Commission Regulation (EU) 2015/1188 of 28 April 2015 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for local space heaters (Text with EEA relevance)
When the UK left the EU, legislation.gov.uk published EU legislation that had been published by the EU up to IP completion day (31 December 2020 11.00 p.m.). On legislation.gov.uk, these items of legislation are kept up-to-date with any amendments made by the UK since then.
Legislation.gov.uk publishes the UK version. EUR-Lex publishes the EU version. The EU Exit Web Archive holds a snapshot of EUR-Lex’s version from IP completion day (31 December 2020 11.00 p.m.).
There are currently no known outstanding effects by UK legislation for Commission Regulation (EU) 2015/1188.
Revised legislation carried on this site may not be fully up to date. At the current time any known changes or effects made by subsequent legislation have been applied to the text of the legislation you are viewing by the editorial team. Please see ‘Frequently Asked Questions’ for details regarding the timescales for which new effects are identified and recorded on this site.
This Regulation establishes ecodesign requirements for the placing on the market and putting into service of domestic local space heaters with a nominal heat output of 50 kW or less and commercial local space heaters with a nominal heat output of the product or of a single segment of 120 kW or less.
This Regulation shall not apply to:
local space heaters using a vapour compression cycle or sorption cycle for the generation of heat driven by electric compressors or fuel;
local space heaters specified for purposes other than indoor space heating to reach and maintain a certain thermal comfort of human beings by means of heat convection or heat radiation;
local space heaters that are specified for outdoor use only;
local space heaters of which the direct heat output is less than 6 % of the combined direct and indirect heat output at nominal heat output;
air heating products;
sauna stoves;
slave heaters.
[F1The definitions set out in the Ecodesign for Energy-Related Products Regulations 2010 apply; and for any term that is not defined in those Regulations, the definitions set out in Directive 2009/125/EC of the European Parliament and of the Council of 21 October 2009 establishing a framework for the setting of ecodesign requirements for energy-related products, as it had effect immediately before IP completion day, apply. The following definitions also apply—]
‘local space heater’ means a space heating device that emits heat by direct heat transfer or by direct heat transfer in combination with heat transfer to a fluid, in order to reach and maintain a certain level of human thermal comfort within an enclosed space in which the product is situated, possibly combined with a heat output to other spaces and is equipped with one or more heat generators that convert electricity or gaseous or liquid fuels directly into heat, through use of the Joule effect or combustion of fuels respectively;
‘domestic local space heater’ means a local space heater other than a commercial one;
‘gaseous fuel local space heater’ means an open fronted local space heater or a closed fronted local space heater using gaseous fuel;
‘liquid fuel local space heater’ means an open fronted local space heater or a closed fronted local space heater using liquid fuel;
‘electric local space heater’ means a local space heater using the electric Joule effect to generate heat;
‘commercial local space heater’ means either a luminous local space heater or tube local space heater;
‘open fronted local space heater’ means a local space heater, using gaseous or liquid fuels, of which the fire bed and combustion gases are not sealed from the space in which the product is fitted and which is sealed to a chimney or fireplace opening or requires a flue duct for the evacuation of products of combustion;
‘closed fronted local space heater’ means a local space heater, using gaseous or liquid fuels, of which the fire bed and combustion gases are sealed from the space in which the product is fitted and which is sealed to a chimney or fireplace opening or requires a flue duct for the evacuation of products of combustion;
‘electric portable local space heater’ means an electric local space heater which is not an electric fixed local space heater, electric storage local space heater, electric underfloor local space heater, electric radiant local space heater, electric visibly glowing local space heater or slave heater;
‘electric fixed local space heater’ means an electric local space heater not intended to accumulate thermal energy and designed to be used while fastened or secured in a specific location or wall mounted and not incorporated in the building structure or building finishing;
‘electric storage local space heater’ means an electric local space heater designed to store heat in an accumulating isolated core and to discharge it for several hours after the accumulation phase;
‘electric underfloor local space heater’ means an electric local space heater designed to be used while incorporated in the building structure or building finishing;
‘electric radiant local space heater’ means an electric local space heater in which the heat emitting element is to be directed towards the place of use so that its thermal radiation directly warms the subjects to be heated and which has a temperature rise of the grill covering the heat emitting element of at least 130 °C in normal use and/or a temperature rise of 100 °C for other surfaces;
‘electric visibly glowing radiant local space heater’ means an electric local space heater in which the heating element is visible from outside the heater and has a temperature of at least 650 °C in normal use;
‘sauna stove’ means a space heating product, incorporated in, or declared to be used in, dry or wet sauna's or similar environments;
‘slave heater’ means an electric local space heater which is not capable of autonomous operation and needs to receive signals sent from an external master controller, not being part of the product but connected to it by pilot wire, wireless, power line communication or an equivalent technique, in order to regulate the emission of heat into the room in which the product is installed;
‘luminous local space heater’ means a local space heater, using gaseous or liquid fuel which is equipped with a burner; which is to be installed above head level, directed towards the place of use so that the heat emission of the burner, being predominantly infrared radiation, directly warms the subjects to be heated and which emits the products of combustion in the space where it is situated;
‘tube local space heater’ means a local space heater, using gaseous or liquid fuel, which is equipped with a burner; which is to be installed above head level, near the subjects to be heated, which heats the space primarily by infrared radiation from the tube or tubes heated by the internal passage of products of combustion and of which the products of combustion are to be evacuated through a flue duct;
‘tube heater system’ means a tube local space heater comprising more than one single burner, of which the products of combustion of one burner may feed into a next burner, and of which the products of combustion of multiple burners are to be evacuated by a single exhaust fan;
‘tube heater segment’ means a part of a tube heater system that comprises all the elements needed for standalone operation and as such can be tested independently of the other tube heating system parts;
‘flueless heater’ means a local space heater using gaseous or liquid fuel emitting the products of combustion into the space where the product is situated, other than a luminous local space heater;
‘open to chimney heater’ means a local space heater using gaseous or liquid fuels intended to sit under a chimney or in a fireplace without sealing between the product and the chimney or fireplace opening, and allowing the products of combustion pass unrestricted from the fire bed to the chimney or flue;
‘air heating product’ means a product providing heat to an air-based heating system only that can be ducted and is designed to be used while fastened or secured in a specific location or wall mounted which distributes the air by means of an air moving device in order to reach and maintain a certain level of human thermal comfort within an enclosed space in which the product is situated;
‘direct heat output’ means the heat output of the product by radiation and convection of heat, as emitted by or from the product itself to air, excluding the heat output of the product to a heat transfer fluid, expressed in kW;
‘indirect heat output’ means the heat output of the product to a heat transfer fluid by the same heat generation process that provides the direct heat output of the product, expressed in kW;
‘indirect heating functionality’ means the product is capable of transferring part of the total heat output to a heat transfer fluid, for use as space heating or domestic hot water generation;
‘nominal heat output’ (Pnom ) means the heat output of a local space heater comprising both direct heat output and indirect heat output (where applicable), when operating at the setting for the maximum heat output that can be maintained over an extended period, as declared by the manufacturer, expressed in kW;
‘minimum heat output’ (Pmin ) means the heat output of a local space heater comprising both direct heat output and indirect heat output (where applicable), when operating at the setting for the lowest heat output, as declared by the manufacturer, expressed in kW;
‘maximum continuous heat output’ (Pmax,c ) means the declared heat output of an electric local space heater when operating at the setting for the maximum heat output that can be maintained continuously over an extended period, as declared by the manufacturer, expressed in kW;
‘intended for outdoor use’ means the product is suitable for safe operation outside enclosed spaces, including possible use in outdoor conditions;
‘equivalent model’ means a model placed on the market with the same technical parameters set out in Table 1, Table 2 or Table 3 of point 3 of Annex II as another model placed on the market by the same manufacturer.
For Annexes II to V, additional definitions are set out in Annex I.
Textual Amendments
F1Words in Art. 2 substituted (31.12.2020) by The Ecodesign for Energy-Related Products and Energy Information (Amendment) (EU Exit) Regulations 2019 (S.I. 2019/539), reg. 1(3), Sch. 2 para. 26(2) (as amended by S.I. 2020/1528, regs. 1(2), 4); 2020 c. 1, Sch. 5 para. 1(1)
1.The ecodesign requirements for local space heaters are set out in Annex II.
2.Local space heaters shall meet the requirements set out in Annex II from 1 January 2018.
3.Compliance with ecodesign requirements shall be measured and calculated in accordance with the methods set out in Annex III.
[F21. For the purposes of regulation 4(2)(a) of the Ecodesign for Energy-Related Products Regulations 2010, the procedure for assessing whether an energy-related product complies with this implementing measure is the internal design control system set out in Part 1 of Schedule 1A to the Ecodesign for Energy-Related Products Regulations 2010 or the management system for assessing conformity set out in Part 2 of Schedule 1A to those Regulations.]
2.For the purposes of the conformity assessment pursuant to [F3regulation 4(2)(a) of the Ecodesign for Energy-Related Products Regulations 2010], the technical documentation shall contain the information set out in point 3(b) of Annex II to this Regulation.
3.Where the information included in the technical documentation for a model has been obtained by calculation on the basis of design, or extrapolation from other equivalent appliances, or both, the technical documentation shall include details of such calculations or extrapolations, or both, and of tests undertaken by manufacturers to verify the accuracy of the calculations undertaken. In such cases, the technical documentation shall also include a list of all other equivalent models where the information contained in the technical documentation was obtained on the same basis.
Textual Amendments
When performing market surveillance checks to assess compliance with the requirements set out in Annex 2, the authorities of Great Britain must apply the verification procedure described in Annex 4.]
Textual Amendments
F4Art. 5 substituted (31.12.2020) by The Ecodesign for Energy-Related Products and Energy Information (Amendment) (EU Exit) Regulations 2019 (S.I. 2019/539), reg. 1(3), Sch. 2 para. 26(4) (as amended by S.I. 2020/1528, regs. 1(2), 6(3)(4)(b)(xxiv)); 2020 c. 1, Sch. 5 para. 1(1)
The indicative benchmarks for best-performing local space heaters available on the market at the time of entry into force of this Regulation are set out in Annex V.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Textual Amendments
Until 1 January 2018 Member States may allow the placing on the market and putting into service of local space heaters which are in conformity with the national provisions in force regarding seasonal space heating energy efficiency and nitrogen oxides.
This Regulation shall enter into force on the twentieth day following that of its publication in the Official Journal of the European Union.
F6...
Textual Amendments
F6Words in Signature omitted (31.12.2020) by virtue of The Ecodesign for Energy-Related Products and Energy Information (Amendment) (EU Exit) Regulations 2019 (S.I. 2019/539), reg. 1(3), Sch. 2 para. 26(6); 2020 c. 1, Sch. 5 para. 1(1)
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As adopted by EU): The original version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.
Geographical Extent: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.
Show Timeline of Changes: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
This timeline shows the different versions taken from EUR-Lex before exit day and during the implementation period as well as any subsequent versions created after the implementation period as a result of changes made by UK legislation.
The dates for the EU versions are taken from the document dates on EUR-Lex and may not always coincide with when the changes came into force for the document.
For any versions created after the implementation period as a result of changes made by UK legislation the date will coincide with the earliest date on which the change (e.g an insertion, a repeal or a substitution) that was applied came into force. For further information see our guide to revised legislation on Understanding Legislation.
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: