1. The data-quality objectives set out in the following table, for the required accuracy of assessment methods, of minimum time coverage and of data capture of measurement are laid down to guide quality assurance programmes—
Sulphur dioxide, nitrogen dioxide and oxides of nitrogen | Lead, PM2.5 and PM10 | |
---|---|---|
Continuous measurement | ||
Accuracy | 15% | 25% |
Minimum data capture | 90% | 90% |
Indicative measurement | ||
Accuracy | 25% | 50% |
Minimum data capture | 90% | 90% |
Minimum time coverage | 14% (One measurement a week at random, evenly distributed over the year, or eight weeks evenly distributed over the year) | 14% (One measurement a week at random, evenly distributed over the year, or eight weeks evenly distributed over the year) |
Modelling | ||
Accuracy | ||
Hourly averages | 50%–60% | |
Daily averages | 50% | |
Annual averages | 30% | 50% |
Objective estimation | ||
Accuracy | 75% | 100% |
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: