Search Legislation

Commission Delegated Regulation (EU) 2016/364Show full title

Commission Delegated Regulation (EU) 2016/364 of 1 July 2015 on the classification of the reaction to fire performance of construction products pursuant to Regulation (EU) No 305/2011 of the European Parliament and of the Council (Text with EEA relevance)

 Help about what version

What Version

 Help about advanced features

Advanced Features

 Help about UK-EU Regulation

Legislation originating from the EU

When the UK left the EU, legislation.gov.uk published EU legislation that had been published by the EU up to IP completion day (31 December 2020 11.00 p.m.). On legislation.gov.uk, these items of legislation are kept up-to-date with any amendments made by the UK since then.

Close

This item of legislation originated from the EU

Legislation.gov.uk publishes the UK version. EUR-Lex publishes the EU version. The EU Exit Web Archive holds a snapshot of EUR-Lex’s version from IP completion day (31 December 2020 11.00 p.m.).

Changes to legislation:

There are currently no known outstanding effects by UK legislation for Commission Delegated Regulation (EU) 2016/364. Help about Changes to Legislation

Close

Changes to Legislation

Revised legislation carried on this site may not be fully up to date. At the current time any known changes or effects made by subsequent legislation have been applied to the text of the legislation you are viewing by the editorial team. Please see ‘Frequently Asked Questions’ for details regarding the timescales for which new effects are identified and recorded on this site.

Commission Delegated Regulation (EU) 2016/364

of 1 July 2015

on the classification of the reaction to fire performance of construction products pursuant to Regulation (EU) No 305/2011 of the European Parliament and of the Council

(Text with EEA relevance)

THE EUROPEAN COMMISSION,

Having regard to the Treaty on the Functioning of the European Union,

Having regard to Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC(1), and in particular Article 27(1) thereof,

Whereas:

(1) A system for classifying the performance of construction products with regard to their reaction to fire was adopted by Commission Decision 2000/147/EC(2). It was based on a harmonised solution of assessing this performance and classifying the results of these assessments.

(2) Decision 2000/147/EC provides several classes of reaction to fire performance. In addition, it contains classes F, FFL, FL and Fca, which are defined as ‘no performance determined’.

(3) In accordance with Article 2(7) of Regulation (EU) No 305/2011, a class means a range of levels, delimited by a minimum and a maximum value of performance. Classes defined as ‘no performance determined’ do not correspond to this definition and thus cannot be incorporated in a classification system under Regulation (EU) No 305/2011.

(4) The use of ‘no performance determined’ in the context of drawing up the declaration of performance is provided in Article 6(3)(f) of Regulation (EU) No 305/2011.

(5) In order to enable the manufacturers to declare lower reaction to fire performance than that covered by classes E, EFL, EL and Eca, it is necessary to change the classification criteria of classes F, FFL, FL and Fca accordingly.

(6) It is therefore necessary to replace the classes F, FFL, FL and Fca provided in Decision 2000/147/EC with new classes for products not reaching at least the reaction to fire performance under the classes E, EFL, EL and Eca.

(7) Decision 2000/147/EC has been amended several times and further amendments to that Decision are necessary. In the interests of clarity and rationality that decision should therefore be repealed and replaced,

HAS ADOPTED THIS REGULATION:

Article 1U.K.

When the intended use of a construction product is such that the product may contribute to the generation and spread of fire and smoke within the room or area of origin or beyond, the performance of the product in relation to its reaction to fire shall be classified in accordance with the classification system set out in the Annex.

Article 2U.K.

Decision 2000/147/EC is repealed.

References to the repealed Decision shall be construed as references to this Regulation.

Article 3U.K.

This Regulation shall enter into force on the twentieth day following that of its publication in the Official Journal of the European Union.

This Regulation shall be binding in its entirety and directly applicable in all Member States.

Done at Brussels, 1 July 2015.

For the Commission

The President

Jean-Claude Juncker

ANNEXU.K. Classes of reaction to fire performance

1.1.For the purposes of Tables 1 to 4 the following symbols(3) apply:U.K.

(1) ‘ΔΤ’

temperature rise;

(2) ‘Δm’

mass loss;

(3) ‘tf

duration of flaming;

(4) ‘PCS’

gross calorific potential;

(5) ‘LFS’

lateral flame spread;

(6) ‘SMOGRA’

smoke growth rate.

1.2.For the purposes of Tables 1, 2 and 3 the following symbols(3) apply:U.K.

(1) ‘FIGRA’

fire growth rate;

(2) ‘THR’

total heat release;

(3) ‘TSP’

total smoke production;

(4) ‘Fs’

flame spread.

1.3.For the purposes of Table 4 the following symbols and test parameters apply:U.K.

(1) ‘HRRsm30, kW’

heat release rate averaged by a 30-s sliding average;

(2) ‘SPRsm60, m2/s’

smoke production rate averaged by a 60-s sliding average;

(3) ‘Peak HRR, kW’

maximum of HRRsm30 between test start and end of test, excluded contribution from ignition source;

(4) ‘Peak SPR, m2/s’

maximum of SPRsm60 between test start and end of test;

(5) ‘THR1200, MJ’

total heat release (HRRsm30) from test start until end of test, excluded contribution from ignition source;

(6) ‘TSP1200, m2

total smoke production (HRRsm60) from test start until end of test;

(7) ‘FIGRA, W/s’

fire growth rate index defined as the highest value of the quotient between HRRsm30 excluding the contribution of ignition source and time. Threshold values HRRsm30 = 3 kW and THR = 0,4 MJ;

(8) ‘FS’

flame spread (damaged length);

(9) ‘H’

flame spread.

2.For the purposes of Tables 1 to 4 the following definitions apply:U.K.

(1)

‘material’ means a single basic substance or uniformly dispersed mixture of substances;

(2)

‘homogeneous product’ means a product consisting of a single material, having uniform density and composition throughout the product;

(3)

‘non-homogeneous product’ means a product that does not satisfy the requirements of a homogeneous product and that is composed of one or more components, substantial and/or non-substantial;

(4)

‘substantial component’ means a material that constitutes a significant part of a non-homogeneous product; a layer with a mass per unit area ≥ 1,0 kg/m2 or a thickness ≥ 1,0 mm is considered to be a substantial component;

(5)

‘non-substantial component’ means a material that does not constitute a significant part of a non-homogeneous product; a layer with a mass per unit area < 1,0 kg/m2 and a thickness < 1,0 mm is considered to be a non-substantial component;

(6)

‘internal non-substantial component’ means a non-substantial component that is covered on both sides by at least one substantial component;

(7)

‘external non-substantial component’ means a non-substantial component that is not covered on one side by a substantial component.

Two or more non-substantial layers that are adjacent to each other, where there are no substantial components in between the layers, shall be considered as one non-substantial component and shall, therefore, be classified in accordance with the criteria for a layer that is a non-substantial component.

Table 1

Classes of reaction to fire performance for construction products excluding floorings, linear pipe thermal insulation products, and electric cables

a

For homogeneous products and substantial components of non-homogeneous products.

b

For any external non-substantial component of non-homogeneous products.

c
(2a)

Alternatively, any external non-substantial component having a PCS ≤ 2,0 MJm– 2, provided that the product satisfies the following criteria of EN 13823(SBI): FIGRA ≤ 20 Ws– 1; and LFS < edge of specimen; and THR600s ≤ 4,0 MJ; and s1; and d0.

d

For any internal non-substantial component of non-homogeneous products.

e

For the product as a whole.

f

s1 = SMOGRA ≤ 30m2s– 2 and TSP600s ≤ 50m2; s2 = SMOGRA ≤ 180m2s– 2 and TSP600s ≤ 200m2; s3 = not s1 or s2.

g

d0 = No flaming droplets/particles in EN 13823 (SBI) within 600s; d1 = No flaming droplets/particles persisting longer than 10s in EN 13823 (SBI) within 600s; d2 = not d0 or d1; Ignition of the paper in EN ISO 11925-2 results in a d2 classification.

h

No ignition of the paper = no additional classification; Ignition of the paper = d2 classification.

i

Under conditions of surface flame attack and, if appropriate to the intended use of the product, edge flame attack.

ClassTest method(s)Classification criteriaAdditional classification
A1

EN ISO 1182a;

and

ΔΤ ≤ 30 °C; and

Δm ≤ 50 %; and

tf = 0 (i.e. no sustained flaming)

EN ISO 1716

PCS ≤ 2,0 MJkg– 1 a; and

PCS ≤ 2,0 MJkg– 1 b c; and

PCS ≤ 1,4 MJm– 2 d; and

PCS ≤ 2,0 MJkg– 1 e

A2

EN ISO 1182a;

or

ΔΤ ≤ 50 °C; and

Δm ≤ 50 %; and

tf ≤ 20 s

EN ISO 1716;

and

PCS ≤ 3,0 MJkg– 1 a; and

PCS ≤ 4,0 MJm– 2 b; and

PCS ≤ 4,0 MJm– 2 d; and

PCS ≤ 3,0 MJkg– 1 e

EN 13823 (SBI)

FIGRA ≤ 120 Ws– 1; and

LFS < edge of specimen; and

THR600s ≤ 7,5 MJ

Smoke productionf; and

Flaming droplets/particlesg

B

EN 13823 (SBI);

and

FIGRA ≤ 120 Ws– 1; and

LFS < edge of specimen; and

THR600s ≤ 7,5 MJ

Smoke productionf; and

Flaming droplets/particlesg

EN ISO 11925-2i:

Exposure = 30 s

Fs ≤ 150 mm within 60 s
C

EN 13823 (SBI);

and

FIGRA ≤ 250 Ws– 1; and

LFS < edge of specimen; and

THR600s ≤ 15 MJ

Smoke productionf; and

Flaming droplets/particlesg

EN ISO 11925-2i:

Exposure = 30 s

Fs ≤ 150 mm within 60 s
D

EN 13823 (SBI);

and

FIGRA ≤ 750 Ws– 1

Smoke productionf; and

Flaming droplets/particlesg

EN ISO 11925-2i:

Exposure = 30 s

Fs ≤ 150 mm within 60 s
E

EN ISO 11925-2i:

Exposure = 15 s

Fs ≤ 150 mm within 20 sFlaming droplets/particlesh
F

EN ISO 11925-2i:

Exposure = 15 s

Fs > 150 mm within 20 s

Table 2

Classes of reaction to fire performance for floorings

a

For homogeneous products and substantial components of non-homogeneous products.

b

For any external non-substantial component of non-homogeneous products.

c

For any internal non-substantial component of non-homogeneous products.

d

For the product as a whole.

e

Test duration = 30 minutes.

f

Critical flux is defined as the radiant flux at which the flame extinguishes or the radiant flux after a test period of 30 minutes, whichever is the lower (i.e. the flux corresponding with the furthest extent of spread of flame).

g

s1 = Smoke ≤ 750 %.min; s2 = not s1.

h

Under conditions of surface flame attack and, if appropriate to the intended use of the product, edge flame attack.

ClassTest method(s)Classification criteriaAdditional classification
A1FL

EN ISO 1182a;

and

ΔΤ ≤ 30 °C; and

Δm ≤ 50 %; and

tf = 0 (i.e. no sustained flaming)

EN ISO 1716

PCS ≤ 2,0 MJkg– 1 a; and

PCS ≤ 2,0 MJkg– 1 b; and

PCS ≤ 1,4 MJm– 2 c; and

PCS ≤ 2,0 MJkg– 1 d

A2FL

EN ISO 1182a;

or

ΔΤ ≤ 50 °C; and

Δm ≤ 50 %; and

tf ≤ 20 s

EN ISO 1716;

and

PCS ≤ 3,0 MJkg– 1 a; and

PCS ≤ 4,0 MJm– 2 b; and

PCS ≤ 4,0 MJm– 2 c; and

PCS ≤ 3,0 MJkg– 1 d

EN ISO 9239-1eCritical fluxf ≥ 8,0 kWm– 2Smoke productiong
BFL

EN ISO 9239-1e

and

Critical fluxf ≥ 8,0 kWm– 2Smoke productiong

EN ISO 11925-2h:

Exposure = 15 s

Fs ≤ 150 mm within 20 s
CFL

EN ISO 9239-1e

and

Critical fluxf ≥ 4,5 kWm– 2Smoke productiong

EN ISO 11925-2h:

Exposure = 15 s

Fs ≤ 150 mm within 20 s
DFL

EN ISO 9239-1e

and

Critical fluxf ≥ 3,0 kWm– 2Smoke productiong

EN ISO 11925-2h:

Exposure = 15 s

Fs ≤ 150 mm within 20 s
EFL

EN ISO 11925-2h:

Exposure = 15 s

Fs ≤ 150 mm within 20 s
FFL

EN ISO 11925-2h:

Exposure = 15 s

Fs > 150 mm within 20 s

Table 3

Classes of reaction to fire performance for linear pipe insulation products

a

For homogeneous products and substantial components of non-homogeneous products.

b

For any external non-substantial component of non-homogeneous products.

c

For any internal non-substantial component of non-homogeneous products.

d

For the product as a whole.

e

s1 = SMOGRA ≤ 105 m2s– 2 and TSP600s ≤ 250 m2; s2 = SMOGRA ≤ 580 m2s– 2 and TSP600s ≤ 1 600 m2; s3 = not s1 or s2.

f

d0 = No flaming droplets/particles in EN13823 (SBI) within 600s; d1 = No flaming droplets/particles persisting longer than 10s in EN13823 (SBI) within 600s; d2 = not d0 or d1; Ignition of the paper in EN ISO 11925-2 results in a d2 classification.

g

No ignition of the paper = no additional classification; Ignition of the paper = d2 classification.

h

Under conditions of surface flame attack and, if appropriate to the intended use of the product, edge flame attack.

ClassTest method(s)Classification criteriaAdditional classification
A1L

EN ISO 1182a;

and

ΔT ≤ 30 °C; and

Δm ≤ 50 %; and

tf = 0 (i.e. no sustained flaming)

EN ISO 1716

PCS ≤ 2,0 MJkg– 1 a; and

PCS ≤ 2,0 MJkg– 1 b; and

PCS ≤ 1,4 MJm– 2 c; and

PCS ≤ 2,0 MJkg– 1 d

A2L

EN ISO 1182a;

or

ΔT ≤ 50 °C; and

Δm ≤ 50 %; and tf ≤ 20 s

EN ISO 1716;

and

PCS ≤ 3,0 MJkg– 1 a; and

PCS ≤ 4,0 MJm– 2 b; and

PCS ≤ 4,0 MJm– 2 c; and

PCS ≤ 3,0 MJkg– 1 d

EN 13823 (SBI)

FIGRA ≤ 270 Ws– 1; and

LFS < edge of specimen; and

THR600s ≤ 7,5 MJ

Smoke productione; and

Flaming droplets/particlesf

BL

EN 13823 (SBI);

and

FIGRA ≤ 270 Ws– 1; and

LFS < edge of specimen; and

THR600s ≤ 7,5 MJ

Smoke productione; and

Flaming droplets/particlesf

EN ISO 11925-2h:

Exposure = 30 s

Fs ≤ 150 mm within 60 s
CL

EN 13823 (SBI);

and

FIGRA ≤ 460 Ws– 1; and

LFS < edge of specimen; and

THR600s ≤ 15 MJ

Smoke productione; and

Flaming droplets/particlesf

EN ISO 11925-2h:

Exposure = 30 s

Fs ≤ 150 mm within 60 s
DL

EN 13823 (SBI);

and

FIGRA ≤ 2 100 Ws– 1

THR600s ≤ 100 MJ

Smoke productione; and

Flaming droplets/particlesf

EN ISO 11925-2h:

Exposure = 30 s

Fs ≤ 150 mm within 60 s
EL

EN ISO 11925-2h:

Exposure = 15 s

Fs ≤ 150 mm within 20 sFlaming droplets/particlesg
FL

EN ISO 11925-2h:

Exposure = 15 s

Fs > 150mm within 20 s

Table 4

Classes of reaction to fire performance for electric cables

a

For the product as a whole, excluding metallic materials, and for any external component (i.e. sheath) of the product.

b

s1 = TSP1200 ≤ 50 m2 and Peak SPR ≤ 0,25 m2/s

s1a = s1 and transmittance in accordance with EN 61034-2 ≥ 80 %

s1b = s1 and transmittance in accordance with EN 61034-2 ≥ 60 % < 80 %

s2 = TSP1200 ≤ 400 m2 and Peak SPR ≤ 1,5 m2/s

s3 = not s1 or s2

c

d0 = No flaming droplets/particles within 1 200 s; d1 = No flaming droplets/particles persisting longer than 10 s within 1 200 s; d2 = not d0 or d1.

d

EN 60754-2: a1 = conductivity < 2,5 μS/mm and pH > 4,3; a2 = conductivity < 10 μS/mm and pH > 4,3; a3 = not a1 or a2.

e

The smoke class declared for class B1ca cables must originate from the EN 50399 test (30 kW flame source).

f

The smoke class declared for class B2ca, Cca, Dca cables must originate from the EN 50399 test (20,5 kW flame source).

ClassTest method(s)Classification criteriaAdditional classification
Aca EN ISO 1716PCS ≤ 2,0 MJ/kga
B1ca

EN 50399 (30 kW flame source)

and

FS ≤ 1,75 m and

THR1200s ≤ 10 MJ and

Peak HRR ≤ 20 kW and

FIGRA ≤ 120 Ws– 1

Smoke productionb e and Flaming droplets/particlesc and Acidity (pH and conductivity)d
EN 60332-1-2H ≤ 425 mm
B2ca

EN 50399 (20,5 kW flame source)

and

FS ≤ 1,5 m; and

THR1200s ≤ 15 MJ; and

Peak HRR ≤ 30 kW; and

FIGRA ≤ 150 Ws– 1

Smoke productionb f and Flaming droplets/particlesc and Acidity (pH and conductivity)d
EN 60332-1-2H ≤ 425 mm
Cca

EN 50399 (20,5 kW flame source)

and

FS ≤ 2,0 m; and

THR1200s ≤ 30 MJ; and

Peak HRR ≤ 60 kW; and

FIGRA ≤ 300 Ws– 1

Smoke productionb f and Flaming droplets/particlesc and Acidity (pH and conductivity)d
EN 60332-1-2H ≤ 425 mm
Dca

EN 50399 (20,5 kW flame source)

and

THR1200s ≤ 70 MJ; and

Peak HRR ≤ 400 kW; and

FIGRA ≤ 1 300 Ws– 1

Smoke productionb f and Flaming droplets/particlesc and Acidity (pH and conductivity)d
EN 60332-1-2H ≤ 425 mm
Eca EN 60332-1-2H ≤ 425 mm
Fca EN 60332-1-2H > 425 mm
(2)

Commission Decision 2000/147/EC of 8 February 2000 implementing Council Directive 89/106/EEC as regards the classification of the reaction to fire performance of construction products (OJ L 50, 23.2.2000, p. 14).

(3)

The characteristics are defined with respect to the appropriate test method.

Back to top

Options/Help

Print Options

Close

Legislation is available in different versions:

Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.

Original (As adopted by EU): The original version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.

Close

See additional information alongside the content

Geographical Extent: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.

Show Timeline of Changes: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.

Close

Opening Options

Different options to open legislation in order to view more content on screen at once

Close

More Resources

Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as adopted version that was used for the EU Official Journal
  • lists of changes made by and/or affecting this legislation item
  • all formats of all associated documents
  • correction slips
  • links to related legislation and further information resources
Close

Timeline of Changes

This timeline shows the different versions taken from EUR-Lex before exit day and during the implementation period as well as any subsequent versions created after the implementation period as a result of changes made by UK legislation.

The dates for the EU versions are taken from the document dates on EUR-Lex and may not always coincide with when the changes came into force for the document.

For any versions created after the implementation period as a result of changes made by UK legislation the date will coincide with the earliest date on which the change (e.g an insertion, a repeal or a substitution) that was applied came into force. For further information see our guide to revised legislation on Understanding Legislation.

Close

More Resources

Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as adopted version that was used for the print copy
  • correction slips

Click 'View More' or select 'More Resources' tab for additional information including:

  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • links to related legislation and further information resources