Regulations 2, 4, 5, 6 and 11

SCHEDULE

PART 1Introduction to Parts 2 and 3

1.  In this Schedule—

“contact current (IC)” is the current created when a person comes into contact with an object in an electromagnetic field, expressed in ampères (A);

“external electric field strength (E)” is a vector quantity corresponding to the force exerted on a charged particle in the environment, irrespective of its motion in space, expressed in volts per metre (Vm-1);

“internal electric field strength (E)” is a vector quantity corresponding to the force exerted on a charged particle inside the human body, irrespective of its motion in space, expressed in volts per metre (Vm-1);

“limb current (IL)” is the current induced in the limbs of a person exposed to electromagnetic fields in the frequency range from 10 MHz to 110 MHz, expressed in ampères (A);

“magnetic flux density (B)” is a vector quantity resulting in a force that acts on moving charges, expressed in tesla (T);

“power density (S)” is the radiant power incident perpendicular to a surface, divided by the area of the surface, expressed in watts per square metre (Wm-2);

“specific energy absorption (SA)” is the energy absorbed per unit mass of biological tissue, expressed in joules per kilogram (Jkg-1);

“specific energy absorption rate (SAR)” is the rate at which energy is absorbed per unit mass of body tissue, expressed in watts per kilogram (Wkg-1).

2.  The ALs and ELVs are set out in tables and grouped according to their potential effects, being—

(a)thermal effects, related to the heating of tissue due to its absorption of electromagnetic fields; and

(b)non-thermal effects, related to the stimulation of nerves or sensory organs due to the presence of electromagnetic fields.

3.  The Low ALs in Table AL1 in Part 2, and the ALs in Part 3, specify the electromagnetic field levels above which specific indirect effects may occur.

4.  The remaining ALs in Part 2 are defined physical quantities related to the direct biophysical effects of exposure to electromagnetic fields. Employers may, as part of their exposure assessment, assess electromagnetic field levels against these ALs. Each AL table states which ELV or ELVs will be complied with if electromagnetic field levels at a particular frequency do not exceed that AL. Exposure to electromagnetic field levels in excess of the AL may still be below the relevant ELV but the employer will have to undertake further assessment to determine this under regulation 5.

5.  Except where otherwise indicated—

(a)“f” is the frequency expressed in hertz;

(b)the ALs and ELVs relate to exposure in any part of the body; and

(c)notes to the tables apply only to the table under which they appear.

6.  The applicable safety measures referred to in regulation 4(2) are those required by the notes to the table or tables containing the sensory effect ELV which is to be exceeded, being—

(a)the note to Table ELV1; and

(b)note 2 to Tables ELV3 and ELV5.

PART 2Direct biophysical effects of exposure

Action levels – non-thermal effects

Table AL1 – ALs for exposure to electromagnetic fields from 1 Hz to 10 MHz
Frequency rangeExternal electric field strength Low ALs (E) [Vm-1]External electric field strength High ALs (E) [Vm-1]
1 ≤ f < 25 Hz2.0 × 1042.0 × 104
25 ≤ f < 50 Hz5.0 × 105/f2.0 × 104
50 Hz ≤ f < 1.64 kHz5.0 × 105/f1.0 × 106/f
1.64 ≤ f < 3 kHz5.0 × 105/f6.1 × 102
3 kHz ≤ f ≤ 10 MHz1.7 × 1026.1 × 102
Exposure levels not exceeding the ALs will be compliant with:

Tables ELV2 and ELV3

Notes

1.  Between the Low and High ALs, exposure will be below the ELVs but spark discharges may occur. These can be prevented through the provision of information and training under regulation 10 and the use of suitable technical and personal protection measures.

2.  The ALs in Tables AL1 and AL2 are root mean square (RMS) values of the field strength. These RMS values are equal to the peak values divided by √2 for sinusoidal fields. The corresponding ELVs in Tables ELV2 and ELV3 are peak values in time, which are equal to the RMS values multiplied by √2 for sinusoidal fields. In the case of non-sinusoidal fields the exposure assessment under regulation 5 must be based on the weighted peak method (filtering in time domain) or on a scientifically proven and validated exposure evaluation procedure which produces comparable results to the weighted peak method.

3.  The ALs represent the maximum field values at any place where an employee may be working, before the entry of any person into the field. In the case of an electromagnetic field source in the immediate vicinity of the body, compliance with the ELVs must be determined dosimetrically, case by case.

Table AL2 – ALs for exposure to electromagnetic fields from 1 Hz to 10 MHz
Frequency rangeMagnetic flux density Low ALs (B)[µT]Magnetic flux density High ALs (B)[µT]Magnetic flux density ALs for exposure of limbs to a localised magnetic field (B) [µT]
1 ≤ f < 8 Hz2.0 × 105/f23.0 × 105/f9.0 × 105/f
8 ≤ f < 25 Hz2.5 × 104/f3.0 × 105/f9.0 × 105/f
25 ≤ f < 300 Hz1.0 × 1033.0 × 105/f9.0 × 105/f
300 Hz ≤ f < 3 kHz3.0 × 105/f3.0 × 105/f9.0 × 105/f
3 kHz ≤ f ≤ 10 MHz1.0 × 1021.0 × 1023.0 × 102
Exposure levels not exceeding the ALs will be compliant with:At and below 400 Hz: the sensory effect ELVs in Table ELV3The health effect ELVs in Table ELV2
Above 400 Hz: the health effect ELVs in Table ELV2
Notes

1.  Between the Low and High ALs for exposure up to 400 Hz, exposure in the head of the employee will be below the health effect ELVs but may exceed the sensory effect ELVs in Table ELV3.

2.  Notes 2 and 3 to Table AL1 apply.

Action levels – thermal effects

Table AL3 – ALs for exposure to electromagnetic fields from 100 kHz to 300 GHz
Frequency rangeExternal electric field strength ALs (E) [Vm-1]Magnetic flux density ALs (B)[µT]Power density AL (S)[Wm-2]
100 kHz ≤ f < 1 MHz6.1 × 1022.0 × 106/f-
1 ≤ f < 10 MHz6.1 × 108/f2.0 × 106/f-
10 ≤ f < 400 MHz610.2-
400 MHz ≤ f < 2 GHz3 × 10-3 f1/21.0 × 10-5 f1/2-
2 ≤ f < 6 GHz1.4 × 1024.5 × 10-1-
6 ≤ f ≤ 300 GHz1.4 × 1024.5 × 10-150
Exposure levels not exceeding the ALs will be compliant with:

Up to 6 GHz: the health effect ELVs in Table ELV4

6 - 300 GHz: the health effect ELV in Table ELV6

The health effect ELV in Table ELV6
Notes

1.  The electric field strength and magnetic flux density ALs are root mean square values.

2.  For radiofrequency pulses, the peak power density averaged over the pulse width must not exceed 1000 times the respective AL (S) value. For multi-frequency fields, the analysis must be based on summation.

3.  Note 3 to Table AL1 applies in relation to the ALs for external electric field strength and magnetic flux density.

4.  The power density is the maximum level averaged over any 20cm2 of exposed area. Spatial maximum power densities averaged over 1cm2 must not exceed 20 times the value of 50 Wm-2.

5.  From 6 to 10 GHz, power density must be averaged over a six minute period. Above 10 GHz, it must be averaged over a 68/f1.05-minute period (where “f” is the frequency in GHz).

Table AL4 – AL for exposure to electromagnetic fields from 10 to 110MHz
Frequency rangeLimb current AL (IL) [mA]
10 ≤ f ≤ 110 MHz100
Exposure levels not exceeding the ALs will be compliant with:The health effect ELV in Table ELV4 - localised SAR in the limbs
Note

The AL is a root mean square value.

Exposure limit values – non-thermal effects

Table ELV1 – ELVs for exposure to electromagnetic fields from 0 to 1 Hz
Sensory effect ELVs – magnetic flux density (B0) [T]
Head and trunk2
Limbs8
Health effect ELV – magnetic flux density (B0) [T]
Any part of the body8
Note

The sensory effect ELVs may be exceeded during an employee’s shift where the employer ensures that—

(a)they are only exceeded temporarily;

(b)protection measures have been adopted which minimise, so far as is reasonably practicable, the sensory effects related to movement in static magnetic fields, including nausea and vertigo;

(c)adequate information is provided to the employee on the possibility of those sensory effects; and

(d)where any of those sensory effects are reported to the employer, the exposure assessment under regulation 5, and the protection measures, are updated where necessary.

Table ELV2 – Health effect ELVs for exposure to electromagnetic fields from 1 Hz to 10 MHz
Frequency rangeHealth effect ELVs – internal electric field strength (E) [Vm-1]
1 Hz ≤ f < 3 kHz1.1
3 kHz ≤ f ≤ 10 MHz3.8 × 10-4 f
Notes

1.  The ELVs are limits for electric fields induced in the body from exposure to time-varying electric and magnetic fields.

2.  The ELVs are spatial peak values in the entire body of the employee.

3.  Note 2 to Table AL1 applies in relation to methods of determining exposure.

Table ELV3 – Sensory effect ELVs for exposure to electromagnetic fields from 1 to 400 Hz
Frequency rangeSensory effect ELVs – internal electric field strength in the head (E) [Vm-1]
1 ≤ f < 10 Hz0.7/f
10 ≤ f < 25 Hz0.07
25 ≤ f ≤ 400 Hz0.0028 f
Notes

1.  The ELVs are spatial peak values induced in the head of the exposed employee, and can arise from exposure to either external electric or external magnetic fields.

2.  The ELVs may be exceeded during an employee’s shift where the employer ensures that—

(a)they are only exceeded temporarily;

(b)hazardous spark discharges, and contact currents in excess of those in Table AL5, are prevented through the provision of information and training under regulation 10 and the use of suitable technical and personal protection measures;

(c)adequate information is provided to the employee on the possibility of sensory effects related to time-varying magnetic fields, including retinal phosphenes; and

(d)where any of those sensory effects are reported to the employer, the risk assessment is updated where necessary.

3.  Note 2 to Table AL1 applies in relation to methods of determining exposure.

Exposure limit values – thermal effects

Table ELV4 – Health effect ELVs for exposure to electromagnetic fields from 100 kHz to 6 GHz
Area of exposureHealth effect ELVs – specific energy absorption rate (SAR) [Wkg-1]
Whole body0.4 (averaged SAR in the body)
Head and trunk10 (localised SAR in the head and trunk)
Limbs20 (localised SAR in the limbs)
Notes

1.  The ELVs correspond to the SAR values averaged over a six minute period.

2.  Localised SAR in the body and limbs can be assessed by either computational dosimetry or physical measurement of 10 grams of tissue. For computational dosimetry, 10 grams of contiguous tissue with approximately homogeneous electrical properties must be used for the SAR average. For direct physical measurements a simple geometry, such as cubic or spherical tissue mass, may be used. The maximum value obtained must be assessed against the ELVs.

Table ELV5 – Sensory effect ELV for exposure to electromagnetic fields from 300 MHz to 6 GHz
Frequency rangeSensory effect ELV – specific energy absorption in the head (SA) [mJkg-1]
300 MHz ≤ f ≤ 6GHz10
Notes

1.  When determining SA, energy absorption must be averaged over 10 grams of tissue.

2.  The ELV may be exceeded during an employee’s shift where the employer ensures that—

(a)it is only exceeded temporarily;

(b)adequate information is provided to the employee on the possibility of sensory effects related to pulsed microwave radiation, including auditory sensations; and

(c)where any of those sensory effects are reported to the employer, the risk assessment is updated where necessary.

Table ELV6 – Health effect ELV for exposure to electromagnetic fields from 6 to 300 GHz
Frequency rangeHealth effect ELV – power density (S) [Wm-2]
6 GHz ≤ f ≤ 300GHz50
Notes

1.  The power density is the maximum level averaged over any 20cm2 of exposed area. Spatial maximum power densities averaged over 1cm2 must not exceed 20 times the value of 50 Wm-2.

2.  From 6 to 10 GHz, power density must be averaged over a six minute period. Above 10 GHz, it must be averaged over a 68/f1.05-minute period (where “f” is the frequency in GHz).

PART 3Indirect effects of exposure

Action levels – non-thermal effects

Table AL5 – ALs for contact currents
Frequency of electromagnetic field in which an object is presentContact current ALs (IC) [mA]
up to 2.5 kHz1.0
2.5 ≤ f < 100 kHz0.4 f
100 ≤ f ≤10,000 kHz40
Notes

1.  “f” is the frequency expressed in kHz.

2.  The ALs are root mean square values.

3.  The ALs represent the maximum steady state current created during a continuous contact with an object in an electromagnetic field.

Table AL6 – ALs for static magnetic fields
Potential indirect effectMagnetic flux density ALs (B0) [mT]
Interference with active implanted medical devices0.5
Attraction and projectile risk in the fringe field of high field strength sources (> 100 mT)3
Note

The AL for interference with active implanted medical devices represents the maximum field value at any place where an employee may be working.

Action levels – thermal effects

Table AL7 – AL for contact currents
Frequency of electromagnetic field in which an object is presentContact current AL (IC) [mA]
100 kHz ≤ f < 110 MHz40
Notes

1.  The AL is a root mean square value.

2.  The AL represents the maximum steady state current created during a continuous contact with an object in an electromagnetic field.

Back to top

Options/Help

Print Options

Close

Legislation is available in different versions:

Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.

Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.

Close

Opening Options

Different options to open legislation in order to view more content on screen at once

Close

Explanatory Memorandum

Explanatory Memorandum sets out a brief statement of the purpose of a Statutory Instrument and provides information about its policy objective and policy implications. They aim to make the Statutory Instrument accessible to readers who are not legally qualified and accompany any Statutory Instrument or Draft Statutory Instrument laid before Parliament from June 2004 onwards.

Close

More Resources

Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as enacted version that was used for the print copy
  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • correction slips
  • links to related legislation and further information resources
Close

Impact Assessments

Impact Assessments generally accompany all UK Government interventions of a regulatory nature that affect the private sector, civil society organisations and public services. They apply regardless of whether the regulation originates from a domestic or international source and can accompany primary (Acts etc) and secondary legislation (SIs). An Impact Assessment allows those with an interest in the policy area to understand:

  • Why the government is proposing to intervene;
  • The main options the government is considering, and which one is preferred;
  • How and to what extent new policies may impact on them; and,
  • The estimated costs and benefits of proposed measures.
Close

More Resources

Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as made version that was used for the print copy
  • correction slips

Click 'View More' or select 'More Resources' tab for additional information including:

  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • links to related legislation and further information resources