Search Legislation

Commission Regulation (EC) No 278/2009 (repealed)Show full title

Commission Regulation (EC) No 278/2009 of 6 April 2009 implementing Directive 2005/32/EC of the European Parliament and of the Council with regard to ecodesign requirements for no-load condition electric power consumption and average active efficiency of external power supplies (Text with EEA relevance) (repealed)

 Help about what version

What Version

 Help about advanced features

Advanced Features

More Resources

 Help about UK-EU Regulation

Legislation originating from the EU

When the UK left the EU, legislation.gov.uk published EU legislation that had been published by the EU up to IP completion day (31 December 2020 11.00 p.m.). On legislation.gov.uk, these items of legislation are kept up-to-date with any amendments made by the UK since then.

Close

This item of legislation originated from the EU

Legislation.gov.uk publishes the UK version. EUR-Lex publishes the EU version. The EU Exit Web Archive holds a snapshot of EUR-Lex’s version from IP completion day (31 December 2020 11.00 p.m.).

Changes over time for: Commission Regulation (EC) No 278/2009 (repealed) (Annexes only)

 Help about opening options

Version Superseded: 01/04/2020

Status:

Point in time view as at 31/01/2020.

Changes to legislation:

There are outstanding changes not yet made to Commission Regulation (EC) No 278/2009 (repealed). Any changes that have already been made to the legislation appear in the content and are referenced with annotations. Help about Changes to Legislation

Close

Changes to Legislation

Changes and effects yet to be applied by the editorial team are only applicable when viewing the latest version or prospective version of legislation. They are therefore not accessible when viewing legislation as at a specific point in time. To view the ‘Changes to Legislation’ information for this provision return to the latest version view using the options provided in the ‘What Version’ box above.

ANNEX IU.K. ECODESIGN REQUIREMENTS

1.NO-LOAD POWER CONSUMPTION AND AVERAGE ACTIVE EFFICIENCYU.K.

(a) One year after this Regulation has come into force:U.K.

The no-load condition power consumption shall not exceed 0,50 W.

The average active efficiency shall be not less than:

  • 0,500 · PO, for PO < 1,0 W;

  • 0,090 · ln(PO) + 0,500, for 1,0 W ≤ PO ≤ 51,0 W;

  • 0,850, for PO > 51,0 W.

(b) Two years after this Regulation has come into force:U.K.

  • The no-load condition power consumption shall not exceed the following limits:

    AC-AC external power supplies, except low voltage external power suppliesAC-DC external power supplies except low voltage external power suppliesLow voltage external power supplies
    PO ≤ 51,0 W0,5 W0,3 W0,3 W
    PO > 51,0 W0,5 W0,5 Wn/a
  • The average active efficiency shall be not less than the following limits:

    AC-AC and AC-DC external power supplies, except low voltage external power suppliesLow voltage external power supplies
    PO ≤ 1,0 W0,480 · PO + 0,1400,497 · PO + 0,067
    1,0 W < PO ≤ 51,0 W0,063 · ln(PO) + 0,6220,075 · ln(PO) + 0,561
    PO > 51,0 W0,870,86

2.MEASUREMENTSU.K.

The no-load condition power consumption and the average active efficiency referred to in point 1 shall be established by a reliable, accurate and reproducible measurement procedure, which takes into account the generally recognised state of the art.

[ F1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .]

3.INFORMATION TO BE PROVIDED BY MANUFACTURERSU.K.

For the purposes of conformity assessment pursuant to Article 4, the technical documentation shall contain the following elements:

Reported quantityDescription
Root mean square (Rms) output current (mA)Measured at load conditions 1-4
Rms output voltage (V)
Active output power (W)
Rms input voltage (V)Measured at load conditions 1-5
Rms input power (W)
Total harmonic distortion (THD)
True power factor
Power consumed (W)Calculated at load condition 1-4, measured at load condition 5
EfficiencyCalculated at load conditions 1-4
Average efficiencyArithmetic average of efficiency at load conditions 1-4

The relevant load conditions are as follows:

Percentage of nameplate output current
Load condition 1100 % ± 2 %
Load condition 275 % ± 2 %
Load condition 350 % ± 2 %
Load condition 425 % ± 2 %
Load condition 50 % (no-load condition)

[F2ANNEX II U.K. Product compliance verification by market surveillance authorities

The verification tolerances defined in this Annex relate only to the verification of the measured parameters by Member State authorities and shall not be used by the manufacturer or importer as an allowed tolerance to establish the values in the technical documentation or in interpreting these values with a view to achieving compliance or to communicate better performance by any means.

When verifying the compliance of a product model with the requirements laid down in this Regulation pursuant to Article 3(2) of Directive 2009/125/EC, for the requirements referred to in this Annex, the authorities of the Member States shall apply the following procedure:

(1)

The Member State authorities shall verify one single unit of the model.

(2)

The model shall be considered to comply with the applicable requirements if:

(a)

the values given in the technical documentation pursuant to point 2 of Annex IV to Directive 2009/125/EC (declared values), and, where applicable, the values used to calculate these values, are not more favourable for the manufacturer or importer than the results of the corresponding measurements carried out pursuant to paragraph (g) thereof; and

(b)

the declared values meet any requirements laid down in this Regulation, and any required product information published by the manufacturer or importer does not contain values that are more favourable for the manufacturer or importer than the declared values; and

(c)

when the Member State authorities test the unit of the model, the determined values (the values of the relevant parameters as measured in testing and the values calculated from these measurements) comply with the respective verification tolerances as given in the table below.

(3)

If the results referred to in point 2(a) or (b) are not achieved, the model shall be considered not to comply with this Regulation.

(4)

If the result referred to in point 2(c) is not achieved, the Member State authorities shall select three additional units of the same model for testing.

(5)

The model shall be considered to comply with the applicable requirements if, for these three units, the arithmetical mean of the determined values complies with the respective verification tolerances given in the table below.

(6)

If the result referred to in point 5 is not achieved, the model shall be considered not to comply with this Regulation.

(7)

The Member State authorities shall provide all relevant information to the authorities of the other Member States and to the Commission without delay after a decision being taken on the non-compliance of the model according to points 3 and 6.

The Member State authorities shall use the measurement and calculation methods set out in Annex I.

The Member State authorities shall only apply the verification tolerances that are set out in the table below and shall only use the procedure described in points 1 to 7 for the requirements referred to in this Annex. No other tolerances, such as those set out in harmonised standards or in any other measurement method, shall be applied.

Verification tolerances

Parameters Verification tolerances
No-load condition The determined value shall not exceed the declared value by more than 0,10 W.
Arithmetical mean of efficiency at load conditions 1-4 as defined in Annex I The determined value shall not be lower than the declared value by more than 5 %.]

ANNEX IIIU.K. INDICATIVE BENCHMARKS REFERRED TO IN ARTICLE 6

(a) No-load condition U.K.

The lowest available no-load condition power consumption of external power supplies can be approximated by:

  • 0,1 W or less, for PO ≤ 90 W,

  • 0,2 W or less, for 90 W < PO ≤ 150 W,

  • 0,4 W or less, for 150 W < PO ≤ 180 W,

  • 0,5 W or less, for PO > 180 W.

(b) Average active efficiency U.K.

The best available active average efficiency of external power supplies according to most recent available data (status January 2008) can be approximated by:

  • 0,090 · ln (PO) + 0,680, for 1,0 W ≤ PO ≤ 10,0 W,

  • 0,890, for PO > 10,0 W.

Back to top

Options/Help

Print Options

Close

Legislation is available in different versions:

Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.

Original (As adopted by EU): The original version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.

Point in Time: This becomes available after navigating to view revised legislation as it stood at a certain point in time via Advanced Features > Show Timeline of Changes or via a point in time advanced search.

Close

See additional information alongside the content

Geographical Extent: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.

Show Timeline of Changes: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.

Close

Opening Options

Different options to open legislation in order to view more content on screen at once

Close

More Resources

Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as adopted version that was used for the EU Official Journal
  • lists of changes made by and/or affecting this legislation item
  • all formats of all associated documents
  • correction slips
  • links to related legislation and further information resources
Close

Timeline of Changes

This timeline shows the different versions taken from EUR-Lex before exit day and during the implementation period as well as any subsequent versions created after the implementation period as a result of changes made by UK legislation.

The dates for the EU versions are taken from the document dates on EUR-Lex and may not always coincide with when the changes came into force for the document.

For any versions created after the implementation period as a result of changes made by UK legislation the date will coincide with the earliest date on which the change (e.g an insertion, a repeal or a substitution) that was applied came into force. For further information see our guide to revised legislation on Understanding Legislation.

Close

More Resources

Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as adopted version that was used for the print copy
  • correction slips

Click 'View More' or select 'More Resources' tab for additional information including:

  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • links to related legislation and further information resources