Commission Regulation (EC) No 627/2006 of 21 April 2006 implementing Regulation (EC) No 2065/2003 of the European Parliament and of the Council as regards quality criteria for validated analytical methods for sampling, identification and characterisation of primary smoke products
Pan adawodd y DU yr UE, cyhoeddodd legislation.gov.uk ddeddfwriaeth yr UE a gyhoeddwyd gan yr UE hyd at ddiwrnod cwblhau’r cyfnod gweithredu (31 Rhagfyr 2020 11.00 p.m.). Ar legislation.gov.uk, mae'r eitemau hyn o ddeddfwriaeth yn cael eu diweddaru'n gyson ag unrhyw ddiwygiadau a wnaed gan y DU ers hynny.
Mae legislation.gov.uk yn cyhoeddi fersiwn y DU. Mae EUR-Lex yn cyhoeddi fersiwn yr UE. Mae Archif Gwe Ymadael â’r UE yn rhoi cipolwg ar fersiwn EUR-Lex o ddiwrnod cwblhau’r cyfnod gweithredu (31 Rhagfyr 2020 11.00 p.m.).
There are currently no known outstanding effects by UK legislation for Commission Regulation (EC) No 627/2006.![]()
Revised legislation carried on this site may not be fully up to date. At the current time any known changes or effects made by subsequent legislation have been applied to the text of the legislation you are viewing by the editorial team. Please see ‘Frequently Asked Questions’ for details regarding the timescales for which new effects are identified and recorded on this site.
THE COMMISSION OF THE EUROPEAN COMMUNITIES,
Having regard to the Treaty establishing the European Community,
Having regard to Regulation (EC) No 2065/2003 of the European Parliament and the Council of 10 November 2003 on smoke flavourings used or intended for use in or on foods(1) and in particular Article 17(3) thereof,
Whereas:
(1) Regulation (EC) No 2065/2003 lays down provisions for the establishment of a list of primary products authorised for use as such in or on foods and for the production of smoke flavourings for use in or on foods within the Community. This list shall, among other things, contain a clear description and characterisation of each primary product.
(2) Detailed information about the qualitative and quantitative chemical composition of the primary product is necessary for the scientific evaluation. The portions which have not been identified, i.e. the amount of substances whose chemical structure is not known, should be as small as possible.
(3) It is therefore necessary to establish minimum performance criteria, in this context referred to as quality criteria, to which the method of analysis shall comply in order to ensure that laboratories use methods with the necessary level of performance.
(4) Smoked foods in general give rise to health concerns, especially with respect to the possible presence of polycyclic aromatic hydrocarbons (PAHs).
(5) The person who intends to place primary products on the market should submit all the information necessary for the safety assessment. This information should contain a proposed validated method for sampling, identification and characterisation of the primary product.
(6) Regulation (EC) No 882/2004 of the European Parliament and the Council of 29 April 2004 on official controls performed to ensure the verification of compliance with feed and food law, animal health and animal welfare rules(2), lays down general requirements for methods of sampling and analysis.
(7) The Scientific Committee on Food (SCF) named 15 PAHs as potentially genotoxic and carcinogenic to humans in an opinion on the risks to human health of PAH in food, expressed on 4 December 2002(3). They represent a priority group in the assessment of the risk of long-term adverse health effects following dietary intake of PAHs. Their presence in primary products should — as a consequence — be analysed.
(8) The Institute for Reference Materials and Measurements (IRMM) of the Commission Directorate General Joint Research Centre carried out collaborative studies for analysing the chemical composition of primary products and for quantifying the concentration of the 15 PAHs therein. The results of these trials are in part published in the Report on the Collaborative Trial for Validation of two Methods for the Quantification of Polycyclic Aromatic Hydrocarbons in Primary Smoke Condensates(4).
(9) To describe the precision of the method the repeatability standard deviation as defined in ISO 5725-1(5) is required. It should be estimated using data from a single-laboratory validation exercise giving Si as described in the Harmonized Guidelines for Single-Laboratory Validation of Methods of Analysis(6) or a collaborative trial giving Sr and SR as described in the Protocol for the design, conduct and interpretation of method-performance studies(7).
(10) A full validation of methods to analyse the composition of primary products, with a maximum of compounds identified, is not achievable. The high number of analytes gives rise to incalculable amount of work which is impractical. If however mass spectrometry is used for the detection of compounds, the resulting mass spectra can be compared to published data(8) or to mass spectral libraries and a tentative identification of the compounds can be achieved.
(11) Based on the results obtained in the inter-laboratory validation study on PAHs and following Commission Decision 2002/657/EC(9), minimum quality criteria for any suitable analytical method for determination of PAHs in all primary products have been proposed.
(12) Following the recommendation given in the ISO, IUPAC, and AOAC International Harmonized Guidelines for the Use of Recovery Information in Analytical Measurement, the analytical results should be corrected for recovery.
(13) The European Food Safety Authority has given scientific and technical assistance for the elaboration of the quality criteria for validated methods for identification and characterisation of primary smoke products laid down in this regulation.
(14) The quality criteria can be adapted, to take into account advances in scientific and technological knowledge.
(15) The measures provided for in this Regulation are in accordance with the opinion of the Standing Committee on the Food Chain and Animal Health,
HAS ADOPTED THIS REGULATION:
The quality criteria for validated analytical methods for sampling, identification and characterisation of primary smoke products, as referred to in point 4 of Annex II to Regulation (EC) No 2065/2003, shall be as set out in the Annex to this Regulation.
This Regulation shall enter into force on the twentieth day following that of its publication in the Official Journal of the European Union.
F1...
Done at Brussels, 21 April 2006.
For the Commission
Markos Kyprianou
Member of the Commission
Textual Amendments
F1Words in Signature omitted (31.12.2020) by virtue of The Food Additives, Flavourings, Enzymes and Extraction Solvents (Amendment etc.) (EU Exit) Regulations 2019 (S.I. 2019/860), regs. 1, 35; 2020 c. 1, Sch. 5 para. 1(1)
The basic requirement is to obtain a representative and homogeneous laboratory sample.
The analyst shall ensure that samples do not become contaminated during sample preparation. Containers have to be rinsed with high purity acetone or hexane (p.A., HLPC grade or equivalent) before use to minimise the risk of contamination. Wherever possible, apparatus coming into contact with the sample shall be made of inert materials e.g. glass or polished stainless steel. Plastics such as polypropylene are to be avoided, because the analyte can adsorb onto these materials.
All of the sample material received by the laboratory is to be used for the preparation of test material. Only very finely homogenised samples give reproducible results.
There are many satisfactory specific sample preparation procedures which may be used.
For the purpose of this Annex the following definitions shall apply:
:
The mass of the material after abstraction of the solvent, which normally is water.
:
The part of the solvent free mass, which is volatile and analysable by gas chromatography.
:
Results of a descriptive analysis, which identifies substances present in the primary product.
:
Identification of the major physical-chemical fractions and quantification and identification of the chemical constituents.
:
Limit of Quantification
:
Limit of Detection
:
The single-laboratory standard deviation, calculated from results generated under repeatability conditions as defined in ISO standard 5725-1(10) (= repeatability standard deviation estimated in a single laboratory approach according to the Harmonized Guidelines for Single-Laboratory Validation of Methods of Analysis(11)).
:
The average within laboratory standard deviation, calculated from results generated under repeatability conditions as defined in ISO standard 5725-1(10) in a collaborative trial with a minimum of eight laboratories conducted according to the Protocol for the Design, Conduct and Interpretation of Method-Performance Studies(12).
:
The between laboratory standard deviation, calculated from results under reproducibility conditions as defined in ISO standard 5725-1(10) and according to the Protocol for the Design, Conduct and Interpretation of Method-Performance Studies(12).
:
Relative single-laboratory repeatability standard deviation (Si expressed in percent of the measured value),
:
Relative average repeatability standard deviation (Sr expressed in percent of the measured value),
:
Relative reproducibility standard deviation (SR expressed in percent of the measured value).
Without prejudice to Article 11 of Regulation (EC) No 882/2004, the validated method for identification and characterisation to be selected by the laboratory shall comply with the quality criteria indicated in Tables 1 and 2.
Quality criteria for methods for identification and quantification of chemical constituents in the solvent free mass and the volatile fraction of primary products
| Parameter | Value/Comment |
|---|---|
| Solvent free mass | At least 50 % by mass shall be identified and quantified |
| Volatile fraction | At least 80 % by mass shall be identified and quantified |
Minimum method quality criteria for analysing Polycyclic Aromatic Hydrocarbons (PAHs)
| a Over the whole analytical range. | |||||||
| b The RSDi, RSDr and RSDR values are relatively high due to the low stability of the analytes in primary smoke condensate. | |||||||
| c Corrected for recovery. | |||||||
| Analyte(s) PAH | RSDi a | RSDr a | RSDR a | LODc | LOQc | Analytical rangec | Recoverya |
|---|---|---|---|---|---|---|---|
| % | % | % | μg/kg | μg/kg | μg/kg | % | |
| benzo[a]pyrene | 20 | 20 | 40 | 1,5 | 5,0 | 5,0-15 | 75-110 |
| benzo[a]anthracene | 20 | 20 | 40 | 3,0 | 10 | 10-30 | 75-110 |
| cyclopenta[cd]pyreneb dibenzo[a,e]pyreneb dibenzo[a,i]pyreneb dibenzo[a,h]pyreneb | 35 | 35 | 70 | 5,0 | 15 | 15-45 | 50-110 |
| chrysene 5-methylchrysene benzo[b]fluoranthene benzo[j]fluoranthene benzo[k]fluoranthene indeno[123-cd]pyrene dibenzo[a,h]anthracene benzo[ghi]perylene dibenzo[a,l]pyrene | 25 | 25 | 50 | 5,0 | 15 | 10-30 | 60-110 |
SCF/CS/CNTM/PAH/29 Final, 4 December 2002.
EU-Report LA-NA-21679-EN-C, ISBN 92-894-9629-0.
ISO5725-1: Accuracy (trueness and precision) of measurement methods and results — Part 1: General principles and definitions. 1994: Geneva.
Thompson, M., S.L.R. Ellison, and R. Wood, Harmonized Guidelines for Single-Laboratory Validation of Methods of Analysis. Pure and Applied Chemistry, 2002. 74(5): pp. 835-855.
Horwitz, W., Protocol for the design, conduct and interpretation of method-performance studies. Pure and Applied Chemistry, 1995. 67(2): pp. 331-343.
http://www.irmm.jrc.be/html/activities/intense_sweeteners_and_smoke_flavourings/liquid_smoke_components.xls
Faix, O., et al., Holz als Roh- & Werkstoff, 1991. 49: pp. 213-219.
Faix, O., et al., Holz als Roh- & Werkstoff, 1991. 49: pp. 299-304.
Faix, O., D. Meier, and I. Fortmann, Holz als Roh- & Werkstoff, 1990. 48: pp. 281-285.
Faix, O., D. Meier, and I. Fortmann, Holz als Roh- & Werkstoff, 1990. 48: pp. 351-354.
OJ L 221, 17.8.2002, p. 8. Decision as last amended by Decision 2004/25/EC (OJ L 6, 10.1.2004, p. 38).
ISO 5725-1: Accuracy (trueness and precision) of measurement methods and results — Part 1: General principles and definitions. Geneva, 1994.
Thompson, M., S.L.R. Ellison, and R. Wood, Harmonized Guidelines for Single-Laboratory Validation of Methods of Analysis. Pure and Applied Chemistry, 2002. 74(5): pp. 835-855.
Horwitz, W., Protocol for the design, conduct and interpretation of method-performance studies. Pure and Applied Chemistry, 1995. 67(2): pp. 331-343.
Y Diweddaraf sydd Ar Gael (diwygiedig):Y fersiwn ddiweddaraf sydd ar gael o’r ddeddfwriaeth yn cynnwys newidiadau a wnaed gan ddeddfwriaeth ddilynol ac wedi eu gweithredu gan ein tîm golygyddol. Gellir gweld y newidiadau nad ydym wedi eu gweithredu i’r testun eto yn yr ardal ‘Newidiadau i Ddeddfwriaeth’.
Gwreiddiol (Fel y’i mabwysiadwyd gan yr UE): Mae'r wreiddiol version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.
Rhychwant ddaearyddol: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.
Dangos Llinell Amser Newidiadau: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.
Gallwch wneud defnydd o ddogfennau atodol hanfodol a gwybodaeth ar gyfer yr eitem ddeddfwriaeth o’r tab hwn. Yn ddibynnol ar yr eitem ddeddfwriaeth sydd i’w gweld, gallai hyn gynnwys:
Mae’r llinell amser yma yn dangos y fersiynau gwahanol a gymerwyd o EUR-Lex yn ogystal ag unrhyw fersiynau dilynol a grëwyd ar ôl y diwrnod ymadael o ganlyniad i newidiadau a wnaed gan ddeddfwriaeth y Deyrnas Unedig.
Cymerir dyddiadau fersiynau’r UE o ddyddiadau’r dogfennau ar EUR-Lex ac efallai na fyddant yn cyfateb â’r adeg pan ddaeth y newidiadau i rym ar gyfer y ddogfen.
Ar gyfer unrhyw fersiynau a grëwyd ar ôl y diwrnod ymadael o ganlyniad i newidiadau a wnaed gan ddeddfwriaeth y Deyrnas Unedig, bydd y dyddiad yn cyd-fynd â’r dyddiad cynharaf y daeth y newid (e.e. ychwanegiad, diddymiad neu gyfnewidiad) a weithredwyd i rym. Am ragor o wybodaeth gweler ein canllaw i ddeddfwriaeth ddiwygiedig ar Ddeall Deddfwriaeth.
Defnyddiwch y ddewislen hon i agor dogfennau hanfodol sy’n cyd-fynd â’r ddeddfwriaeth a gwybodaeth am yr eitem hon o ddeddfwriaeth. Gan ddibynnu ar yr eitem o ddeddfwriaeth sy’n cael ei gweld gall hyn gynnwys:
liciwch ‘Gweld Mwy’ neu ddewis ‘Rhagor o Adnoddau’ am wybodaeth ychwanegol gan gynnwys