    ‘rated value’ means a value that is declared by the manufacturer. The 6 % uncertainty in the measurement represent the current acceptable testing laboratory error in measuring the declared parameters with the new measurement method used for the new labelling/ecodesign requirements including full and partial load cycles.    ,

Weighted annual energy consumption,The measured value shall not be greater than the rated value of AE C  by more than 6 %.,
Weighted energy consumption,The measured value shall not be greater than the rated value of E t  by more than 6 %.,
Weighted condensation efficiency,The measured value shall not be less than the rated value of C t  by more than 6 %.,
Weighted programme time,The measured value shall not be longer than the rated values of T t  by more than 6 %.,
Power consumption in off-mode and left-on mode,The measured value of power consumption P o  and P l  of more than 1,00 W shall not be greater than the rated value by more than 6 %. The measured value of power consumption P o  and P l  of less than or equal to 1,00 W shall not be greater than the rated value by more than 0,10 W.,
Duration of the left-on mode,The measured value shall not be longer than the rated value of T l  by more than 6 %.,