ANNEX I CU.K.Requirements for construction, testing, installation, and inspection

Appendix 9

TYPE APPROVAL LIST OF MINIMUM REQUIRED TESTS U.K.

[F16. EXTERNAL REMOTE COMMUNICATION FACILITY TEST U.K.
No Test Description Related requirements
1. Administrative examination
1.1 Documentation Correctness of documentation
2. Visual inspection
2.1. Compliance with documentation
2.2. Identification / markings 225, 226
2.3 Materials 219 to 223
3. Functional tests
3.1 Remote communication for targeted roadside checks 4, 197 to 199
3.2 Recording and storing in data memory 91
3.3 Communication with Vehicle Unit Appendix 14 DSC_66 to DSC_70, DSC_71 to DSC_76
4. Environmental tests
4.1 Temperature

Verify functionality through:

  • Test according to ISO 16750-4, Chapter 5.1.1.2: Low temperature operation test (72 h @ – 20 °C)

    This test refers to IEC 60068-2-1: Environmental testing - Part 2-1: Tests - Test A: Cold

  • Test according to ISO 16750-4: Chapter 5.1.2.2: High temperature operation test (72 h @ 70 °C)

    This test refers to IEC 60068-2-2: Basic environmental testing procedures; part 2: tests; tests B: dry heat

  • Test according to ISO 16750-4: Chapter 5.3.2: Rapid change of temperature with specified transition duration (– 20 °C/70 °C, 20 cycles, dwell time 1 h at each temperature)

    A reduced set of tests (among those defined in section 3 of this table) can be carried out at the lower temperature, the higher temperature and during the temperature cycles

213
4.2 Protection against water and foreign bodies Test according to ISO 20653: Road vehicles – Degree of protection (IP code) – Protection of electrical equipment against foreign objects, water and access (targeted value IP40) 220, 221
5 EMC tests
5.1 Radiated emissions and susceptibility Compliance with Regulation ECE R10 218
5.2 Electrostatic discharge Compliance with ISO 10605:2008 + Technical Corrigendum:2010 + AMD1:2014: +/– 4 kV for contact and +/– 8 kV for air discharge 218
5.3 Conducted transient susceptibility on power supply

For 24V versions: compliance with ISO 7637-2 + ECE Regulation No. 10 Rev. 3:

  • pulse 1a: Vs=– 450V Ri=50 ohms

  • pulse 2a: Vs=+37V Ri=2 ohms

  • pulse 2b: Vs=+20V Ri=0,05 ohms

  • pulse 3a: Vs=– 150V Ri=50 ohms

  • pulse 3b: Vs=+150V Ri=50 ohms

  • pulse 4: Vs=– 16V Va=-12V t6=100ms

  • pulse 5: Vs=+120V Ri=2,2 ohms td=250ms

For 12V versions: compliance with ISO 7637-1 + ECE Regulation No. 10 Rev. 3:

  • pulse 1: Vs=-75V Ri=10 ohms

  • pulse 2a: Vs=+37V Ri=2 ohms

  • pulse 2b: Vs=+10V Ri=0,05 ohms

  • pulse 3a: Vs=– 112V Ri=50 ohms

  • pulse 3b: Vs=+75V Ri=50 ohms

  • pulse 4: Vs=– 6V Va=– 5V t6=15ms

  • pulse 5: Vs=+65V Ri=3ohms td=100ms

  • Pulse 5 shall be tested only for vehicle units designed to be installed in vehicles for which no external common protection against load dump is implemented

For load dump proposal, refer to ISO 16750-2, 4th edition, chapter 4.6.4.

218]