
A +++ , EEI ≥ 150,
A ++ ,125 ≤ EEI &lt; 150,
A + ,98 ≤ EEI &lt; 125,
A,90 ≤ EEI &lt; 98,
B,82 ≤ EEI &lt; 90,
C,75 ≤ EEI &lt; 82,
D,36 ≤ EEI &lt; 75,
E,34 ≤ EEI &lt; 36,
F,30 ≤ EEI &lt; 34,
G, EEI &lt; 30,
 Table 2 ,
 Weighting of primary solid fuel boiler and supplementary heater, for the purposes of Figure 1 of this Annex  ,
     Pr refers to the primary solid fuel boiler.    ,

0,0,0,
0,1,0,30,0,37,
0,2,0,55,0,70,
0,3,0,75,0,85,
0,4,0,85,0,94,
0,5,0,95,0,98,
0,6,0,98,1,00,
≥ 0,7,1,00,1,00,
 Table 3 ,
 Weighting of primary cogeneration solid fuel boiler and supplementary heater, for the purposes of Figure 2 of this Annex  ,
    The intermediate values are calculated by linear interpolation between the two adjacent values.    ,
     Pr refers to the primary solid fuel boiler.    ,

0,1,00,1,00,
0,1,0,70,0,63,
0,2,0,45,0,30,
0,3,0,25,0,15,
0,4,0,15,0,06,
0,5,0,05,0,02,
0,6,0,02,0,
≥ 0,7,0,0,
Tank volume = 45 × P r  × (1 – 2,7/ P r  ) or 300 litres whichever is higher, with P r  indicated in kW,
Tank volume = 20 × P r  with P r  indicated in kW,
For the preferred fuel P n  equals P r ,
Model identifier,
Stoking mode: [Manual: the boiler should be operated with a hot water storage tank of a volume of at least x litre/Automatic: it is recommended that the boiler be operated with a hot water storage tank of a volume of at least x litre],
Condensing boiler: [yes/no],
Solid fuel cogeneration boiler: [yes/no],Combination boiler: [yes/no],

Log wood, moisture content ≤ 25 %,[yes/no],[yes/no],
Chipped wood, moisture content 15-35 %,[yes/no],[yes/no],
Chipped wood, moisture content &gt; 35 %,[yes/no],[yes/no],
Compressed wood in the form of pellets or briquettes,[yes/no],[yes/no],
Sawdust, moisture content ≤ 50 %,[yes/no],[yes/no],
Other woody biomass,[yes/no],[yes/no],
Non-woody biomass,[yes/no],[yes/no],
Bituminous coal,[yes/no],[yes/no],
Brown coal (including briquettes),[yes/no],[yes/no],
Coke,[yes/no],[yes/no],
Anthracite,[yes/no],[yes/no],
Blended fossil fuel briquettes,[yes/no],[yes/no],
Other fossil fuel,[yes/no],[yes/no],
Blended biomass (30-70 %) and fossil fuel briquettes,[yes/no],[yes/no],
Other blend of biomass and fossil fuel,[yes/no],[yes/no],
Characteristics when operating with the preferred fuel:,
Seasonal space heating energy efficiency η s  [%]:,
Energy efficiency index EEI :,

Useful heat output,,Useful efficiency,
At rated heat output,P n ,x,x,kW,,At rated heat output,η n ,x,x,%,
At [30 %/50 %] of rated heat output, if applicable,P p ,[x,x/N.A.],kW,,At [30 %/50 %] of rated heat output, if applicable,η p ,[x,x/ N.A.],%,
For solid fuel cogeneration boilers: Electrical efficiency,,Auxiliary electricity consumption,
,At rated heat output,el max ,x,xxx,kW,
At rated heat output,η el,n ,x,x,%,,At [30 %/50 %] of rated heat output, if applicable,el min ,[x,xxx/ N.A.],kW,
,Of incorporated secondary emission abatement equipment, if applicable,[x,xxx/ N.A.],kW,
,In standby mode,P SB ,x,xxx,kW,
,
Contact details,Name and address of the supplier,
,

Energy efficiency index,The determined value shall not be lower than the declared value by more than 6 %. ,
