the fuel consumption in litres per 100 km in the case of petrol, ethanol, LPG, diesel or biodiesel, in m3 per 100 km in the case of natural gas and H2NG or in kg per 100 km in the case of hydrogen.
=
the measured emission of hydrocarbons in mg/km
=
the measured emission of carbon monoxide in mg/km
=
the measured emission of carbon dioxide in g/km
=
the measured emission of water (H2O) in g/km
=
the measured emission of hydrogen (H2) in g/km
=
the quantity of NG/biomethane in the H2NG mixture, expressed in percent by volume
=
the density of the test fuel.
In the case of gaseous fuels, D is the density at 15 °C and at 101,3 kPa ambient pressure:
=
theoretical distance covered by a vehicle tested under the type I test in km
=
pressure in gaseous fuel tank before the operating cycle in Pa
=
pressure in gaseous fuel tank after the operating cycle in Pa
=
temperature in gaseous fuel tank before the operating cycle in K
=
temperature in gaseous fuel tank after the operating cycle in K
=
compressibility factor of the gaseous fuel at p1 and T1
=
compressibility factor of the gaseous fuel at p2 and T2
=
inner volume of the gaseous fuel tank in m3
The compressibility factor shall be obtained from the following table:
| Table Ap1-1 | ||||||||||
| Compressibility factor Zx of the gaseous fuel | ||||||||||
| T(k) \ p(bar) | 5 | 100 | 200 | 300 | 400 | 500 | 600 | 700 | 800 | 900 |
|---|---|---|---|---|---|---|---|---|---|---|
| 33 | 0,8589 | 10,508 | 18,854 | 26,477 | 33,652 | 40,509 | 47,119 | 53,519 | 59,73 | 65,759 |
| 53 | 0,9651 | 0,9221 | 14,158 | 18,906 | 23,384 | 27,646 | 31,739 | 35,697 | 39,541 | 43,287 |
| 73 | 0,9888 | 0,9911 | 12,779 | 16,038 | 19,225 | 22,292 | 25,247 | 28,104 | 30,877 | 33,577 |
| 93 | 0,997 | 10,422 | 12,334 | 14,696 | 17,107 | 19,472 | 21,771 | 24,003 | 26,172 | 28,286 |
| 113 | 10,004 | 10,659 | 12,131 | 13,951 | 15,86 | 17,764 | 19,633 | 21,458 | 23,239 | 24,978 |
| 133 | 10,019 | 10,757 | 11,99 | 13,471 | 15,039 | 16,623 | 18,19 | 19,73 | 21,238 | 22,714 |
| 153 | 10,026 | 10,788 | 11,868 | 13,123 | 14,453 | 15,804 | 17,15 | 18,479 | 19,785 | 21,067 |
| 173 | 10,029 | 10,785 | 11,757 | 12,851 | 14,006 | 15,183 | 16,361 | 17,528 | 18,679 | 19,811 |
| 193 | 10,03 | 10,765 | 11,653 | 12,628 | 13,651 | 14,693 | 15,739 | 16,779 | 17,807 | 18,82 |
| 213 | 10,028 | 10,705 | 11,468 | 12,276 | 13,111 | 13,962 | 14,817 | 15,669 | 16,515 | 17,352 |
| 233 | 10,035 | 10,712 | 11,475 | 12,282 | 13,118 | 13,968 | 14,823 | 15,675 | 16,521 | 17,358 |
| 248 | 10,034 | 10,687 | 11,413 | 12,173 | 12,956 | 13,752 | 14,552 | 15,35 | 16,143 | 16,929 |
| 263 | 10,033 | 10,663 | 11,355 | 12,073 | 12,811 | 13,559 | 14,311 | 15,062 | 15,808 | 16,548 |
| 278 | 10,032 | 10,64 | 11,3 | 11,982 | 12,679 | 13,385 | 14,094 | 14,803 | 15,508 | 16,207 |
| 293 | 10,031 | 10,617 | 11,249 | 11,897 | 12,558 | 13,227 | 13,899 | 14,57 | 15,237 | 15,9 |
| 308 | 10,03 | 10,595 | 11,201 | 11,819 | 12,448 | 13,083 | 13,721 | 14,358 | 14,992 | 15,623 |
| 323 | 10,029 | 10,574 | 11,156 | 11,747 | 12,347 | 12,952 | 13,559 | 14,165 | 14,769 | 15,37 |
| 338 | 10,028 | 10,554 | 11,113 | 11,68 | 12,253 | 12,83 | 13,41 | 13,988 | 14,565 | 15,138 |
| 353 | 10,027 | 10,535 | 11,073 | 11,617 | 12,166 | 12,718 | 13,272 | 13,826 | 14,377 | 14,926 |
The Whole Regulation you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.
Would you like to continue?
The Schedules you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.
Would you like to continue?
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As adopted by EU): The original version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: