xmlns:atom="http://www.w3.org/2005/Atom"
  1. Introductory Text

  2. Part I Interpretation and General

    1. 1.Citation and commencement

    2. 2.Interpretation

    3. 3.Application

  3. Part II Integrity of Installations

    1. 4.General duty

    2. 5.Design of an installation

    3. 6.Work to an installation

    4. 7.Operation of an installation

    5. 8.Maintenance of integrity

    6. 9.Reporting of danger to an installation

    7. 10.Decommissioning and dismantlement

  4. Part III Further Requirements Relating to Installations

    1. 11.Helicopter landing area

    2. 12.Additional requirements

  5. Part IV Wells

    1. 13.General duty

    2. 14.Assessment of conditions below ground

    3. 15.Design with a view to suspension and abandonment

    4. 16.Materials

    5. 17.Well control

    6. 18.Arrangements for examination

    7. 19.Provision of drilling etc. information

    8. 20.Co-operation

    9. 21.Information, instruction, training and supervision

  6. Part V Miscellaneous

    1. 22.Defence

    2. 23.Certificates of exemption

    3. 24.Transitional provision

    4. 25.Repeal of section 3 of the Mineral Workings (Offshore Installations) Act 1971

    5. 26.Modifications of statutory provisions

    6. 27.Revocation

  7. Signature

    1. SCHEDULE 1

      Additional requirements

      1. 1.Organisation of the installation

      2. 2.An installation shall be kept sufficiently clean, with any hazardous...

      3. 3.Arrangements shall exist for the collection at source and removal,...

      4. 4.Workstations must be designed and constructed with a view to...

      5. 5.A supply of fresh or purified air shall be maintained...

      6. 6.If a mechanical ventilation system is used, it must be...

      7. 7.If air-conditioning or mechanical ventilation systems are used, they must...

      8. 8.Any deposit or dirt likely to create an immediate danger...

      9. 9.Room temperature

      10. 10.The temperature in rest areas, changing rooms, rooms containing facilities...

      11. 11.Sunlight let into workplaces via any window or skylight shall...

      12. 12.Floors, walls and ceilings of rooms

      13. 13.Enclosed workplaces must be adequately insulated against heat, bearing in...

      14. 14.The surfaces of floors, walls and ceilings in rooms must...

      15. 15.Transparent or translucent surfaces

      16. 16.Roofs

      17. 17.Natural and artificial lighting

      18. 18.Workplaces must, as far as possible, receive sufficient natural light...

      19. 19.Lighting installations in workplaces and in passageways must be placed...

      20. 20.Workplaces in which persons are especially exposed to risks in...

      21. 21.Windows and skylights

      22. 22.It must be possible to clean windows and skylights without...

      23. 23.Doors and gates

      24. 24.Transparent doors must be appropriately marked at a conspicuous level....

      25. 25.Swing doors and gates must be transparent or have see-through...

      26. 26.Sliding doors must be fitted with a safety device to...

      27. 27.Doors and gates opening upwards must be fitted with a...

      28. 28.Doors for pedestrians must be provided in the immediate vicinity...

      29. 29.Power-operated doors and gates must function without risk of accident...

      30. 30.When chains or similar devices are used to prevent access...

      31. 31.Traffic routes

      32. 32.Traffic routes must be sufficient in number, in suitable positions,...

      33. 33.If means of transport are used on traffic routes, a...

      34. 34.Sufficient clearance must be allowed between vehicle traffic routes and...

      35. 35.Traffic routes must be clearly identified for the protection of...

      36. 36.Danger areas

      37. 37.Room dimensions and air space in rooms — freedom of movement in the workstation

      38. 38.The dimensions of the unoccupied area at the workstation must...

      39. 39.Rest rooms

      40. 40.Paragraph 39 does not apply if the workers are employed...

      41. 41.Rest rooms must be large enough and equipped with an...

      42. 42.If working hours are regularly and frequently interrupted and there...

      43. 43.Appropriate measures should be taken for the protection of non-smokers...

      44. 44.Outdoor workplaces

      45. 45.Workplaces outdoors must be adequately lit by artificial lighting if...

      46. 46.When workers are employed at workstations outdoors, such workstations must...

      47. 47.Pregnant women and nursing mothers

      48. 48.People with disabilities

      49. 49.Sanitary facilities

      50. 50.Changing rooms must be easily accessible, be of sufficient capacity...

      51. 51.Changing rooms must be sufficiently large and have facilities to...

      52. 52.If circumstances so require, lockers for work clothes must be...

      53. 53.Provision must be made to enable wet work clothes to...

      54. 54.Provision must be made for separate changing rooms or separate...

      55. 55.If changing rooms are not required under paragraph 49, each...

      56. 56.Showers and washing facilities

      57. 57.Lavatories and washbasins

      58. 58.Provision must be made for separate lavatories or separate use...

      59. 59.Accommodation

      60. 60.Accommodation must contain sufficient beds or bunks for the number...

      61. 61.Any room designated as sleeping accommodation— (a) must not be...

      62. 62.Accommodation must include a sufficient number of showers and washing...

      63. 63.Showers must be sufficiently spacious to permit each worker to...

      64. 64.Accommodation must be equipped with a sufficient number of lavatories...

      65. 65.Where there are both men and women on an installation...

      66. 66.Accommodation and its plant must be maintained to adequate standards...

      67. 67.Noise and vibration of plant

    2. SCHEDULE 2

      Modification of the Offshore Installations (Safety Case) Regulations (Northern Ireland) 1993

      1. 1.In regulation 2 of the 1993 Regulations—

      2. 2.There shall be substituted for paragraph (4) of regulation 7...

      3. 3.There shall be added to regulation 10 of the 1993...

      4. 4.After regulation 12 of the 1993 Regulations there shall be...

      5. 5.After paragraph (2) of regulation 14 of the 1993 Regulations...

      6. 6.In regulation 14(3) of the 1993 Regulations, for the words...

      7. 7.After regulation 14 of the 1993 Regulations there shall be...

      8. 8.After paragraph 9 of Schedule 2 to the 1993 Regulations...

      9. 9.After paragraph 7 of Schedule 3 to the 1993 Regulations...

      10. 10.In Schedule 6 to the 1993 Regulations there shall be...

      11. 11.After Schedule 6 to the 1993 Regulations there shall be...

      12. 12.After Schedule 8 to the 1993 Regulations there shall be...

    3. SCHEDULE 3

      Revocation

  8. Explanatory Note