xmlns:atom="http://www.w3.org/2005/Atom" xmlns:atom="http://www.w3.org/2005/Atom"

ANNEX I CU.K. Requirements for construction, testing, installation, and inspection

Appendix 7

DATA DOWNLOADING PROTOCOLS U.K.

3.TACHOGRAPH CARDS DOWNLOADING PROTOCOLU.K.
3.3. Card Downloading U.K.
3.3.2 Sequence for un-signed data files U.K.
DDP_037 [F1The sequence to download EFs ICC, IC, Card_Certificate (or CardSignCertificate for DF Tachograph_G2), CA_Certificate and Link_Certificate (for DF Tachograph_G2 only) is as follows:] U.K.
CardDirectionIDE/IFDMeaning/Remarks
Select FileSelect by File identifiers
OK
Read BinaryIf the file contains more data than the buffer size of the reader or the card the command has to be repeated until the complete file is read.

File Data

OK

Store data to ESMaccording to 3.4 Data storage format

Note 1: Before selecting the Card_Certificate (or CardSignCertificate) EF, the Tachograph Application must be selected (selection by AID).U.K.

Note 2: Selecting and reading a file may also be performed in one step using a Read Binary command with a short EF identifier.U.K.