Please note that the date you requested in the address for this web page is not an actual date upon which a change occurred to this item of legislation. You are being shown the legislation from , which is the first date before then upon which a change was made.
Example of Basic Biprotocol ATR according to ISO/IEC 7816-3
Character | Value | Remarks |
---|---|---|
TS | ‘3Bh’ | Indicates direct convention. |
T0 | ‘85h’ | TD1 present; 5 historical bytes are presents. |
TD1 | ‘80h’ | TD2 present; T=0 to be used |
TD2 | ‘11h’ | TA3 present; T=1 to be used |
TA3 | ‘XXh’ (at least ‘F0h’) | Information Field Size Card ( IFSC) |
TH1 to TH5 | ‘XXh’ | Historical characters |