ANNEX I CRequirements for construction, testing, installation, and inspection
Appendix 8
CALIBRATION PROTOCOL
8.DATARECORDS FORMATS
8.1.Transmitted parameter ranges
CPR_072If a component failure prevents the transmission of valid data for a parameter, the error indicator as described in Table 38 should be used in place of that parameter's data. However, if the measured or calculated data has yielded a value that is valid yet exceeds the defined parameter range, the error indicator should not be used. The data should be transmitted using the appropriate minimum or maximum parameter value.
Table 38 | ||||
dataRecords ranges | ||||
Range Name | 1 byte(Hex value) | 2 bytes(Hex value) | 4 bytes(Hex Value) | ASCII |
---|---|---|---|---|
Valid signal | 00 to FA | 0000 to FAFF | 00000000 to FAFFFFFF | 1 to 254 |
Parameter specific indicator | FB | FB00 to FBFF | FB000000 to FBFFFFFF | none |
Reserved range for future indicator bits | FC to FD | FC00 to FDFF | FC000000 to FDFFFFFF | none |
Error indicator | FE | FE00 to FEFF | FE000000 to FEFFFFFF | 0 |
Not available or not requested | FF | FF00 to FFFF | FF000000 to FFFFFFFF | FF |