Search Legislation

First Commission Directive of 25 October 1985 on methods of analysis for edible caseins and caseinates (85/503/EEC)

 Help about what version

What Version

Close

This is a legislation item that originated from the EU

After exit day there will be three versions of this legislation to consult for different purposes. The legislation.gov.uk version is the version that applies in the UK. The EU Version currently on EUR-lex is the version that currently applies in the EU i.e you may need this if you operate a business in the EU.

The web archive version is the official version of this legislation item as it stood on exit day before being published to legislation.gov.uk and any subsequent UK changes and effects applied. The web archive also captured associated case law and other language formats from EUR-Lex.

Status:

EU Directives are being published on this site to aid cross referencing from UK legislation. After IP completion day (31 December 2020 11pm) no further amendments will be applied to this version.

  1. Introductory Text

  2. Article 1.Member States shall take all measures necessary to ensure that...

  3. Article 2.Member States shall bring into force the laws, regulations and...

  4. Article 3.This Directive is addressed to the Member States.

  5. Signature

    1. ANNEX I

      SCOPE OF THE FIRST COMMUNITY METHODS OF ANALYSIS DIRECTIVE FOR EDIBLE CASEINS AND CASEINATES

      1. General Provisions Determination of moisture in: acid caseins using method...

    2. ANNEX II

      METHODS OF ANALYSIS RELATING TO THE COMPOSITION OF EDIBLE CASEINS AND CASEINATES

      1. GENERAL PROVISIONS

        1. 1. PREPARATION OF THE ANALYSIS SAMPLE

          1. 1.1. General

          2. 1.2. Preparation of the sample for analysis in the laboratory

            1. 1.2.1. Thoroughly mix and break down any lumps, etc., in the...

            2. 1.2.2. Transfer a representative portion of the sample, i.e. about 50...

            3. 1.2.3. If the 50 gram portion completely or almost completely passes...

            4. 1.2.4. Otherwise, grind the 50 gram portion, using the grinding device...

            5. 1.2.5. After the test sample has been prepared, any determination should...

          3. 1.3. Containers

        2. 2. REAGENTS

          1. 2.1. Water

            1. 2.1.1. Wherever mention is made to water for solution, dilution or...

            2. 2.1.2. Wherever reference is made to ‘solution’ or ‘dilution’ without further...

          2. 2.2. Chemicals

        3. 3. EQUIPMENT

          1. 3.1. Lists of equipment

          2. 3.2. Analytical balance

          3. 3.3. Test sieve

          4. 3.4. Grinding device

        4. 4. EXPRESSION OF RESULTS

          1. 4.1. Results

          2. 4.2. Calculation of percentage

        5. 5. TEST REPORT

      2. METHOD 1

        1. DETERMINATION OF MOISTURE CONTENT

          1. 1. SCOPE AND FIELD OF APPLICATION

          2. 2. DEFINITION

          3. 3. PRINCIPLE

          4. 4. APPARATUS

            1. 4.1. Analytical balance

              1. 4.2. Dishes, flat-bottomed and of material non-corrodible under the conditions of...

              2. 4.3. Atmospheric pressure drying oven, well ventilated, thermostatically controlled with temperature...

              3. 4.4. Desiccator, containing freshly activated silica gel with a water content...

              4. 4.5. Suitable device for handling dishes, e.g. laboratory tongs.

          5. 5. PROCEDURE

            1. 5.1. Preparation of the test sample

            2. 5.2. Preparation of the dish

              1. 5.2.1. Heat the uncovered dish and its lid (4.2) in the...

              2. 5.2.2. Place the lid on the dish, transfer the covered dish...

            3. 5.3. Test portion

            4. 5.4. Determination

              1. 5.4.1. Uncover the dish and place it with its lid in...

              2. 5.4.2. Replace the lid on the dish, transfer to the desiccator,...

              3. 5.4.3. Uncover the dish and heat it again, with its lid,...

              4. 5.4.4. If the mass obtained in 5.4.3 is less than the...

          6. 6. EXPRESSION OF RESULTS

            1. 6.1. Method of calculation

            2. 6.2. Repeatability

      3. METHOD 2

        1. DETERMINATION OF PROTEIN CONTENT

          1. 1. SCOPE AND FIELD OF APPLICATION

          2. 2. DEFINITION

          3. 3. PRINCIPLE

          4. 4. REAGENTS

            1. 4.1. Sulphuric acid, concentrated, S2O 1,84 g/ml.

            2. 4.2. Potassium sulphate, anhydrous (K2SO4).

            3. 4.3. Copper (II) sulphate pentahydrate (CuSO45H2O).

            4. 4.4. Sucrose (C12H22O11).

            5. 4.5. Boric acid, 40-g/l solution.

            6. 4.6. Sodium hydroxide, concentrated aqueous solution 30 % (m/m), carbonate free....

            7. 4.7. Hydrochloric acid, 0,1 mol/1.

            8. 4.8. Mixed indicator. Mix equal volumes of a 2 g/1 solution...

          5. 5. APPARATUS

            1. 5.1. Analytical balance

              1. 5.2. Kjeldahl flask, 500 ml capacity.

              2. 5.3. Digestion apparatus to hold the Kjeldahl flask (5.2) in an...

              3. 5.4. Condenser with straight inner tube.

              4. 5.5. Outlet tube with safety bulb connected to the lower end...

              5. 5.6. Splash-head connected to the Kjeldahl flask (5.2) and to the...

              6. 5.7. Conical flask, 500 ml capacity.

              7. 5.8. Graduated cylinders, 50 ml and 100 ml capacity.

              8. 5.9. Burette, 50 ml capacity, graduated in 0,1 ml.

            2. 5.10. Boiling aids:

              1. 5.10.1. For the digestion: small pieces of hard porcelain, or glass...

              2. 5.10.2. For the distillation; freshly calcined pieces of pumice.

          6. 6. PROCEDURE

            1. 6.1. Preparation of the test sample

            2. 6.2. Test for presence of ammoniacal nitrogen

            3. 6.3. Blank test

            4. 6.4. Test portion

            5. 6.5. Determination

              1. 6.5.1. Transfer to the flask a few pieces of porcelain or...

              2. 6.5.2. Transfer into the conical flask (5.7) 50 ml of the...

              3. 6.5.3. Titrate the distillate in the conical flask, using the standard...

          7. 7. EXPRESSION OF RESULTS

            1. 7.1. Formula and method of calculation

            2. 7.2. Repeatability

      4. METHOD 3

        1. DETERMINATION OF TITRATABLE ACIDITY

          1. 1. SCOPE AND FIELD OF APPLICATION

          2. 2. DEFINITION

          3. 3. PRINCIPLE

          4. 4. REAGENTS

            1. 4.1. Sodium hydroxide solution: 0,1 Mol/1.

            2. 4.2. Phenolphtalein indicator solution, 10 g/1 in ethanol (95 % V/V)...

          5. 5. APPARATUS

            1. 5.1. Analytical balance

              1. 5.2. Conical flask, 500 ml capacity, with ground neck and fitted...

              2. 5.3. One-mark pipette, 100 ml capacity.

              3. 5.4. Pipette, suitable for measuring 0,5 ml of indicator solution (4.2)....

              4. 5.5. Conical flask, 250 ml capacity.

              5. 5.6. Measuring cylinder, 250 ml capacity.

              6. 5.7. Burette, graduated in 0,1 ml.

              7. 5.8. Water bath, capable of being controlled at a temperature of...

              8. 5.9. Appropriate filter

          6. 6. PROCEDURE

            1. 6.1. Preparation of the test sample

            2. 6.2. Test portion

            3. 6.3. Determination

          7. 7. EXPRESSION OF RESULTS

            1. 7.1. Formula and method of calculation

            2. 7.2. Repeatability

      5. METHOD 4

        1. DETERMINATION OF ASH (including P2O5)

          1. 1. SCOPE AND FIELD OF APPLICATION

          2. 2. DEFINITION

          3. 3. PRINCIPLE

          4. 4. REAGENTS

            1. 4.1. Magnesium acetate tetrahydrate solution, 120 g/1. Dissolve 120 grams of...

          5. 5. APPARATUS

            1. 5.1. Analytical balance

            2. 5.2. One-mark pipette, 5 ml.

            3. 5.3. Silica or platinum dishes, about 70 mm diameter and 25...

            4. 5.4. Drying oven, capable of being controlled at 102 oC ±...

            5. 5.5. Electrical furnace, capable of being controlled at 825 oC ±...

            6. 5.6. Boiling water bath

            7. 5.7. Desiccator containing freshly activated silica gel with a water content...

          6. 6. PROCEDURE

            1. 6.1. Preparation of the test sample

            2. 6.2. Preparation of the dishes

            3. 6.3. Test portion

            4. 6.4. Determination

          7. 7. EXPRESSION OF RESULTS

            1. 7.1. Method of calculation

            2. 7.2. Repeatability

      6. METHOD 5

        1. DETERMINATION OF ASH (including P2O5)

          1. 1. SCOPE AND FIELD OF APPLICATION

          2. 2. DEFINITION

          3. 3. PRINCIPLE

          4. 4. APPARATUS

            1. 4.1. Analytical balance

            2. 4.2. Silica or platinum dish, about 70 mm diameter and 25...

            3. 4.3. Electrical furnace with air circulation, capable of being controlled at...

            4. 4.4. Desiccator, containing freshly activated silica gel with a water content...

          5. 5. PROCEDURE

            1. 5.1. Preparation of the test sample

            2. 5.2. Preparation of the dish

            3. 5.3. Test portion

            4. 5.4. Determination

          6. 6. EXPRESSION OF RESULTS

            1. 6.1. Method of calculation and formula

            2. 6.2. Repeatability

      7. METHOD 6

        1. DETERMINATION OF pH

          1. 1. SCOPE AND FIELD OF APPLICATION

          2. 2. DEFINITION

          3. 3. PRINCIPLE

          4. 4. REAGENTS

            1. 4.1. Buffer solutions, for calibration of the pH meter (5.2)

          5. 5. APPARATUS

            1. 5.1. Balance, accuracy 0,1 grams.

            2. 5.2. pH meter, minimum sensitivity 0,05 pH unit, with a suitably...

            3. 5.3. Thermometer, accuracy 0,5 oC.

            4. 5.4. Conical flask, capacity 100 ml, fitted with a ground glass...

            5. 5.5. Beaker, capacity 50 ml.

            6. 5.6. Mixer

              1. 5.7. Beaker, for the mixer (5.6) of at least 250 ml...

          6. 6. PROCEDURE

            1. 6.1. Preparation of the test sample

            2. 6.2. Determination

              1. 6.2.1. Calibration of pH meter

                1. NOTES

                  1. 1. The calibration should be carried out while the flasks are...

                  2. 2. If a series of samples is being tested, check the...

              2. 6.2.2. Preparation of the test solution

              3. 6.2.3. Measurement of pH

                1. 6.2.3.1. Pour about 20 ml of the solution into the beaker...

                2. 6.2.3.2. Measure the pH.

          7. 7. EXPRESSION OF RESULTS

            1. 7.1. Recording of pH

            2. 7.2. Repeatability

Back to top

Options/Help

Print Options

Close

Legislation is available in different versions:

Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.

Original (As adopted by EU): The original version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.

Point in Time: This becomes available after navigating to view revised legislation as it stood at a certain point in time via Advanced Features > Show Timeline of Changes or via a point in time advanced search.

Close

Opening Options

Different options to open legislation in order to view more content on screen at once

Close

More Resources

Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as adopted version that was used for the EU Official Journal
  • lists of changes made by and/or affecting this legislation item
  • all formats of all associated documents
  • correction slips
  • links to related legislation and further information resources
Close

Timeline of Changes

This timeline shows the different versions taken from EUR-Lex before exit day and during the implementation period as well as any subsequent versions created after the implementation period as a result of changes made by UK legislation.

The dates for the EU versions are taken from the document dates on EUR-Lex and may not always coincide with when the changes came into force for the document.

For any versions created after the implementation period as a result of changes made by UK legislation the date will coincide with the earliest date on which the change (e.g an insertion, a repeal or a substitution) that was applied came into force. For further information see our guide to revised legislation on Understanding Legislation.

Close

More Resources

Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as adopted version that was used for the print copy
  • correction slips

Click 'View More' or select 'More Resources' tab for additional information including:

  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • links to related legislation and further information resources