Commission Implementing Regulation (EU) 2018/2066Show full title

Commission Implementing Regulation (EU) 2018/2066 of 19 December 2018 on the monitoring and reporting of greenhouse gas emissions pursuant to Directive 2003/87/EC of the European Parliament and of the Council and amending Commission Regulation (EU) No 601/2012 (Text with EEA relevance)

B.1. Installation level quantification U.K.

Each operator shall calculate the emissions by taking into account the potential CO2 emissions from all emission relevant processes at the installation, as well as the amount of CO2 captured and transferred to the transport network, using the following formula:

Ecapture installation = Tinput + Ewithout capture – Tfor storage

Where:

Ecapture installation

=

Total greenhouse gas emissions of the capture installation;

Tinput

=

Amount of CO2 transferred to the capture installation, determined in accordance with Article 40 to 46 and Article 49.

Ewithout capture

=

Emissions of the installation assuming the CO2 were not captured, meaning the sum of the emissions from all other activities at the installation, monitored in accordance with relevant sections of Annex IV;

Tfor storage

=

Amount of CO2 transferred to a transport network or a storage site, determined in accordance with Article 40 to 46 and Article 49.

In cases where CO2 capture is carried out by the same installation as the one from which the captured CO2 originates, the operator shall use zero for Tinput.

In cases of stand-alone capture installations, the operator shall consider Ewithout capture to represent the amount of emissions that occur from other sources than the CO2 transferred to the installation for capture. The operator shall determine those emissions in accordance with this Regulation.

In the case of stand-alone capture installations, the operator of the installation transferring CO2 to the capture installation shall deduct the amount Tinput from the emissions of its installation in accordance with Article 49.