The Quality of Bathing Water Regulations (Northern Ireland) 2008

Sampling equipmentN.I.

4.—(1) The Department shall only use sampling bottles which—

(a)have been—

(i)sterilised in an autoclave for at least 15 minutes at 121 degrees Celsius;

(ii)dry sterilised at no lower than 160 degrees Celsius and no higher than 170 degrees Celsius for at least one hour; or

(iii)irradiated by their manufacturer and not used previously;

(b)are of a size which allows sufficient water to be taken and analysed for the presence of Intestinal enterococci and Escherichia coli; and

(c)are made of transparent and colourless material.

(2) The Department shall—

(a)use aseptic techniques to maintain the sterility of the sample bottles; and

(b)clearly identify every sample taken by marking in indelible ink the sample bottle and associated paperwork.