After exit day there will be three versions of this legislation to consult for different purposes. The legislation.gov.uk version is the version that applies in the UK. The EU Version currently on EUR-lex is the version that currently applies in the EU i.e you may need this if you operate a business in the EU.
The web archive version is the official version of this legislation item as it stood on exit day before being published to legislation.gov.uk and any subsequent UK changes and effects applied. The web archive also captured associated case law and other language formats from EUR-Lex.
EU Directives are being published on this site to aid cross referencing from UK legislation. After IP completion day (31 December 2020 11pm) no further amendments will be applied to this version.
Article 1.(1) Member States shall require that the analyses necessary for...
Article 2.Member States shall bring into force the laws, regulations or...
SCOPE OF TOE COMMUNITY METHODS OF ANALYSIS FOR CERTAIN SUGARS INTENDED FOR HUMAN CONSUMPTION
METHODS OF ANALYSIS TO VERIFY THE COMPOSITION OF CERTAIN SUGARS INTENDED FOR HUMAN CONSUMPTION
METHOD 1 DETERMINATION OF THE LOSS OF MASS ON DRYING
5.1. Vacuum drying oven, leak tight, thermostatically controlled and equipped with...
5.2. Air-drying train consisting of a glass tower filled with freshly...
5.3. Vaccum pump capable of maintaining the presure in the oven...
5.4. Metal weighing dish, flat-bottomed, resistant to attack by the samples...
5.5. Glass rod of a length such that it cannot completely...
5.6. Desiccator containing freshly activated dry silica gel, or an equivalent...
6.1. Pour approximately 30 g of kieselguhr (4.1) into the weighing...
6.2. Restore atmospheric pressure in the oven by cautiously increasing the...
63. Accurately weigh to the nearest 1 mg approximately 10 g...
6.5. Place the dish containing the test portion and the glass...
6.6. Restore atmospheric pressure in the oven by cautiously increasing the...
6.7. Continue operation (6.5) for a further four hours. Restore atmospheric...
6.8. For the determination of the dry matter in dextrose anhydrous...
4.1. Ethylene diamine tetra-acetic acid solution (disodium salt) (EDTA) 0·0025 mol/litre:...
4.2. Murexide indicator solution: add 0·25 g of murexide to 50...
4.3. Alkaline copper reagent: dissolve 25 g of anhydrous sodium carbonate...
4.4. Standard invert sugar solution: dissolve 23·750 g of pure sucrose...
4.5. Pure sucrose: sample of pure sucrose with an invert sugar...
6.1. Standardization of the Fehling's solution
6.1.1. Pipette 25 ml of Fehling's solution (4.1.3) into a clean,...
6.1.2. Fill the burette (5.2) with standard dextrose solution (4.3) and...
6.1.3. Run into the boiling flask (5.1) from the burette 18...
6.1.4. Place the boiling flask on the heating device (5.5), previously...
6.1.5. When boiling commences, start the stop-watch from zero.
6.1.6. Boil the contents of the flask for 120 seconds, as...
6.1.7. After boiling has continued for 120 seconds (by the stop-watch)...
6.1.9. Run into the boiling flask (5.1) from the burette a...
6.1.11. After boiling has continued for 120 seconds (by the stop-watch),...
6.1.12. Note the volume (Vo ml) of standard dextrose solution used...
6.1.13. Vo shall be between 19·0 and 21·0 ml standard dextrose...
6.1.14. For the day-to-day standardization of the mixed Fehling's solution, as...
6.2. Preliminary examination of the prepared sample
6.2.1. Unless the reducing power (2.1) of the prepared sample is...
6.2.2. Prepare a 2% m/v solution of the sample ‘Z’, having...
6.2.3. As 6.1.2, using the sample solution (6.2.2) in place of...
6.2.5. As 6.1.3, using 10·0 ml sample solution instead of 18·0...
6.2.8. Immediately boiling has started, start the stop-watch (5.6) from zero...
6.2.10. The approximate reducing power of the prepared sample in percent...
6.5.2. Fill the burette (5.2) with test solution (6.4) and adjust...
6.5.3. Run into the boiling flask from the burette 18·5 ml...
6.5.7. As 6.1.7, using test solution in place of standard dextrose...
6.5.9. As 6.1.9, using test solution in place of standard dextrose...
6.5.11. As 6.1.11, using test solution in place of standard dextrose...
6.5.13. V1 shall be between 19·0 and 21·0 ml test solution....
6.5.14. Carry out two determinations on the same test solution.
METHOD 9 DETERMINATION OF SULPHATED ASH
METHOD 10 DETERMINATION OF POLARIZATION
The Whole Directive you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.
Would you like to continue?
The Schedules you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.
Would you like to continue?
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As adopted by EU): The original version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
This timeline shows the different versions taken from EUR-Lex before exit day and during the implementation period as well as any subsequent versions created after the implementation period as a result of changes made by UK legislation.
The dates for the EU versions are taken from the document dates on EUR-Lex and may not always coincide with when the changes came into force for the document.
For any versions created after the implementation period as a result of changes made by UK legislation the date will coincide with the earliest date on which the change (e.g an insertion, a repeal or a substitution) that was applied came into force. For further information see our guide to revised legislation on Understanding Legislation.
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: