- Latest available (Revised)
- Original (As made)
This is the original version (as it was originally made). This item of legislation is currently only available in its original format.
5. When carrying out a migration test of a plastic material or article which is intended for use in a microwave oven, if the appropriate time and temperature is selected from the Table to this Part, either a conventional oven or a microwave oven may be used.
6. Where the carrying out of a migration test under contact conditions specified in the Table to this Part causes any physical or other change in the test specimen which does not occur under the worst foreseeable conditions of use of the plastic material or article being tested the migration test shall be carried out in the worst foreseeable conditions of use in which such physical or other change does not occur.
7. Where, in actual use, the plastic material or article being tested is intended to be used for periods of less than 15 minutes at any temperature of not less than 70°C and not more than 100°C and such use is indicated by appropriate labelling or instructions no test other than for 2 hours at 70°C shall be carried out on the plastic material or article unless the plastic material or article is also intended to be used for storage at room temperature in which case no further test other than for 10 days test at 40°C shall be carried out.
8. The Table to this Part shall be read with the notes to it.
Conditions of contact in worst foreseeable use | Test conditions |
---|---|
Contact time | Test time |
(1) The period of time which represents the worst foreseeable conditions of contact. | |
t ≤ 5 minutes | (1) |
5 minutes < t ≤ 0·5 hours | 0·5 hours |
0·5 hours < t ≤ 1 hour | 1 hour |
1 hour < t ≤ 2 hours | 2 hours |
2 hours < t ≤ 4 hours | 4 hours |
4 hours < t ≤ 24 hours | 24 hours |
t > 24 hours | 10 days |
Contact temperature | Test temperature |
---|---|
(2) This temperature shall be used only for simulant D. For simulant A, B or C the test may be replaced by a test at 100°C or at reflux temperature for a duration of four times the time selected in accordance with paragraph 1 of this Part. | |
T ≤ 5°C | 5°C |
5°C < T ≤ 20°C | 20°C |
20°C < T ≤ 40°C | 40°C |
40°C < T ≤ 70°C | 70°C |
70°C < T ≤ 100°C | 100°C or reflux temperature |
100°C < T ≤ 121°C | 121°C(2) |
121°C < T ≤ 130°C | 130°C(2) |
130°C < T ≤ 150°C | 150°C(2) |
T > 150°C | 175°C(2) |
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include: