Revised legislation carried on this site may not be fully up to date. At the current time any known changes or effects made by subsequent legislation have been applied to the text of the legislation you are viewing by the editorial team. Please see ‘Frequently Asked Questions’ for details regarding the timescales for which new effects are identified and recorded on this site.

PART IIIE+W+S CONTAINMENT MEASURES FOR INDUSTRIAL PROCESSES

Containment measuresContainment levels
234
1Viable micro-organisms should be contained in a system which physically separates the process from the environment (closed system).YesYesYes
2Exhaust gases from the closed system should be treated so as to—Minimise releasePrevent releasePrevent release
3Sample collection, addition of materials to a closed system and transfer of viable micro-organisms to another closed system, should be performed so as to—Minimise releasePrevent releasePrevent release
4Bulk culture fluids should not be removed from the closed system unless the viable micro-organisms have been—Inactivated by validated meansInactivated by validated chemical or physical meansInactivated by validated chemical or physical means
5Seals should be designed so as to—Minimise releasePrevent releasePrevent release
6Closed systems should be located within a controlled area—OptionalOptionalYes, and purpose-built

(a)biohazard signs should be posted;

OptionalYesYes

(b)access should be restricted to nominated personnel only;

OptionalYesYes, via air-lock

(c)personnel should wear protective clothing;

Yes, work clothingYesYes, a complete change

(d)decontamination and washing facilities should be provided for personnel;

YesYesYes

(e)personnel should shower before leaving the controlled area;

NoOptionalYes

(f)effluent from sinks and showers should be collected and inactivated before release;

NoOptionalYes

(g)the controlled area should be adequately ventilated to minimise air contamination;

OptionalOptionalYes

(h)the controlled area should be maintained at an air pressure negative to atmosphere;

NoOptionalYes

(i)input and extract air to the controlled area should be HEPA filtered;

NoOptionalYes

(j)the controlled area should be designed to contain spillage of the entire contents of closed system;

OptionalYesYes

(k)the controlled area should be sealable to permit fumigation.

NoOptionalYes
7Effluent treatment before final discharge.Inactivated by validated meansInactivated by validated chemical or physical meansInactivated by validated physical means

Back to top

Options/Help

Print Options

Close

Legislation is available in different versions:

Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.

Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.

Close

See additional information alongside the content

Geographical Extent: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.

Show Timeline of Changes: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.

Close

Opening Options

Different options to open legislation in order to view more content on screen at once

Close

More Resources

Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as enacted version that was used for the print copy
  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • correction slips
  • links to related legislation and further information resources
Close

Timeline of Changes

This timeline shows the different points in time where a change occurred. The dates will coincide with the earliest date on which the change (e.g an insertion, a repeal or a substitution) that was applied came into force. The first date in the timeline will usually be the earliest date when the provision came into force. In some cases the first date is 01/02/1991 (or for Northern Ireland legislation 01/01/2006). This date is our basedate. No versions before this date are available. For further information see the Editorial Practice Guide and Glossary under Help.

Close

More Resources

Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as made version that was used for the print copy
  • correction slips

Click 'View More' or select 'More Resources' tab for additional information including:

  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • links to related legislation and further information resources