xmlns:atom="http://www.w3.org/2005/Atom" xmlns:atom="http://www.w3.org/2005/Atom"

[F1SCHEDULE 1AE+W+S(Annex to the Directive)

6.3.1.3.1.4.  Each aerosol dispenser is to be tested:E+W+S

(a)when full according to the complete procedure, with the gas burner in the range of 15-90cm distance from the actuator of the aerosol can;

(b)when 10-12% full nominal (% by mass) only one test, either at 15cm distance from the actuator when the spray from a full can did not ignite at all, or at the flame ignition distance of the spray of a full can plus 15cm.]