1 ≤ f &lt; 25 Hz,2.0 × 10 4,2.0 × 10 4,
25 ≤ f &lt; 50 Hz,5.0 × 10 5 /f,2.0 × 10 4,
50 Hz ≤ f &lt; 1.64 kHz,5.0 × 10 5 /f,1.0 × 10 6 /f,
1.64 ≤ f &lt; 3 kHz,5.0 × 10 5 /f,6.1 ×10 2,
3 kHz ≤ f ≤ 10 MHz,1.7 × 10 2,6.1 ×10 2,
Exposure levels not exceeding the ALs will be compliant with:,Tables ELV2 and ELV3 ,

1 ≤ f &lt; 8 Hz,2.0 × 10 5 /f 2,3.0 × 10 5 /f,9.0 × 10 5 /f,
8 ≤ f &lt; 25 Hz,2.5 × 10 4 /f,3.0 × 10 5 /f,9.0 × 10 5 /f,
25 ≤ f &lt; 300 Hz,1.0 × 10 3,3.0 × 10 5 /f,9.0 × 10 5 /f,
300 Hz ≤ f &lt; 3 kHz,3.0 × 10 5 /f,3.0 × 10 5 /f,9.0 × 10 5 /f,
3 kHz ≤ f ≤ 10 MHz,1.0 × 10 2,1.0 × 10 2,3.0 × 10 2,
Exposure levels not exceeding the ALs will be compliant with:,At and below 400 Hz: the sensory effect ELVs in Table ELV3,The health effect ELVs in Table ELV2,
Above 400 Hz: the health effect ELVs in Table ELV2,

100 kHz ≤ f &lt; 1 MHz,6.1 × 10 2,2.0 × 10 6 /f,-,
1 ≤ f &lt; 10 MHz,6.1 × 10 8 /f,2.0 × 10 6 /f,-,
10 ≤ f &lt; 400 MHz,61,0.2,-,
400 MHz ≤ f &lt; 2 GHz,3 × 10 -3 f 1/2,1.0 × 10 -5 f 1/2,-,
2 ≤ f &lt; 6 GHz,1.4 × 10 2,4.5 × 10 -1,-,
6 ≤ f ≤ 300 GHz,1.4 × 10 2,4.5 × 10 -1,50,
Exposure levels not exceeding the ALs will be compliant with:,Up to 6 GHz: the health effect ELVs in Table ELV4  6 – 300 GHz: the health effect ELV in Table ELV6 ,The health effect ELV in Table ELV6,

10 ≤ f ≤ 110 MHz,100,
Exposure levels not exceeding the ALs will be compliant with:,The health effect ELV in Table ELV4 - localised SAR in the limbs,

Head and trunk,2,
Limbs,8,
,Health effect ELV – magnetic flux density (B 0 ) [T],
Any part of the body,8,

1 Hz ≤ f &lt; 3 kHz,1.1,
3 kHz ≤ f ≤ 10 MHz,3.8 × 10 -4 f,

1 ≤ f &lt; 10 Hz,0.7/f,
10 ≤ f &lt; 25 Hz,0.07,
25 ≤ f ≤ 400 Hz,0.0028 f,

Whole body,0.4 (averaged SAR in the body),
Head and trunk,10 (localised SAR in the head and trunk),
Limbs,20 (localised SAR in the limbs),

300 MHz ≤ f ≤ 6 GHz,10,

6 GHz ≤ f ≤ 300 GHz,50,

up to 2.5 kHz,1.0,
2.5 ≤ f &lt; 100 kHz,0.4 f,
100 ≤ f ≤10,000 kHz,40,

Interference with active implanted medical devices,0.5,
Attraction and projectile risk in the fringe field of high field strength sources (&gt; 100 mT),3,

100 kHz ≤ f &lt; 110 MHz,40,