
Optimised firingTechniques such as efficient firing rate control system (air-fuel, temperature, residence time), control of excess oxygen or good mixing of air and fuel
Control of Na2S content in lime mud feedEfficient washing and filtration of the lime mud reduces the concentration of Na2S, thus reducing the formation of hydrogen sulphide in the kiln during the re-burning process
Collection and recovery of SO2 emissionsHighly concentrated SO2-gas streams from acid liquor production, digesters, diffusers or blow tanks are collected. SO2 is recovered in absorption tanks with different pressure levels, both for economic and environmental reasons
Incineration of odorous gases and TRSCollected strong gases can be destroyed by burning them in the recovery boiler, in dedicated TRS burners, or in the lime kiln. Collected weak gases are suitable for burning in the recovery boiler, lime kiln, power boiler or in the TRS burner. Dissolving tank vent gases can be burnt in modern recovery boilers
Collection and incineration of weak gases in a recovery boiler

Combustion of weak gases (large volume, low SO2 concentrations) combined with a back-up system.

Weak gases and other odorous components are simultaneously collected to be burnt in the recovery boiler. From the exhaust gas of the recovery boiler, the sulphur dioxide is then recovered by counter-current multistage scrubbers and reused as a cooking chemical. As a back-up system, scrubbers are used.

Wet scrubberGaseous compounds are dissolved in a suitable liquid (water or alkaline solution). Simultaneous removal of solid and gaseous compounds may be achieved. Downstream of the wet scrubber, the flue-gases are saturated with water and a separation of the droplets is required before discharging the flue-gases. The resulting liquid has to be treated by a waste water process and the insoluble matter is collected by sedimentation or filtration
ESP or multicyclones with multistage venturi scrubbers or multistage double inlet downstream scrubbersThe separation of dust is carried out in an electrostatic precipitator or multistage cyclone. For the magnesium sulphite process, the dust retained in the ESP consists mainly of MgO but also to a minor extent, K, Na or Ca compounds. The recovered MgO ash is suspended with water and cleaned by washing and slaking to form Mg(OH)2 which is then used as an alkaline scrubbing solution in the multistage scrubbers in order to recover the sulphur component of the cooking chemicals. For the ammonium sulphite process, the ammonia base (NH3) is not recovered, as it is decomposed in the combustion process in nitrogen. After the removal of dust, the flue-gas is cooled down by passing through a cooling scrubber operated with water and it then enters a three or more staged scrubber of the flue-gas where the SO2 emissions are scrubbed with the Mg(OH)2 alkaline solution in the case of the magnesium sulphite process, and with a 100 % fresh NH3 solution in the case of the ammonium sulphite process.
1.7.2. Description of techniques to reduce fresh water use/waste water flow and the pollution load in waste water U.K.
1.7.2.1. Process integrated techniques U.K.
TechniqueDescription
Dry debarkingDry debarking of wood logs in dry tumbling drums (water being used only in washing of the logs, and then recycled with only a minimum purge to the waste water treatment plant)
Totally chlorine free bleaching (TCF)In TCF bleaching, the use of chlorine containing bleaching chemicals is completely avoided and thus so are the emissions of organic and organochlorinated substances from bleaching
Modern elemental chlorine free (ECF) bleachingModern ECF bleaching minimises the consumption of chlorine dioxide by using one or a combination of the following bleaching stages: oxygen, hot acid hydrolysis stage, ozone stage at medium and high consistency, stages with atmospheric hydrogen peroxide and pressurised hydrogen peroxide or the use of a hot chlorine dioxide stage
Extended delignificationExtended delignification by (a) modified cooking or (b) oxygen delignification enhances the degree of delignification of pulp (lowering the kappa number) before bleaching and thus reduces the use of bleaching chemicals and the COD load of waste water. Lowering the kappa number by one unit before bleaching can reduce the COD released in the bleach plant by approximately 2 kg COD/ADt. The lignin removed can be recovered and sent to the chemicals and energy recovery system
(a)Extended modified cooking
Extended cooking (batch or continuous systems) comprises longer cooking periods under optimised conditions (e.g. alkali concentration in the cooking liquor is adjusted to be lower at the beginning and higher at the end of the cooking process), to extract a maximum amount of lignin before bleaching, without undue carbohydrate degradation or excessive loss of pulp strength. Thus, the use of chemicals in the subsequent bleaching stage and the organic load of the waste water from the bleach plant can be reduced
(b)Oxygen delignification
Oxygen delignification is an option to remove a substantial fraction of the lignin remaining after cooking, in case the cooking plant has to be operated with higher kappa numbers. The pulp reacts under alkaline conditions with oxygen to remove some of the residual lignin
Closed and efficient brown stock screening and washing

Brown stock screening is carried out with slotted pressure screens in a multistage closed cycle. Impurities and shives are thus removed at an early stage in the process.

Brown stock washing separates dissolved organic and inorganic chemicals from the pulp fibres. The brown stock pulp may be washed first in the digester, then in high-efficiency washers before and after oxygen delignification, i.e. before bleaching. Carry-over, chemical consumption in bleaching, and the emission load of waste water are all reduced. Additionally, it allows for recovery of the cooking chemicals from the washing water. Efficient washing is done by counter-current multistage washing, using filters and presses. The water system in the brown stock screening plant is completely closed

Partial process water recycling in the bleach plant

Acid and alkaline filtrates are recycled within the bleach plant counter-currently to the pulp flow. Water is purged either to the waste water treatment plant or, in a few cases, to post-oxygen washing.

Efficient washers in the intermediate washing stages are a prerequisite for low emissions. A bleach plant effluent flow of 12 – 25 m3/ADt is achieved in efficient mills (Kraft)

Effective spill monitoring and containment, also with chemical and energy recovery

An effective spill control, catchment and recovery system that prevents accidental releases of high organic and sometimes toxic loads or peak pH values (to the secondary waste water treatment plant) comprises:

  • conductivity or pH monitoring at strategic locations to detect losses and spills;

  • collecting diverted or spilled liquor at the highest possible liquor solids concentration;

  • returning collected liquor and fibre to the process at appropriate locations;

  • preventing spills of concentrated or harmful flows from critical process areas (including tall oil and turpentine) from entering the biological effluent treatment;

  • adequately dimensioned buffer tanks for collecting and storing toxic or hot concentrated liquors

Maintaining sufficient black liquor evaporation and recovery boiler capacity to cope with peak loads

Sufficient capacity in the black liquor evaporation plant and in the recovery boiler ensure that additional liquor and dry solids loads due to the collection of spills or bleach plant effluents can be dealt with. This reduces losses of weak black liquor, other concentrated process effluents and potentially bleach plant filtrates.

The multi-effect evaporator concentrates weak black liquor from brown stock washing and, in some cases, also biosludge from the effluent treatment plant and/or salt cake from the ClO2 plant. Additional evaporation capacity above normal operation gives sufficient contingency to recover spills and to treat potential bleach filtrate recycle streams

Stripping the contaminated (foul) condensates and reusing the condensates in the process

Stripping of contaminated (foul) condensates and reuse of condensates in the process reduces the fresh water intake of a mill and the organic load to the waste water treatment plant.

In a stripping column, steam is lead counter-currently through the previously filtered process condensates that contain reduced sulphur compounds, terpenes, methanol and other organic compounds. The volatile substances of the condensate accumulate in the overhead vapour as non-condensable gases and methanol and are withdrawn from the system. The purified condensates can be reused in the process, e.g. for washing in the bleach plant, in brown stock washing, in the causticising area (mud washing and dilution, mud filter showers), as TRS scrubbing liquor for lime kilns, or as white liquor make-up water.

The stripped non-condensable gases from the most concentrated condensates are fed into the collection system for strong malodorous gases and are incinerated. Stripped gases from moderately contaminated condensates are collected into the low volume high concentration gas system (LVHC) and incinerated

Evaporating and incinerating effluents from the hot alkaline extraction stageThe effluents are first concentrated by evaporation and then combusted as biofuel in a recovery boiler. Sodium carbonate containing dust and melt from the furnace bottom are dissolved to recover soda solution
Recirculation of washing liquids from pre-bleaching to brown stock washing and evaporation to reduce emissions from MgO-based pre-bleaching

Prerequisites for the use of this technique are a relatively low kappa number after cooking (e.g. 14 – 16), sufficient capacity of tanks, evaporators and recovery boiler to cope with additional flows, the possibility to clean the washing equipment from deposits, and a moderate brightness level of the pulp (≤ 87 % ISO) as this technique may lead to a slight loss of brightness in some cases.

For market paper pulp producers or others that have to reach very high brightness levels (> 87 % ISO), it may be difficult to apply MgO pre-bleaching

Counter-current flow of process waterIn integrated mills, fresh water is introduced mainly through the paper machine showers from which it is fed upstream towards the pulping department
Separation of water systemsWater systems of different process units (e.g. pulping unit, bleaching and paper machine) are separated by washing and dewatering the pulp (e.g. by wash presses). This separation prevents carry-over of pollutants to subsequent process steps and allows for removing disturbing substances from smaller volumes
High consistency (peroxide) bleachingFor high consistency bleaching, the pulp is dewatered e.g. by a twin wire or other press before bleaching chemicals are added. This allows for more efficient use of bleaching chemicals and results in a cleaner pulp, less carry-over of detrimental substances to the paper machine and generates less COD. Residual peroxide may be recirculated and reused
Fibre and filler recovery and treatment of white water

White water from the paper machine can be treated by the following techniques:

a)

‘Save-all’ devices (typically drum or disc filter or dissolved air flotation units etc.) that separate solids (fibres and filler) from the process water. Dissolved air flotation in white water loops transforms suspended solids, fines, small-size colloidal material and anionic substances into flocks that are then removed. The recovered fibres and fillers are recirculated to the process. Clear white water can be reused in showers with less stringent requirements for water quality.

b)

Additional ultrafiltration of the pre-filtered white water results in super clear filtrate with a quality sufficient for use as high pressure shower water, sealing water and for the dilution of chemical additives

Clarification of white waterThe systems for water clarification used almost exclusively in the paper industry are based on sedimentation, filtration (disc filter) and flotation. The most used technique is dissolved air flotation. Anionic trash and fines are agglomerated into physically treatable flocs by using additives. High-molecular, water-soluble polymers or inorganic electrolytes are used as flocculants. The generated agglomerates (flocs) are then floated off in the clarification basin. In dissolved air flotation (DAF), the suspended solid material is attached to air bubbles
Water recirculationClarified water is recirculated as process water within a unit or in integrated mills from the paper machine to the pulp mill and from the pulping to the debarking plant. Effluent is mainly discharged from the points with the highest pollution load (e.g. clear filtrate of the disc filter in pulping, debarking)
Optimum design and construction of tanks and chests (papermaking)Holding tanks for stock and white water storage are designed so that they can cope with process fluctuations and varying flows also during start-ups and shutdowns
Washing stage before refining softwood mechanical pulpSome mills pretreat softwood chips by combining pressurised preheating, high compression and impregnation to improve pulp properties. A washing stage before refining and bleaching significantly reduces COD by removing a small, but highly concentrated effluent stream that can be treated separately
Substitution of NaOH by Ca(OH)2 or Mg (OH)2 as alkali in peroxide bleachingThe use of Ca(OH)2 as alkali results in approximately 30 % lower COD emission loads; while keeping brightness levels high. Also Mg(OH)2 is used to replace NaOH
Closed-loop bleachingIn sulphite pulp mills using sodium as a cooking base, the bleach plant effluent can be treated, e.g. by ultrafiltration, flotation and separation of resin and fatty acids which enables closed-loop bleaching. The filtrates from bleaching and washing are reused in the first washing stage after cooking and finally recycled back to the chemical recovery units
pH adjustment of weak liquor before/inside the evaporation plantNeutralisation is done before evaporation or after the first evaporation stage, to keep organic acids dissolved in the concentrate, in order for them to be sent with the spent liquor to the recovery boiler
Anaerobic treatment of the condensates from the evaporatorsSee Section 1.7.2.2 (combined anaerobic/aerobic treatment)
Stripping and recovery of SO2 from condensates of evaporatorsSO2 is stripped from the condensates; concentrates are treated biologically, while the stripped SO2 is sent for recovery as a cooking chemical.
Monitoring and continuous control of the process water qualityOptimisation of the entire ‘fibre-water-chemical additive-energy system’ is necessary for advanced closed water systems. This requires a continuous monitoring of the water quality and staff motivation, knowledge and action related to the measures needed to ensure the required water quality
Prevention and elimination of biofilms by using methods that minimise emissions of biocidesA continuous input of microorganisms by water and fibres leads to a specific microbiological equilibrium in each paper plant. To prevent extensive growth of the microorganisms, deposits of agglomerated biomass or biofilms in water circuits and equipment, often bio-dispersants or biocides are used. When using catalytic disinfection with hydrogen peroxide, biofilms and free germs in process water and paper slurry are eliminated [X1by using methods that minimise emissions of biocides]
Removal of calcium from process water by controlled precipitation of calcium carbonateLowering the calcium concentration by controlled removal of calcium carbonate (e.g. in a dissolved air flotation cell) reduces the risk of undesired precipitation of calcium carbonate or scaling in water systems and equipment, e.g. in section rolls, wires, felts and shower nozzles, pipes or biological waste water treatment plants
Optimisation of showers in paper machineOptimising showers involves: a) the reuse of process water (e.g. clarified white water) to reduce fresh water use, and b) the application of special design nozzles for the showers
1.7.2.2. Waste water treatment U.K.
TechniqueDescription
Primary treatment

Physico-chemical treatment, such as equalisation, neutralisation or sedimentation.

Equalisation (e.g. in equalising basins) is used to prevent large variations in flow rate, temperature and contaminant concentrations and thus to avoid overloading the waste water treatment system

Secondary (biological) treatmentFor the treatment of waste water by means of microorganisms, the available processes are aerobic and anaerobic treatment. In a secondary clarification step, solids and biomass are separated from effluents by sedimentation, sometimes combined with flocculation
a)Aerobic treatment

In aerobic biological waste water treatment, biodegradable dissolved and colloidal material in the water is transformed in the presence of air by microorganisms partly into a solid cell substance (biomass) and partly into carbon dioxide and water. Processes used are:

  • one- or two-stage activated sludge;

  • biofilm reactor processes;

  • biofilm/activated sludge (compact biological treatment plant). This technique consists in combining moving bed carriers with activated sludge (BAS).

The generated biomass (excess sludge) is separated from the effluent before the water is discharged

b)Combined anaerobic/aerobic treatment

Anaerobic waste water treatment converts the organic content of waste water by means of microorganisms in the absence of air, into methane, carbon dioxide, sulphide, etc. The process is carried out in an airtight tank reactor. The microorganisms are retained in the tank as biomass (sludge). The biogas formed by this biological process consists of methane, carbon dioxide and other gases such as hydrogen and hydrogen sulphide and is suitable for energy generation.

Anaerobic treatment is to be seen as pretreatment before aerobic treatment, due to the remaining COD loads. Anaerobic pretreatment reduces the amount of sludge generated from biological treatment

Tertiary treatmentAdvanced treatment comprises techniques, such as filtration for further solids removal, nitrification and denitrification for nitrogen removal or flocculation/precipitation followed by filtration for phosphorus removal. Tertiary treatment is normally used in cases where primary and biological treatment are not sufficient to achieve low levels of TSS, nitrogen or phosphorus, which may be required e.g. due to local conditions
Properly designed and operated biological treatment plantA properly designed and operated biological treatment plant includes the appropriate design and dimensioning of treatment tanks/basins (e.g. sedimentation tanks) according to hydraulic and contaminant loads. Low TSS emissions are achieved by ensuring the good settling of the active biomass. Periodical revisions of the design, dimensioning and operation of the waste water treatment plant facilitate achieving these objectives
1.7.3. Description of techniques for waste generation prevention and waste management U.K.
TechniqueDescription
Waste assessment and waste management systemWaste assessment and waste management systems are used to identify feasible options for optimising prevention, reuse, recovery, recycling and final disposal of waste. Waste inventories allow for identifying and classifying type, characteristics, amount and origin of each waste fraction
Separate collection of different waste fractionsThe separate collection of different waste fractions at the points of origin and, if appropriate, intermediate storage can enhance the options for reuse or recirculation. Separate collection also includes segregation and classification of hazardous waste fractions (e.g. oil and grease residues, hydraulic and transformer oils, waste batteries, scrap electrical equipment, solvents, paints, biocides or chemical residues)
Merging of suitable residue fractionsMerging of suitable fractions of residue depending on the preferred options for reuse/recycling, further treatment and disposal
Pretreatment of process residues before reuse or recycling

Pretreatment comprises techniques such as:

  • dewatering e.g. of sludge, bark or rejects and in some cases drying to enhance reusability before utilisation (e.g. increase calorific value before incineration); or

  • dewatering to reduce weight and volume for transport. For dewatering belt presses, screw presses, decanter centrifuges or chamber filter presses are used;

  • crushing/shredding of rejects e.g. from RCF processes and removal of metallic parts, to enhance combustion characteristics before incineration;

  • biological stabilisation before dewatering, in case agricultural utilisation is foreseen

Material recovery and recycling of process residues on site

Processes for material recovery comprise techniques such as:

  • separation of fibres from water streams and recirculation into feedstock;

  • recovery of chemical additives, coating pigments, etc.;

  • recovery of cooking chemicals by means of recovery boilers, causticising, etc.

Energy recovery on- or off-site from wastes with high organic contentResidues from debarking, chipping, screening etc. like bark, fibre sludge or other mainly organic residues are burnt due to their calorific value in incinerators or biomass power plants for energy recovery
External material utilisation

Material utilisation of suitable waste from pulp and paper production can be done in other industrial sectors, e.g. by:

  • firing in the kilns or mixing with feedstock in cement, ceramics or bricks production (includes also energy recovery);

  • composting paper sludge or land spreading suitable waste fractions in agriculture;

  • use of inorganic waste fractions (sand, stones, grits, ashes, lime) for construction, such as paving, roads, covering layers etc.

The suitability of waste fractions for off-site utilisation is determined by the composition of the waste (e.g. inorganic/mineral content) and the evidence that the foreseen recycling operation does not cause harm to the environment or health

Pretreatment of waste fraction before disposalPretreatment of waste before disposal comprises measures (dewatering, drying etc.) reducing the weight and volume for transport or disposal

Back to top

Options/Help

Print Options

Close

Legislation is available in different versions:

Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.

Original (As adopted by EU): The original version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.

Point in Time: This becomes available after navigating to view revised legislation as it stood at a certain point in time via Advanced Features > Show Timeline of Changes or via a point in time advanced search.

Close

See additional information alongside the content

Geographical Extent: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.

Show Timeline of Changes: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.

Close

Opening Options

Different options to open legislation in order to view more content on screen at once

Close

More Resources

Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as adopted version that was used for the EU Official Journal
  • lists of changes made by and/or affecting this legislation item
  • all formats of all associated documents
  • correction slips
  • links to related legislation and further information resources
Close

Timeline of Changes

This timeline shows the different versions taken from EUR-Lex before exit day and during the implementation period as well as any subsequent versions created after the implementation period as a result of changes made by UK legislation.

The dates for the EU versions are taken from the document dates on EUR-Lex and may not always coincide with when the changes came into force for the document.

For any versions created after the implementation period as a result of changes made by UK legislation the date will coincide with the earliest date on which the change (e.g an insertion, a repeal or a substitution) that was applied came into force. For further information see our guide to revised legislation on Understanding Legislation.

Close

More Resources

Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as adopted version that was used for the print copy
  • correction slips

Click 'View More' or select 'More Resources' tab for additional information including:

  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • links to related legislation and further information resources