ANNEX IVActivity-specific monitoring methodologies related to installations (Article 20(2))

11.Manufacture of glass, glass fibre or mineral wool insulation material as listed in Annex I to Directive 2003/87/EC

B.Specific monitoring rules

Emissions from combustion, including flue gas scrubbing, and from process materials including coke, graphite and coal dust shall be monitored in accordance with section 1 of this Annex. Process emissions from raw materials shall be monitored in accordance with section 4 of Annex II. Carbonates to be taken into account include at least CaCO3, MgCO3, Na2CO3, NaHCO3, BaCO3, Li2CO3, K2CO3, and SrCO3. Only Method A shall be used.

The following tier definitions for the emission factor shall apply:

Tier 1

Stoichiometric ratios as listed in section 2 of Annex VI shall be used. The purity of relevant input materials shall be determined by means of industry best practice.

Tier 2

The determination of the amount of relevant carbonates in each relevant input material shall be carried out in accordance with Articles 32 to 35.

For the conversion factor, only tier 1 shall be applicable.