Commission Implementing Regulation (EU) 2016/799 of 18 March 2016 implementing Regulation (EU) No 165/2014 of the European Parliament and of the Council laying down the requirements for the construction, testing, installation, operation and repair of tachographs and their components (Text with EEA relevance)

CPR_072If a component failure prevents the transmission of valid data for a parameter, the error indicator as described in Table 38 should be used in place of that parameter's data. However, if the measured or calculated data has yielded a value that is valid yet exceeds the defined parameter range, the error indicator should not be used. The data should be transmitted using the appropriate minimum or maximum parameter value.U.K.
Table 38
dataRecords ranges
Range Name1 byte(Hex value)2 bytes(Hex value)4 bytes(Hex Value)ASCII
Valid signal00 to FA0000 to FAFF00000000 to FAFFFFFF1 to 254
Parameter specific indicatorFBFB00 to FBFFFB000000 to FBFFFFFFnone
Reserved range for future indicator bitsFC to FDFC00 to FDFFFC000000 to FDFFFFFFnone
Error indicatorFEFE00 to FEFFFE000000 to FEFFFFFF0
Not available or not requestedFFFF00 to FFFFFF000000 to FFFFFFFFFF