Search Legislation

The Town and Country Planning (General Permitted Development) (Amendment) (England) Order 2011

 Help about what version

What Version

  • Latest available (Revised)
  • Original (As made)

Status:

This is the original version (as it was originally made). This item of legislation is currently only available in its original format.

Article 2(4)

SCHEDULE

This schedule has no associated Explanatory Memorandum

Part 40INSTALLATION OF DOMESTIC MICROGENERATION EQUIPMENT

Class A

Permitted development

A.  The installation, alteration or replacement of solar PV or solar thermal equipment on—

(a)a dwellinghouse or a block of flats; or

(b)a building situated within the curtilage of a dwellinghouse or a block of flats.

Development not permitted

A.1.  Development is not permitted by Class A if—

(a)the solar PV or solar thermal equipment would protrude more than 200 millimetres beyond the plane of the wall or the roof slope when measured from the perpendicular with the external surface of the wall or roof slope;

(b)it would result in the highest part of the solar PV or solar thermal equipment being higher than the highest part of the roof (excluding any chimney);

(c)in the case of land within a conservation area or which is a World Heritage Site, the solar PV or solar thermal equipment would be installed on a wall which fronts a highway;

(d)the solar PV or solar thermal equipment would be installed on a site designated as a scheduled monument; or

(e)the solar PV or solar thermal equipment would be installed on a building within the curtilage of the dwellinghouse or block of flats if the dwellinghouse or block of flats is a listed building.

Conditions

A.2.  Development is permitted by Class A subject to the following conditions—

(a)solar PV or solar thermal equipment shall, so far as practicable, be sited so as to minimise its effect on the external appearance of the building;

(b)solar PV or solar thermal equipment shall, so far as practicable, be sited so as to minimise its effect on the amenity of the area; and

(c)solar PV or solar thermal equipment no longer needed for microgeneration shall be removed as soon as reasonably practicable.

Class B

Permitted development

B.  The installation, alteration or replacement of stand alone solar within the curtilage of a dwellinghouse or a block of flats.

Development not permitted

B.1.  Development is not permitted by Class B if—

(a)in the case of the installation of stand alone solar, the development would result in the presence within the curtilage of more than one stand alone solar;

(b)any part of the stand alone solar—

(i)would exceed four metres in height;

(ii)would, in the case of land within a conservation area or which is a World Heritage Site, be installed so that it is nearer to any highway which bounds the curtilage than the part of the dwellinghouse or block of flats which is nearest to that highway;

(iii)would be installed within five metres of the boundary of the curtilage;

(iv)would be installed within the curtilage of a listed building; or

(v)would be installed on a site designated as a scheduled monument; or

(c)the surface area of the solar panels forming part of the stand alone solar would exceed nine square metres or any dimension of its array (including any housing) would exceed three metres.

Conditions

B.2.  Development is permitted by Class B subject to the following conditions—

(a)stand alone solar shall, so far as practicable, be sited so as to minimise its effect on the amenity of the area; and

(b)stand alone solar which is no longer needed for microgeneration shall be removed as soon as reasonably practicable.

Class C

Permitted development

C.  The installation, alteration or replacement of a ground source heat pump within the curtilage of a dwellinghouse or a block of flats.

Class D

Permitted development

D.  The installation, alteration or replacement of a water source heat pump within the curtilage of a dwellinghouse or a block of flats.

Class E

Permitted development

E.  The installation, alteration or replacement of a flue, forming part of a biomass heating system, on a dwellinghouse or a block of flats.

Development not permitted

E.1  Development is not permitted by Class E if—

(a)the height of the flue would exceed the highest part of the roof by one metre or more; or

(b)in the case of land within a conservation area or which is a World Heritage Site, the flue would be installed on a wall or roof slope which fronts a highway.

Class F

Permitted development

F.  The installation, alteration or replacement of a flue, forming part of a combined heat and power system, on a dwellinghouse or a block of flats.

Development not permitted

F.1  Development is not permitted by Class F if—

(a)the height of the flue would exceed the highest part of the roof by one metre or more; or

(b)in the case of land within a conservation area or which is a World Heritage Site, the flue would be installed on a wall or roof slope which fronts a highway.

Class G

Permitted Development

G.  The installation, alteration or replacement of an air source heat pump—

(a)on a dwellinghouse or a block of flats; or

(b)within the curtilage of a dwellinghouse or a block of flats, including on a building within that curtilage.

Development not permitted

G.1   Development is not permitted by Class G unless the air source heat pump complies with the MCS Planning Standards or equivalent standards.

G.2.  Development is not permitted by Class G if—

(a)in the case of the installation of an air source heat pump, the development would result in the presence of more than one air source heat pump on the same building or within the curtilage of the building or block of flats;

(b)in the case of the installation of an air source heat pump, a wind turbine is installed on the same building or within the curtilage of the dwellinghouse or block of flats;

(c)in the case of the installation of an air source heat pump, a stand alone turbine is installed within the curtilage of the dwellinghouse or block of flats;

(d)the volume of the air source heat pump’s outdoor compressor unit (including any housing) would exceed 0.6 cubic metres;

(e)any part of the air source heat pump would be installed within one metre of the boundary of the curtilage of the dwellinghouse or block of flats;

(f)the air source heat pump would be installed on a pitched roof;

(g)the air source heat pump would be installed on a flat roof where it would be within one metre of the external edge of that roof;

(h)the air source heat pump would be installed on a site designated as a scheduled monument;

(i)the air source heat pump would be installed on a building or on land within the curtilage of the dwellinghouse or the block of flats if the dwellinghouse or the block of flats is a listed building;

(j)in the case of land within a conservation area or which is a World Heritage Site the air source heat pump—

(i)would be installed on a wall or a roof which fronts a highway; or

(ii)would be installed so that it is nearer to any highway which bounds the curtilage than the part of the dwellinghouse or block of flats which is nearest to that highway; or

(k)in the case of land, other than land within a conservation area or which is a World Heritage Site, the air source heat pump would be installed on a wall of a dwellinghouse or block of flats if—

(i)that wall fronts a highway; and

(ii)the air source heat pump would be installed on any part of that wall which is above the level of the ground storey.

Conditions

G.3.  Development is permitted by Class G subject to the following conditions—

(a)the air source heat pump shall be used solely for heating purposes;

(b)the air source heat pump shall, so far as practicable, be sited so as to minimise its effect on the external appearance of the building;

(c)the air source heat pump shall, so far as practicable, be sited so as to minimise its effect on the amenity of the area; and

(d)the air source heat pump when no longer needed for microgeneration shall be removed as soon as reasonably practicable.

Class H

Permitted Development

H.  The installation, alteration or replacement of a wind turbine on—

(a)a detached dwellinghouse; or

(b)a detached building situated within the curtilage of a dwellinghouse or a block of flats.

Development not permitted

H.1.  Development is not permitted by Class H unless the wind turbine complies with the MCS Planning Standards or equivalent standards.

H.2  Development is not permitted by Class H if—

(a)in the case of the installation of a wind turbine the development would result in the presence of more than one wind turbine on the same building or within the curtilage;

(b)in the case of the installation of a wind turbine, a stand alone wind turbine is installed within the curtilage of the dwellinghouse or the block of flats;

(c)in the case of the installation of a wind turbine, an air source heat pump is installed on the same building or within its curtilage;

(d)the highest part of the wind turbine (including blades) would either—

(i)protrude more than three metres above the highest part of the roof (excluding the chimney); or

(ii)exceed more than 15 metres in height,

whichever is the lesser;

(e)the distance between ground level and the lowest part of any blade of the wind turbine would be less than five metres;

(f)any part of the wind turbine (including blades) would be positioned so that it would be within five metres of any boundary of the curtilage of the dwellinghouse or the block of flats;

(g)the swept area of any blade of the wind turbine would exceed 3.8 square metres;

(h)the wind turbine would be installed on safeguarded land;

(i)the wind turbine would be installed on a site designated as a scheduled monument;

(j)the wind turbine would be installed within the curtilage of a building which is a listed building;

(k)in the case of land within a conservation area, the wind turbine would be installed on a wall or roof slope of—

(i)the detached dwellinghouse; or

(ii)a building within the curtilage of the dwellinghouse or block of flats,

which fronts a highway; or

(l)the wind turbine would be installed on article 1(5) land other than land within a conservation area.

Conditions

H.3.  Development is permitted by Class H subject to the following conditions—

(a)the blades of the wind turbine shall be made of non reflective materials;

(b)the wind turbine shall, so far as practicable, be sited so as to minimise its effect on the external appearance of the building;

(c)the wind turbine shall, so far as practicable, be sited so as to minimise its effect on the amenity of the area; and

(d)the wind turbine when no longer needed for microgeneration shall be removed as soon as reasonably practicable.

Class I

Permitted Development

I.  The installation, alteration or replacement of a stand alone wind turbine within the curtilage of a dwellinghouse or a block of flats.

Development not permitted

I.1.  Development is not permitted by Class I unless the stand alone wind turbine complies with the MCS Planning Standards or equivalent standards.

I.2  Development is not permitted by Class I if—

(a)in the case of the installation of a stand alone wind turbine, the development would result in the presence of more than one stand alone wind turbine within the curtilage of the dwellinghouse or block of flats;

(b)in the case of the installation of a stand alone wind turbine, a wind turbine is installed on the dwellinghouse or on a building within the curtilage of the dwellinghouse or the block of flats;

(c)in the case of the installation of a stand alone wind turbine, an air source heat pump is installed on the dwellinghouse or block of flats or within the curtilage of the dwellinghouse or block of flats;

(d)the highest part of the stand alone wind turbine would exceed 11.1 metres in height;

(e)the distance between ground level and the lowest part of any blade of the stand alone wind turbine would be less than five metres;

(f)any part of the stand alone wind turbine (including blades) would be located in a position which is less than a distance equivalent to the overall height (including blades) of the stand alone wind turbine plus 10 % of its height when measured from any point along the boundary of the curtilage;

(g)the swept area of any blade of the stand alone wind turbine exceeds 3.8 square metres;

(h)the stand alone wind turbine would be installed on safeguarded land;

(i)the stand alone wind turbine would be installed on a site designated as a scheduled monument;

(j)the stand alone wind turbine would be installed within the curtilage of a building which is a listed building;

(k)in the case of land within a conservation area, the stand alone wind turbine would be installed so that it is nearer to any highway which bounds the curtilage than the part of the dwellinghouse or block of flats which is nearest to that highway; or

(l)the stand alone wind turbine would be installed on article 1(5) land other than land within a conservation area.

Conditions

I.3.  Development is permitted by Class I subject to the following conditions—

(a)the blades of the stand alone wind turbine shall be made of non reflective materials;

(b)the stand alone wind turbine shall, so far as practicable, be sited so as to minimise its effect on the amenity of the area; and

(c)the stand alone wind turbine when no longer needed for microgeneration shall be removed as soon as reasonably practicable.

Interpretation of Part 40

J.  For the purposes of Part 40—

“aerodrome”—

(a)

means any area of land or water designed, equipped, set apart, or commonly used for affording facilities for the landing and departure of aircraft; and

(b)

includes any area or space, whether on the ground, on the roof of a building or elsewhere, which is designed, equipped or set apart for affording facilities for the landing and departure of aircraft capable of descending or climbing vertically; but

(c)

does not include any area the use of which for affording facilities for the landing and departure of aircraft has been abandoned and has not been resumed;

“block of flats” means a building which consists wholly of flats;

“detached dwellinghouse” or “detached building” means a dwellinghouse or building, as the case may be, which does not share a party wall with a neighbouring building;

“microgeneration” has the same meaning as in section 82(6) of the Energy Act

2004(1);

MSC Planning Standards” means the product and installation standards for air source heat pumps and wind turbines specified in Microgeneration Certification Scheme MCS 020(2);

“safeguarded land” means land which—

(a)

is necessary to be safeguarded for aviation or defence purposes; and

(b)

has been notified as such, in writing, to the Secretary of State by an aerodrome operator, NATS (EN ROUTE) PLC or the Secretary of State for Defence for the purposes of this Part;

“solar PV” means solar photovoltaics;

“stand alone solar” means solar PV or solar thermal equipment which is not installed on a building;

“stand alone wind turbine” means a wind turbine which is not fixed to a building.

(2)

Issue 1.0 dated 19 August 2011 published by Gemserv Limited

Back to top

Options/Help

Print Options

Close

Legislation is available in different versions:

Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.

Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.

Close

Opening Options

Different options to open legislation in order to view more content on screen at once

Close

Explanatory Memorandum

Explanatory Memorandum sets out a brief statement of the purpose of a Statutory Instrument and provides information about its policy objective and policy implications. They aim to make the Statutory Instrument accessible to readers who are not legally qualified and accompany any Statutory Instrument or Draft Statutory Instrument laid before Parliament from June 2004 onwards.

Close

More Resources

Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as enacted version that was used for the print copy
  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • correction slips
  • links to related legislation and further information resources
Close

Impact Assessments

Impact Assessments generally accompany all UK Government interventions of a regulatory nature that affect the private sector, civil society organisations and public services. They apply regardless of whether the regulation originates from a domestic or international source and can accompany primary (Acts etc) and secondary legislation (SIs). An Impact Assessment allows those with an interest in the policy area to understand:

  • Why the government is proposing to intervene;
  • The main options the government is considering, and which one is preferred;
  • How and to what extent new policies may impact on them; and,
  • The estimated costs and benefits of proposed measures.
Close

More Resources

Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as made version that was used for the print copy
  • correction slips

Click 'View More' or select 'More Resources' tab for additional information including:

  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • links to related legislation and further information resources