a  P el for welding generators: conventional welding current multiplied by the conventional load voltage for the lowest value of the duty factor given by the manufacturer. P el for power generators: prime power according to ISO 8528-1:1993, clause 13.3.2.,
b For the following types of equipment the figures for Stage I shall continue to apply for Stage II — Walk-behind vibrating rollers; Vibratory plates (&gt;3 kW ); Vibratory rammers; Dozers (steel tracked); Loaders (steel tracked &gt;55 kW ); Combustion-engine driver counterbalanced lift trucks; Compacting screed paver-finishers; and Hand-held internal combustion-engine concrete-breakers and picks (15&lt; m&lt;30).,
c For single engine mobile cranes the figures for Stage I shall continue to apply until 3rd January 2008. After that date, Stage II figures shall apply.,
Compaction machines (vibrating rollers, vibratory plates, vibratory rammers), P ≤ £ 8,108,105,
8 &lt; P ≤ £70,109,106,
 P &gt; 70,89 + 11 1g P,86 + 11 1g P,
Tracked dozers, tracked loaders, tracked excavator-loaders, P ≤ 55,106,103,
 P &gt; 55,87 + 11 1g P,84 + 11 1g P,
Wheeled dozers,wheeled loaders, wheeled excavator-loaders, dumpers, graders, loader-type landfill compactors, combustion-engine driven counterbalanced lift trucks, compaction machines (non-vibrating rollers),paver-finishers, hydraulic power packs, P ≤ 55,104,101,
 P &gt; 55,85 + 11 1g P,82 + 11 1g P,
Mobile cranes,P ≤ 55,104,101,
 P &gt; 55,85 + 11 1g P,82 + 11 1g P 101,
Excavators, builders' hoists for the transport of goods, construction winches, motor hoes, P ≤ 15,96,93,
 P &gt; 15,83 + 11 1g P,80 + 11 1g P,
Hand-held concrete-breakers and picks, m ≤ 15,107,105,
15&lt; m &lt; 30,94 + 11 1g m,92 + 11 1g m,
 m ≥ 30,96 + 11 1g m,94 + 11 1g m,
Tower cranes,,98 + 1g P,96 + 1g P,
Welding and power generators,P el ≤ 2,97 + 1g P el,95 + 1g P el,
2 &lt; P el ≤ 10,98 + 1g P el,96 + 1g P el,
10 &gt; P el,97 + 1g P el,95 + 1g P el,
Compressors,P ≤ 15,99,97,
P &gt; 15,97 + 2 1g P el,95 + 2 1g P el,
Lawnmowers, lawn trimmers/lawn-edge trimmers, L ≤ 50,96,96,
50 &lt; L ≤ 70,100,98,
70 &lt; L ≤ 120,100,100,
 L &gt; 120,105,105,
The permissible sound power level shall be rounded up or down to the nearest integer number (less than 0.5, use lower number; greater than or equal to 0.5, use higher number).,

1,1,0,1.5m,
2,0.7,0.7,1.5m,
3,0,1,1.5m,
4,-0.7,0.7,1.5m,
5,-1,0,1.5m,
6,-0.7,-0.7,1.5m,
7,0,-1,1.5m,
8,0.7,-0.7,1.5m,
9,0.65,0.27,0.71 r,
10,-0.27,0.65,0.71 r,
11,-0.65,-0.27,0.71 r,
12,0.27,-0.65,0.71 r,

m &lt; 10,2m,0.75m,
m≥ 10,4m,1.50m,
conveying system,at least 10% of maximum value,
spreading system,at least 40% of maximum value,
tamper (speed, stroke),at least 50% of maximum value,
vibrators (speed, unbalance moment),at least 50% of maximum value,
pressure bars (frequency, pressure),at least 50 per cent of maximum value,
— length:,150 mm±0.5 mm,
— nominal external diameter:,90 mm + 0.3/- 0 mm,
— nominal depth:,6.7 mm + 0.9/- 0 mm,

 m &lt; 10,2,0,75,
 m ≥ 10,4,1,50,