Search Legislation

The Energy Information (Household Refrigerators and Freezers) Regulations 2004

Status:

This is the original version (as it was originally made).

Regulations 7(2), 8(2)(d) and 12(b)

SCHEDULE 5ENERGY EFFICIENCY CLASS

This schedule has no associated Explanatory Memorandum

PART 1Definitions of Classes A+ and A++

1.—(1) An appliance shall be classified as A+ or A++ where the energy efficiency index alpha (I) is within the ranges specified in Table 1.

Table 1

Energy efficiency index α(Iα)“Energy efficiency class”
30 > IαA++
42 > Iα ≥ 30A+
Iα ≥ 42A to G (see below)

(2) The energy efficiency index alpha shall be calculated using the formula:

where—

“AC” means the annual energy consumption of the appliance (in accordance with the harmonised standards); and

“SCα” means the standard annual energy consumption α of the appliance.

“SCα” is calculated as:

where—

“Vc” means the net volume (in litres) of the compartment (in accordance with the harmonised standards);

“Tc” is the design temperature (in °C) of the compartment;

the values of M and N are given in Table 2; and

the values of FF, CC, BI and CH are given in Table 3.

Table 2

Type of applianceTemperature of coldest compartmentMαNα
(1)

For these appliances, the temperature and star rating of the compartment with the lowest temperature will determine the values of M and N. Appliances with –18°C *(***) compartments shall be considered as fridge-freezers *(***).

1. Larder Fridge>-6°C0.233245
2. Refrigerator/chillers>-6°C0.233245
3. Refrigerator no star>-6°C0.233245
4. Refrigerator*≤-6°C *0.643191
5. Refrigerator**≤-12°C **0.450245
6. Refrigerator***/≤-18°C ***/*(***)0.777303
7. Fridge/freezer *(***)≤-18°C ***/*(***)0.777303
8. Upright freezer≤-18°C *(***)0.539315
9. Chest freezer≤-18°C *(***)0.472286
10. Multi-door or other appliance(1)(1)

Table 3

Correction factorValueConditions
(1)

An appliance is “built-in” only if it is designed exclusively for installation within a kitchen cavity with a need of furniture finishings, and tested as such.

FF (frost free)

1.2

1

For “frost free” (ventilated) frozen food compartments;

Otherwise

CC (climate class)

1.2

1.1

1

For “tropical” appliances;

For “subtropical” appliances;

Otherwise

BI (built-in)

1.2

1

For built-in appliances (1) of under 58cm in width;

Otherwise

CH (chill compartment)

50 Kwh/y

0

For appliances with a chill compartment of at least 15 litres;

Otherwise

(3) If an appliance is not A+ or A++, it shall be classified in accordance with Part 2.

PART 2Definition of Classes A to G

2.  The energy efficiency class of an appliance shall be determined in accordance with Table 4.

Table 4

Energy efficiency index: IEnergy efficiency class
I < 55A
55 ≤ I < 75B
75 ≤ I < 90C
90 ≤ I < 100D
100 ≤ I < 110E
110 ≤ I < 125F
125 ≤ IG

where—

  • “energy efficiency index” (expressed as a percentage) = annual energy consumption of appliance in accordance with the harmonised standards / standard annual energy consumption of appliance;

  • “standard annual energy consumption of appliance” (expressed in kWh/year) = M × adjusted net volume + N;

  • “adjusted net volume” (expressed in litres) = net volume of fresh food compartment + Ω × net volume of frozen food compartment; andthe values of M, N and Ω are taken from Table 5.

    Table 5

    Category of ApplianceΩMN
    (1)

    For refrigerator/chiller the adjusted volume = net volume of fresh food compartment + Ω × net volume of chiller (10°C) compartment (expressed in litres).

    (2)

    For ‘no frost’ appliances as defined in the harmonised standards, this index is increased by a provisional factor of 1.2 giving a value of 2.58 (this allows for the possible bias of the measurement method, which does not allow for the lack of ice build-up on “no frost” appliances. In practice, ice build-up will somewhat increase the consumption of “conventional” appliances).

    (3)

    Adjusted net volume (AV) shall be calculated by the formula:

    where—

    • “Tc” is design temperature (in °C) of each compartment;

    • “Vc” is the net volume (in litres) of each compartment; and

    • “Fc” is a factor which equals 1.2 for “no frost” compartments and 1 for other compartments.

    (4)

    For these appliances, the values of M and N shall be determined by the temperature and star rating of the compartment with the lowest temperature, in accordance with Table 6.

    1. Larder fridge0.233245
    2. Refrigerator/chiller0.75(1)0.233245
    3. Refrigerator no star1.250.233245
    4. Refrigerator*1.550.643191
    5. Refrigerator**1.850.450245
    6. Refrigerator***2.150.657235
    7. Fridge/freezer*(***)0.777303
    8. Upright freezer2.15(2)0.472286
    9. Chest freezer2.15(2)0.446181
    10. Multi-door or other appliances

    Table 6

    Temperature of coldest compartmentEquivalent categoryMN
    >-6c
    1

    Larder fridge

    2

    Refrigerator/chiller

    3

    No-star refrigerator

    0.233245
    ≤ -6°C *4 Refrigerator (*)0.643191
    ≤ -12°C **5 Refrigerator (**)0.450245
    ≤-18°C ***6 Refrigerator (***)0.657235

    ≤-18°C *(***)with freezing capacity

    7 Fridge/freezer *(***)0.777303

Back to top

Options/Help

Print Options

Close

Legislation is available in different versions:

Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.

Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.

Close

Opening Options

Different options to open legislation in order to view more content on screen at once

Close

Explanatory Memorandum

Explanatory Memorandum sets out a brief statement of the purpose of a Statutory Instrument and provides information about its policy objective and policy implications. They aim to make the Statutory Instrument accessible to readers who are not legally qualified and accompany any Statutory Instrument or Draft Statutory Instrument laid before Parliament from June 2004 onwards.

Close

More Resources

Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as enacted version that was used for the print copy
  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • correction slips
  • links to related legislation and further information resources
Close

More Resources

Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as made version that was used for the print copy
  • correction slips

Click 'View More' or select 'More Resources' tab for additional information including:

  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • links to related legislation and further information resources