Regulation 5
SCHEDULEN.I.Table to be substituted for the Table to Regulation 8 (Application to material change of use) to the principal Regulations.
Table to Regulation 8 (Application to material change of use)
Part | Cases | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
I | II | III | IV | V | VI | VII | VIII | IX | X | XI | XII | ||
A | Interpretation and general | * | * | * | * | * | * | * | * | * | * | * | * |
B | Materials and workmanship | *1 | *1 | – | *1 | – | – | – | – | *1 | *1 | *1 | * |
C | Site preparation and resistance to contaminants and moisture | *2 | *2 | *2 | *2 | *2 | *2 | *2 | *2 | *2 | *2 | *2 | *2 |
D | Structure | *3 | *3 | *3 | *3 | *3 | *3 | *3 | *3 | *3 | *3 | *3 | * |
E | Fire safety | *4 | * | *5 | * | *5 | *5 | *5 | *5 | * | *6 | *6 | * |
F | Conservation of fuel and power | *7 | *7 | *7 | *7 | *7 | *7 | *7 | *7 | *7 | *7 | *7 | *7 |
G | Resistance to the passage of sound | *8 | *9 | *9 | – | *10 | – | – | – | *9 | *9 | *9 | * |
H | Stairs, ramps, guarding and protection from impact | – | – | – | – | – | – | – | – | – | – | – | * |
J | Solid waste in buildings | * | * | * | * | * | – | – | – | * | * | * | * |
K | Ventilation | * | * | * | * | * | – | – | – | * | * | * | * |
L | Combustion appliances and fuel storage systems | *11 | *11 | *11 | *11 | *11 | – | – | – | *11 | – | –- | *11 |
M | Physical infrastructure for high-speed electronic communications networks | – | – | – | – | – | – | – | – | – | – | – | – |
N | Drainage | – | – | – | – | – | – | – | – | – | – | – | – |
P | Sanitary appliances, unvented hot water storage systems and reducing the risk of scalding | *12 | *12 | *12 | *12 | *12 | – | – | – | *12 | *12 | *12 | *12 |
R | Access to and use of buildings | – | – | *13 | *13 | *13 | *13 | – | – | – | – | – | * |
V | Glazing | * | * | – | – | – | – | – | – | * | – | – | – |
Notes to Table to Regulation 8 (Application to material change of use)N.I.
* Denotes Parts which apply.
– Denotes Parts which do not apply.
1 Regulation 23(2) only in Part B . In Cases X and X1 where the building created is a hostel, hotel or boarding house, all of Part B shall not apply.
2 All regulations except regulation 27 in Part C.
3 Part D shall apply to those parts of the building affected by any increase in imposed loading resulting from the change of use.
4 All regulations except regulation 37A and 37B in Part E.
5 All regulations except regulation 37B in Part E.
6. Regulation 37B in Part E in relation to halls of residence buildings only.
7 Regulation 39 only in Part F.
8 Regulations 49 and 50 only in Part G.
9 Regulations 49, 50 and 51 only in Part G.
10 Regulation 52 in Part G in relation to school buildings only.
11 Regulations 70, 71 and 73 only in Part L.
12 All regulations except regulation 88 in Part P.
13 In the application of Part R—
(a)when satisfying the reasonable provision requirements for access and that access is by means of stairs and/or ramps, such stairs and/or ramps shall also satisfy the relevant requirements of Part H;
(b)where the change of use is only to part of a building—
(i)Part R shall apply to that part and any sanitary accommodation provided in or in connection with that part; and
(ii)access to that part shall be provided by making reasonable provision for either independent access or suitable access through the building.