ANNEX I CU.K.Requirements for construction, testing, installation, and inspection

8.TYPE-APPROVAL OF RECORDING EQUIPMENT AND TACHOGRAPH CARDSU.K.

8.4 Interoperability certificate U.K.

(440)Interoperability tests are carried out by a single laboratory under the authority and responsibility of the European Commission.U.K.
(441)The laboratory shall register interoperability test requests introduced by manufacturers in the chronological order of their arrival.U.K.
(442)Requests will be officially registered only when the laboratory is in possession of:U.K.
  • the entire set of material and documents necessary for such interoperability tests,

  • the corresponding security certificate,

  • the corresponding functional certificate,

The date of the registration of the request shall be notified to the manufacturer.

(443)No interoperability tests shall be carried out by the laboratory, for recording equipment or tachograph cards that have not been granted a security certificate and a functional certificate, except in the exceptional circumstances described in Requirement 432.U.K.
(444)Any manufacturer requesting interoperability tests shall commit to leave to the laboratory in charge of these tests the entire set of material and documents which he provided to carry out the tests.U.K.
(445)The interoperability tests shall be carried out, in accordance with the provisions of Appendix 9 of this Annex, with respectively all the types of recording equipment or tachograph cards:U.K.
  • for which type approval is still valid or,

  • for which type approval is pending and that have a valid interoperability certificate.