Directive 2003/97/EC of the European Parliament and of the Council of 10 November 2003 on the approximation of the laws of the Member States relating to the type-approval of devices for indirect vision and of vehicles equipped with these devices, amending Directive 70/156/EEC and repealing Directive 71/127/EEC (Text with EEA relevance) (repealed)

 Help about what version

What Version

 Help about advanced features

Advanced Features

Close

This is a legislation item that originated from the EU

After exit day there will be three versions of this legislation to consult for different purposes. The legislation.gov.uk version is the version that applies in the UK. The EU Version currently on EUR-lex is the version that currently applies in the EU i.e you may need this if you operate a business in the EU.

The web archive version is the official version of this legislation item as it stood on exit day before being published to legislation.gov.uk and any subsequent UK changes and effects applied. The web archive also captured associated case law and other language formats from EUR-Lex.

Status:

EU Directives are being published on this site to aid cross referencing from UK legislation. After IP completion day (31 December 2020 11pm) no further amendments will be applied to this version.

Appendix 2

Test method for determining reflectivity

1.DEFINITIONSU.K.

1.1.CIE standard illuminate A(1): Colorimetric illuminate, respecting the full radiator at T68 = 2 855,6 K.U.K.

1.2.CIE standard source A(1): Gas-filled tungsten filament lamp operating at a correlated colour temperature of T68= 2 855,6 K.U.K.

1.3.CIE 1931 standard colorimetric observer(1): Receptor of radiation whose colorimetric characteristics correspond to the spectral tristimulus values (λ), (λ), (λ) (see table).U.K.

1.4.CIE spectral tristimulus values(1): Tristimulus values of the spectral components of an equi-energy spectrum in the CIE (XYZ) system.U.K.

1.5.Photopic vision(1): Vision by the normal eye when it is adapted to levels of luminance of at least several cd/m2.U.K.

2.APPARATUSU.K.

2.1.GeneralU.K.

The apparatus shall consist of a light source, a holder for the test sample, a receiver unit with a photodetector and an indicating meter (see Figure 4), and means of eliminating the effects of extraneous light.

The receiver may incorporate a light-integrating sphere to facilitate measuring the reflectance of non-flat (convex) mirrors (see Figure 5).

2.2.Spectral characteristics of light source and receiverU.K.

The light source shall consist of a CIE standard source A and associated optics to provide a near-collimated light beam. A voltage stabiliser is recommended in order to maintain a fixed lamp voltage during instrument operation.

The receiver shall have a photodetector with a spectral response proportional to the photopic luminosity function of the CIE (1931) standard colorimetric observer (see table). Any other combination of illuminate-filter-receptor giving the overall equivalent of CIE standard illuminate A and photopic vision may be used. When an integrating sphere is used in the receiver, the interior surface of the sphere shall be coated with a matt (diffusive) spectrally non-selective white coating.

2.3.Geometrical conditionsU.K.

The angle of the incident beam (θ) should preferably be 0,44 ± 0,09 rad (25 ± 5 °) from the perpendicular to the test surface and shall not exceed the upper limit of the tolerance (i.e. 0,53 rad or 30 °). The axis of the receptor shall make an angle (θ) with this perpendicular equal to that of the incident beam (see Figure 4). The incident beam upon arrival at the test surface shall have a diameter of not less than 13 mm (0,5 in.). The reflected beam shall not be wider than the sensitive area of the photodetector, shall not cover less than 50 % of such area, and as nearly as possible shall cover the same area segment as used during instrument calibration.

When an integrating sphere is used in the receiver section, the sphere shall have a minimum diameter of 127 mm (5 in.). The sample and incident beam apertures in the sphere wall shall be of such a size as to admit the entire incident and reflected light beams. The photodetector shall be so located as not to receive direct light from either the incident or the reflected beam.

2.4.Electrical characteristics of the photodetector-indicator unitU.K.

The photodetector output as read on the indicating meter shall be a linear function of the light intensity of the photosensitive area. Means (electrical and/or optical) shall be provided to facilitate zeroing and calibration adjustments. Such means shall not affect the linearity or the spectral characteristics of the instrument. The accuracy of the receptor-indicator unit shall be within ± 2 % of full scale, or ± 10 % of the magnitude of the reading, whichever is the smaller.

2.5.Sample holderU.K.

The mechanism shall be capable of locating the test sample so that the axes of the source arm and receptor intersect at the reflecting surface. The reflecting surface may lie within or at either face of the mirror sample, depending on whether it is a first-surface, second-surface or prismatic ‘flip’-type mirror.

3.PROCEDUREU.K.

3.1.Direct calibration methodU.K.

In the direct calibration method, air is used as the reference standard. This method is applicable for those instruments, which are so constructed as to permit calibration at the 100 % point by swinging the receiver to a position directly on the axis of the light source (see Figure 4).

It may be desired in some cases (such as when measuring low-reflectivity surfaces) to use an intermediate calibration point (between 0 and 100 % on the scale) with this method. In these cases, a neutral density filter of known transmittance shall be inserted in the optical path, and the calibration control shall then be adjusted until the meter reads the percentage transmission of the neutral density filter. This filter shall be removed before reflectivity measurements are performed.

3.2.Indirect calibration methodU.K.

The indirect calibration method is applicable in the case of instruments with fixed source and receiver geometry. A properly calibrated and maintained reflectance standard is required. This reference standard should preferably be a flat mirror with a reflectance value as near as possible to that of the test samples.

3.3.Flat mirror measurementU.K.

The reflectance of flat mirror samples can be measured on instruments employing either the direct or the indirect calibration method. The reflectance value is read directly from the indicating meter.

3.4.Non-flat (convex) mirror measurementU.K.

Measurement of the reflectance of non-flat (convex) mirrors requires the use of instruments which incorporate an integrating sphere in the receiver unit (see Figure 5). If the instrument-indicating meter indicates ne divisions with a standard mirror of E % reflectance, then, with a mirror of unknown reflectance, nx divisions will correspond to a reflectance of X %, in accordance with the formula:

Spectral tristimulus values for the CIE 1931 standard colorimetric observer(2) U.K.

This table is taken from CIE publication 50 (45) (1970)

a

Changed in 1966 (from 3 to 2)

λnm (λ) (λ) (λ)
3800,00140,00,0065
3900,00420,00010,0201
4000,01430,00040,0679
4100,04350,00120,2074
4200,13440,0040,6456
4300,28390,01161,3856
4400,34830,0231,7471
4500,33620,0381,7721
4600,29080,061,6692
4700,19540,0911,2876
4800,09560,1390,813
4900,0320,2080,4652
5000,00490,3230,272
5100,00930,5030,1582
5200,06330,710,0782
5300,16550,8620,0422
5400,29040,9540,0203
5500,43340,9950,0087
5600,59450,9950,0039
5700,76210,9520,0021
5800,91630,870,0017
5901,02630,7570,0011
6001,06220,6310,0008
6101,00260,5030,0003
6200,85440,3810,0002
6300,64240,2650,0
6400,44790,1750,0
6500,28350,1070,0
6600,16490,0610,0
6700,08740,0320,0
6800,04680,0170,0
6900,02270,00820,0
7000,01140,00410,0
7100,00580,00210,0
7200,00290,0010,0
7300,00140,00050,0
7400,00070,0002a0,0
7500,00030,00010,0
7600,00020,00010,0
7700,00010,00,0
7800,00,00,0
(1)

Definitions taken from CIE publication 50 (45), International Electronical Vocabulary, Group 45: Lighting.

(2)

Abridged table. The values of (λ) = V(λ) are rounded off to four decimal places.

Back to top

Options/Help

Print Options

Close

Legislation is available in different versions:

Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.

Original (As adopted by EU): The original version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.

Point in Time: This becomes available after navigating to view revised legislation as it stood at a certain point in time via Advanced Features > Show Timeline of Changes or via a point in time advanced search.

Close

See additional information alongside the content

Geographical Extent: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.

Show Timeline of Changes: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.

Close

Opening Options

Different options to open legislation in order to view more content on screen at once

Close

More Resources

Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as adopted version that was used for the EU Official Journal
  • lists of changes made by and/or affecting this legislation item
  • all formats of all associated documents
  • correction slips
  • links to related legislation and further information resources
Close

Timeline of Changes

This timeline shows the different versions taken from EUR-Lex before exit day and during the implementation period as well as any subsequent versions created after the implementation period as a result of changes made by UK legislation.

The dates for the EU versions are taken from the document dates on EUR-Lex and may not always coincide with when the changes came into force for the document.

For any versions created after the implementation period as a result of changes made by UK legislation the date will coincide with the earliest date on which the change (e.g an insertion, a repeal or a substitution) that was applied came into force. For further information see our guide to revised legislation on Understanding Legislation.

Close

More Resources

Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as adopted version that was used for the print copy
  • correction slips

Click 'View More' or select 'More Resources' tab for additional information including:

  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • links to related legislation and further information resources