- Latest available (Revised)
- Original (As made)
This is the original version (as it was originally made). This item of legislation is currently only available in its original format.
2. Accuracy classes
2.1. The following accuracy class have been defined:
I | special |
II | high |
III | medium |
IIII | ordinary |
The Specifications of these classes are given in Table 1.
The minimum capacity is reduced to 5e for instruments in classes II and III for determining a conveying tariff.
2.2. Scale intervals
2.2.1.The actual scale interval (d) and the verification scale interval (e) shall be in the form:1 × 10k, 2 × 10k, or 5 × 10k mass units,
k being any integer or zero.
2.2.2.For all instruments other than those with auxiliary indicating devices: d = e
2.2.3.For instruments with auxiliary indicating devices the following conditions apply:
e = 1 × 10kg
d < e ≤ 10d
except for instruments of class I with d < 10−4g, for which e = 10−3g.
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include: