ANNEX IVU.K. Activity-specific monitoring methodologies related to installations (Article 20(2))

21.DETERMINATION OF GREENHOUSE GAS EMISSIONS FROM CO2 CAPTURE ACTIVITIES FOR THE PURPOSES OF TRANSPORT AND GEOLOGICAL STORAGE IN A STORAGE SITE PERMITTED UNDER DIRECTIVE 2009/31/ECU.K.

B. Quantification of transferred and emitted CO2 amounts U.K.

B.1. Installation level quantification U.K.

Each operator shall calculate the emissions by taking into account the potential CO2 emissions from all emission relevant processes at the installation, as well as the amount of CO2 captured and transferred to the transport network, using the following formula:

Ecapture installation = Tinput + Ewithout capture – Tfor storage

Where:

Ecapture installation

=

Total greenhouse gas emissions of the capture installation;

Tinput

=

Amount of CO2 transferred to the capture installation, determined in accordance with Article 40 to 46 and Article 49.

Ewithout capture

=

Emissions of the installation assuming the CO2 were not captured, meaning the sum of the emissions from all other activities at the installation, monitored in accordance with relevant sections of Annex IV;

Tfor storage

=

Amount of CO2 transferred to a transport network or a storage site, determined in accordance with Article 40 to 46 and Article 49.

In cases where CO2 capture is carried out by the same installation as the one from which the captured CO2 originates, the operator shall use zero for Tinput.

In cases of stand-alone capture installations, the operator shall consider Ewithout capture to represent the amount of emissions that occur from other sources than the CO2 transferred to the installation for capture. The operator shall determine those emissions in accordance with this Regulation.

In the case of stand-alone capture installations, the operator of the installation transferring CO2 to the capture installation shall deduct the amount Tinput from the emissions of its installation in accordance with Article 49.